actdf8 13 7 - 865.0 - qcc8c saw filter : features ? l ow - loss bandpass filter . ? ceramic package for s urface m ounted t echnology ( smt ) ? lead- free production and rohs compliance package dimension s pin configuration 2 input / output 6 output / input others case ground sign data (unit: mm) sign data (unit: mm) a 1.00 d 1.50 b 1.27 e 3.80 c 0.60 f 3.80 mar king act f 8137 top view, laser marking " act ?: manufacturer?s mark ?f ?: saw filter ?8137 ?: part number matching configuration( single ended ---- single ended )
maximum ratings rating value unit source power p 15 dbm dc v oltage v dc 0 v operating t emperature r ange t a -40 ~ + 85 c storage t emperature r ange t stg -4 0 ~ + 8 5 c electrical characteristics reference temperature: t a = 2 5 terminating source impedance: z s = 50 ? terminating load impedance: z l = 5 0 ? characteristic min. typ. max. unit center frequency f c ? 865.0 ? mhz insertion attenuation il ? 10.3 13.0 db pass band ripple ( 863.8 mhz~ 866.2 mhz) pr 0.3 1.0 db gro up delay ripple ( 863.75 mhz~ 866.25 mhz) gr 60 200 ns 1 db bandwidth b 1db 3.0 3.3 mhz 3 db bandwidth b 3 db 3. 6 mhz 20 db bandwidth b 20db 5.9 6.5 mhz absolute attenuation 10 mhz ~ 8 40 mhz 3 0 42 db 900 mhz ~ 1000 mhz 3 0 40 rohs c ompli ant e lectrostatic sensitive device
typical frequency response
environmental c haracteristic s test item condition of test requirements 1 mechanical shoc k (a) drops: 3 times on concrete floor (b) height: 1.0m the saw filter shall remain within the electrical specifications after tests. 2 vibration resistance (a) frequency of vibration: 10~55hz (b) amplitude: 1.5mm (c) directions: x,y and z (d ) duration: 2 hours 3 moisture resistance (a) condition: 40 c, 90~95% r.h. (b) dur ation: 96 hours (c) wait 4 hours before measurement 4 climatic sequence (a) +70 for 16 hours (b) +55 for 24 hours , 90~95% r.h. (c) -25 for 2 hours (d) +40 for 24 hours , 90~95% r.h. ( e ) wait 4 hours before measurement 5 high temperature exposure (a) temperature: 70 c (b) duration: 250 hours (c) wait 4 hours before measurement 6 thermal impact (a) +70 c for 30 minutes ? -25 c for 30 minutes repeated 3 times (b) wait 4 hours before measurement remarks 8 - 1 static voltage static voltage between signal load & ground may cause deterioration & destruction of the saw filter. pl ease avoid static voltage. 8 - 2 ultrasonic cleaning ultrasonic vibration may cause deterioration & destruction of the saw filter. please avoid ultrasonic cleaning. 8 - 3 soldering only terminals of the saw filter may be soldered. please avoid soldering other parts of the saw filter. soldering profile
|