page 1 of 4 dc/dc converters ten 3win series, 3 watt ordercode input voltage range output voltage output current max. effciency max. 1500 vdc isolation 3000 vdc isolation ten 3-2410win - 3.3 vdc 750 ma 77 % ten 3-2411win ten 3-2411win-hi 5.0 vdc 600 ma 79 % ten 3-2412win ten 3-2412win-hi 12 vdc 250 ma 82 % ten 3-2413win ten 3-2413win-hi 15 vdc 200 ma 83 % ten 3-2415win ten 3-2415win-hi 9.0 C 36 vdc 24 vdc 125 ma 81 % ten 3-2421win ten 3-2421win-hi (nominal 24 vdc) 5.0 vdc 250 ma 80 % ten 3-2422win ten 3-2422win-hi 12 vdc 125 ma 82 % ten 3-2423win ten 3-2423win-hi 15 vdc 100 ma 82 % ten 3-4810win - 3.3 vdc 750 ma 77 % ten 3-4811win ten 3-4811win-hi 5 vdc 600 ma 80 % ten 3-4812win ten 3-4812win-hi 12 vdc 250 ma 83 % ten 3-4813win ten 3-4813win-hi 15 vdc 200 ma 84 % ten 3-4815win ten 3-4815win-hi 18 C 75 vdc 24 vdc 125 ma 82 % ten 3-4821win ten 3-4821win-hi (nominal 48 vdc) 5.0 vdc 250 ma 80 % ten 3-4822win ten 3-4822win-hi 12 vdc 125 ma 82 % ten 3-4823win ten 3-4823win-hi 15 vdc 100 ma 82 % models features ultra wide 4 : 1 input range input flter to meet en 55032, class a and fcc, level a without external components extended operating temperature range C40c to 85c models with 1500 vdc and 3000 vdc i/o isolation (functional insulation) dip-24 package high reliability, mtbf >1.0 mio. h 3-year product warranty ul 60950-1 the ten 3win series is a drop in replacement of the prevalent ten 3wi series. the up-to date design enables a cost reduction without any compromise to reliability and function. they come with an internal flter to meet en55032 class a without ex - ternal components. increased emc immunity and extended operating temperature range of -40c to 85c make these converters an ideal solution for cost critical but demanding applications. with the standard pinning it is a drop in replacement for common 3 watt converters in dip24 package. c b scheme iec 60950-1 http://www.tracopower.com
page 2 of 4 input specifications input current no load 24 vin models 30 ma typ. 48 vin models 20 ma typ. start-up voltage 24 vin models: 9.0 vdc (or lower) 48 vin models: 18 vdc (or lower) under voltage shut down (lock-out circuit) 24 vin models: 8.5 vdc max. 48 vin models: 17.5 vdc max. surge voltage (1 s max.) 24 vin models 50 v max. 48 vin models 100 v max. reflected ripple current 24 vin models 15 ma typ 48 vin models 10 ma typ. emc emissions en 55032 class a (without external components ) emc immunity en 55024 C esd (electrostatic discharge) en 61000-4-2, air 8 kv, contact 6 kv, perf. criteria a C radiated immunity en 61000-4-3, 10 v/m, perf. criteria a C fast transient / surge en 61000-4-4, 2 kv, perf. criteria a en 61000-4-5, 1 kv , perf. criteria a C external input capacitor 200 f, 100 v, esr 48 mohm C conducted immunity en 61000-4-6, 10 vrms, perf. criteria a short circuit input power 2000 mw max. internal power dissipation 1200 mw max. output specifications voltage set accuracy 2 % max. regulation C input variation (vin min. to vin max.) 1.0 % max. C load variation (0 C 100 %) single output models 1.0 % max. dual output models 2.0 % max. ( balanced load) minimum load not required ripple and noise (20 mhz bandwidth) 70 mvpk-pk max transient response time (25% load step change) 500 s max. transient response deviation (25% load step change) 5 % max. temperature coefficient 0.02 %/k current limitation >120 % of iout max., constant current short circuit protection continuous, automatic recovery http://www.tracopower.com dc/dc converters ten 3win series 3 watt
page 3 of 4 output specifications (continued) capacitive load 3.3 vout models: 680 f max. 5.0 vout models: 470 f max. 12 vout models: 330 f max. 15 vout models: 220 f max. 24 vout models: 100 f max. 5.0 vout models: 220 f max (each output) 12 vout models: 150 f max. (each output) 15 vout models: 100 f max. (each output) general specifications temperature ranges C operating (natural convection cooling 20 lfm) C40c to +85c C case temperature +100c max. C storage C55c to +125c derating 3.3 %/k above 70c humidity (non condensing) 95 % rel h max. reliability, calculated mtbf (mil-hdbk-217 f, at +25c, ground benign) >1 mio. h isolation voltage (60 s) C input/output 1500 vdc or 3000 vdc isolation capacitance C input/output 300 pf max. isolation resistance C input/output (500 vdc) >1000 m ohm switching frequency 90 khz min. (pulse frequency modulation pfm) safety standards cul/ul 60950-1, iec/en 60950-1 safety approvals C csa certificate of compliance can/csa-c22.2 no 60950-1-07, am 1:2011 ansi/ul std no 60950-1, 2nd ed, am 1:2011 C cb test certificate iec 60950-1:2005 2nd ed, am 1:2009 C certification documents www.tracopower.com/overview/ten3win environmental compliance C reach www.tracopower.com/info/reach-declaration.pdf C rohs rohs directive 2011/65/eu http://www.tracopower.com all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. dc/dc converters ten 3win series 3 watt
page 4 of 4 rev. march 28. 2018 outline dimensions (0.18) 4.5 22.86 (0.9) 20.3 2.54 31.8 (1.25 ) 10.2 (0.4 ) 15.24 (0.6) 91 1 22 23 23 16 14 bottom view 15.24 (0.6) 5.08 2.54 (0.8 ) (0.1) (0.18 ) (0.1) (0.2) 4.5 pin single dual 2 Cvin (gnd) Cvin (gnd) 3 Cvin (gnd) Cvin (gnd) 9 no pin common 11 ntc Cvout 14 +vout +vout 16 Cvout common 22 +vin (vcc) +vin (vcc) 23 +vin (vcc) +vin (vcc) pin-out dc/dc converters ten 3win series 3 watt physical specifications casing material non conductive fr4 potting material epoxy (ul 94v-0 rated) pin material copper alloy with gold plated subplate weight 12.8 g (0.45 oz) soldering temperature 260c / 10 s max. dimensions in [mm], () = inch pin diameter ? 0.5 0.05 (0.02 0.002) tolerances 0.5 (0.02) pin pich tolerances 0.25 ( 0.01) ntc = not to connect sp ec i?cati ons can be changed wi thout noti ce! make sure you are using the latest documentation, downloadable at www.tracopower. com www .tracopower. com
|