  phoenix contact deutschland gmbh page 1 / 6 http://www.phoenixcontact.de feb 8, 2011 extract from the online catalog ? ibs rl 480 mlr r dio6/1-lk2mbd order no.: 2734497 http://eshop.phoenixcontact.de/phoenix/treeviewclick.do?uid=2734497 ? ? electromechanical reversing load motor starter for interbus; fiber optic technology with 2 mbaud, inputs (24 v dc), integrated motor protection relay (220 v ac to 480 v ac; 8 a, maximum), sensor connection via 5-pos. m12 female connectors, rugged metal housing, ip67 protection ? commercial data gtin (ean) 4 017918 974190 note made-to-order sales group k525 pack 1 pcs. customs tariff 85389091 catalog page information page 415 (ax-2009) http:// www.download.phoenixcontact.com please note that the data given here has been taken from the online catalog. for comprehensive information and data, please refer to the user documentation. the general terms and conditions of use apply to internet downloads. technical data interface fieldbus system interbus name remote bus type of connection fiber optics transmission speed 2 mbaud
ibs rl 480 mlr r dio6/1-lk2mbd order no.: 2734497 http://eshop.phoenixcontact.de/phoenix/treeviewclick.do?uid=2734497 phoenix contact deutschland gmbh page 2 / 6 http://www.phoenixcontact.de feb 8, 2011 power supply for module electronics supply voltage 24 v dc supply voltage range 18.5 v dc ... 32 v dc (including ripple) ripple 3.6 v pp current consumption typ. 90 ma (plus power supply for sensors) mains connection name mains connection type of connection power-combicon with silver contacts designation connection point terminal strip; x11 and x12 number of positions 4 permissible conductor cross section 2.5 mm2 ... 4 mm2 operating voltage 230 v ac ... 480 v ac 10% (conductor voltage) max. current carrying capacity 20 a motor starter, output type of connection power-combicon number 1 designation connection point x10 number of positions 8 pg screw connection pg16 operating voltage 230 v ac ... 480 v ac frequency range 50 hz ... 60 khz nominal current range parameterizable 0.2 a ... 8 a (observe derating) utilization category on the basis of ac 3 switching rate 5 cycles per minute, maximum motor startup time 1 s motor monitoring parameterization via interbus overspeed tripping 40 a (after 1 second at i nom > 3.6 a) motor starter, brake continuous load current max. 1 a type of contact mechanical relay contact connection method power-combicon terminal strips connection voltage 12 v ac/dc ... 480 v ac/dc
ibs rl 480 mlr r dio6/1-lk2mbd order no.: 2734497 http://eshop.phoenixcontact.de/phoenix/treeviewclick.do?uid=2734497 phoenix contact deutschland gmbh page 3 / 6 http://www.phoenixcontact.de feb 8, 2011 digital inputs input name digital inputs number of inputs 6 type of connection m12 male connector connection method 3, 4-wire number of positions 5 input voltage 24 v dc (din en 61131-2) input voltage range "0" signal 0 v ... 5 v input voltage range "1" signal 11 v ... 30 v typical input current per channel 5 ma (for u s1 = 24 v) filter time 3 ms power supply for sensors u ini = u s1 minus 1 v 50 ma protected against inductive reverse voltages, electronically protected against short-circuiting digital outputs number of outputs 1 type of connection m12 male connector number of positions 5 output current 0.5 a minimum output voltage with nominal current u s1 minus 2 v type of protection electronic short-circuit/overload protection general data width 185.1 mm height 193 mm depth 138 mm weight 3.8 kg mounting type wall mounting ambient temperature (operation) 0 c ... 55 c ambient temperature (storage/transport) -25 c ... 70 c permissible humidity (operation) 100 % permissible humidity (storage/transport) 95 % (no condensation) air pressure (operation) 860 hpa ... 1080 hpa (up to 1500 m above mean sea level) air pressure (storage/transport) 660 hpa ... 1080 hpa (up to 3500 m above mean sea level) degree of protection ip67, when screwed together protection class i, iec 61140, en 61140, vde 0140-1 air and creepage distances according to en 50178: 1998
ibs rl 480 mlr r dio6/1-lk2mbd order no.: 2734497 http://eshop.phoenixcontact.de/phoenix/treeviewclick.do?uid=2734497 phoenix contact deutschland gmbh page 4 / 6 http://www.phoenixcontact.de feb 8, 2011 diagnostics messages mains failure, phase failure, blown fuse error message in diagnostic code (bus) and display by means of the e led on the motor starter motor connector not plugged in, motor temperature exceeded, thermistor line short-circuited error message in diagnostic code (bus) and display by means of the e led on the motor starter sensor supply failure error message in diagnostic code (bus) and display by means of the e led on the motor starter failure of the actuator supply error message in diagnostic code (bus) and display by means of the e led on the motor starter motor overcurrent error message in diagnostic code (bus) and display by means of the e led on the motor starter output stage cannot be controlled error message in diagnostic code (bus) and display by means of the e led on the motor starter module error during self test message to the master certificates / approvals certification cul listed, ul listed, vde-pzi accessories item designation description assembly 2731128 ibs rl ap mounting plate for ruggedline devices cable/conductor 2820000 ibs pwr/5 power supply cable, gray, welding-splash-resistant in standard applications, 5 x 1.5 mm2, sold by the meter 2731775 ibs pwr/5hd/f power supply cable, gray, welding-splash-resistant in standard applications, 5 x 1.5 mm2, highly stranded, sold by the meter 2733029 ibs rl connection-lk assembled cable jumper as a short connection between two interbus rugged line devices with fiber optic bus connectors and power supply, approximately 30 ? cm 2744319 psm-lwl-kdheavy-980/1000 polymer fiber cable, duplex 980/1000 m, medium-weight version for permanent indoor installation, by the meter, without connector
ibs rl 480 mlr r dio6/1-lk2mbd order no.: 2734497 http://eshop.phoenixcontact.de/phoenix/treeviewclick.do?uid=2734497 phoenix contact deutschland gmbh page 5 / 6 http://www.phoenixcontact.de feb 8, 2011 2744322 psm-lwl-rugged-980/1000 polymer fiber cable, duplex, 980 m/1000 m, heavy version for permanent indoor installation, sold by the meter without connectors 2744335 psm-lwl-rugged- flex-980/1000 polymer fiber cable, duplex 980/1000 m, heavy-weight, highly flexible version for flexible conduit applications, by the meter, without connector general 2740504 ibs rl mlr plset r-8a accessory set comprising: connectors and pg screw connections 2743705 ibs rl sys pro um user manual, german, for configuring and installing the rugged line product range, only available as a download. handheld operator panel 2837006 ibs hvo/m12 handheld operator panel, for interbus motor starters and interbus variable frequency drives in ip54 protection marking 2732729 ibs rl marker-set set of 50 small and 50 large metal marking labels plug/adapter 2725040 ibs rl 24 adap-lk/t interbus rugged line adapter for converting the fiber optic remote bus to a copper wire remote bus 2725037 ibs rl 24 adap-t/lk interbus rugged line adapter for converting the copper wire remote bus to a fiber optic remote bus 2731076 ibs rl plug-lk/pof connector for the fiber optic bus with polymer fiber cable and for the power supply with screw connection method
ibs rl 480 mlr r dio6/1-lk2mbd order no.: 2734497 http://eshop.phoenixcontact.de/phoenix/treeviewclick.do?uid=2734497 phoenix contact deutschland gmbh page 6 / 6 http://www.phoenixcontact.de feb 8, 2011 address phoenix contact deutschland gmbh flachsmarktstr. 8 32825 blomberg,germany phone +49 5235 3 12000 fax +49 5235 3 41200 http://www.phoenixcontact.de ? 2011 phoenix contact technical modifications reserved;