phoenix contact inc., usa page 1 / 5 http://www.phoenixcon.com feb 3, 2011 extract from the online catalog ? emd-fl-3v-690 order no.: 2885249 http://eshop.phoenixcontact.de/phoenix/treeviewclick.do?uid=2885249 ? ? monitoring relay for monitoring 3-phase voltages of 483897 v ac, undervoltage, window, phase sequence, phase failure, asymmetry, supply voltage can be selected using power module, 2 pdts ? commercial data gtin (ean) 4 017918 996482 sales group h216 pack 1 pcs. customs tariff 85364900 catalog page information page 655 (if-2009) product notes weee/rohs-compliant since: 12/03/2009 http:// www.download.phoenixcontact.com please note that the data given here has been taken from the online catalog. for comprehensive information and data, please refer to the user documentation. the general terms and conditions of use apply to internet downloads. product description increasingly higher demands are being placed on safety and system availability C across all sectors. processes are becoming more and more complex, not only in mechanical engineering and the chemical industry, but also in plant and automation technology. demands on power engineering are also increasing constantly. error-free and therefore cost-effective operation can only be achieved through continuous monitoring of important network and system parameters. electronic monitoring relays in the emd series are available for a wide range of monitoring tasks to avoid the consequences of errors or to keep them within limits.
emd-fl-3v-690 order no.: 2885249 http://eshop.phoenixcontact.de/phoenix/treeviewclick.do?uid=2885249 phoenix contact inc., usa page 2 / 5 http://www.phoenixcon.com feb 3, 2011 the operating states are indicated using colored leds, errors that may occur can be sent to a control system via a floating contact or can shut down a part of the system. some device versions are equipped with startup and response delays in order to briefly tolerate measured values outside the set monitoring range. technical data input data nominal input voltage u n 3 ~ 690 v maximum temperature coefficient < 0.1 %/k function undervoltage, window, asymmetry, phase sequence, phase failure min. setting range -30 % ... 20 % (from u n ) max. setting range -20 % ... 30 % (from u n ) min setting range of the voltage threshold value 483 v ac ... 828 v ac max. setting range of the voltage threshold value 552 v ac ... 897 v ac setting range for response delay 0.1 s ... 10 s basic accuracy 5 % (of scale end value) setting accuracy 5 % (of scale end value) repeat accuracy 2 % asymmetry 5 ? % ... 25% / off recovery time 500 ms contact side contact type 2 floating pdt contacts maximum switching voltage 250 v ac (in acc. with iec 60664-1) interrupting rating (ohmic load) max. 750 va (3 a/250 v ac, module aligned, 5 mm spacing) 1250 va (5 a/250 v ac, module not aligned, 5 mm spacing) output fuse 5 a (fast-blow) power supply supply voltage range 110 v ac ... 500 v ac (see power modules) general data width 45 mm height 90 mm depth 113 mm mechanical service life approx. 2 x 10 7 cycles operating mode 100% operating factor
emd-fl-3v-690 order no.: 2885249 http://eshop.phoenixcontact.de/phoenix/treeviewclick.do?uid=2885249 phoenix contact inc., usa page 3 / 5 http://www.phoenixcon.com feb 3, 2011 ambient temperature (operation) -25 c ... 55 c -25 c ... 40 c (corresponds to ul 508) ambient temperature (storage/transport) -25 c ... 70 c mounting position any assembly instructions on ts 35 profile rail acc. to en 60715 electromagnetic compatibility conformance with emc directive 2004/108/ec surge voltage category iii, basic insulation (as per en 50178) housing insulation material polyamide pa, self-extinguishing color green rated insulation voltage 600 v (according to en 50178) conformance ce-compliant ul, usa / canada ul/c-ul listed ul 508 connection data conductor cross section stranded min. 0.25 mm2 conductor cross section stranded max. 2.5 mm2 conductor cross section solid min. 0.5 mm2 conductor cross section solid max. 2.5 mm2 conductor cross section awg/kcmil min. 20 conductor cross section awg/kcmil max 14 stripping length 8 mm type of connection screw connection certificates / approvals certification cul listed, ul listed additional products item designation description general 2885281 emd-sl-ps45-110ac power modules, pluggable, for emd-fl-..., supply voltage: 88 v ac ... 121 v ac
emd-fl-3v-690 order no.: 2885249 http://eshop.phoenixcontact.de/phoenix/treeviewclick.do?uid=2885249 phoenix contact inc., usa page 4 / 5 http://www.phoenixcon.com feb 3, 2011 2885744 emd-sl-ps45-120ac power modules, pluggable, for emd-fl-..., supply voltage: 108 v ac ... 132 v ac 2885294 emd-sl-ps45-230ac power modules, pluggable, for emd-fl-..., supply voltage: 195 v ac ... 264 v ac 2885304 emd-sl-ps45-400ac power modules, pluggable, for emd-fl-..., supply voltage: 323...456 v ac 2885317 emd-sl-ps45-500ac power modules, pluggable, for emd-fl-..., supply voltage: 425...550 v ac diagrams/drawings block diagram
emd-fl-3v-690 order no.: 2885249 http://eshop.phoenixcontact.de/phoenix/treeviewclick.do?uid=2885249 phoenix contact inc., usa page 5 / 5 http://www.phoenixcon.com feb 3, 2011 address phoenix contact inc., usa 586 fulling mill road middletown, pa 17057,usa phone (800) 888-7388 fax (717) 944-1625 http://www.phoenixcon.com ? 2011 phoenix contact technical modifications reserved;
|