for more information, please visit the product page | for information on related products, view dc power jacks ????????? ?????????????????? cui .com 12/16/2015 1 of 5 series : swi6-e description: ac-dc power supply model output voltage output current output power ripple and noise 1 effciency level (vdc) max (a) max (w) max (mvp-p) swi6-3.3-e 3.3 1.5 4.95 100 vi swi6-5-e 5 1.5 7.5 100 vi swi6-5.9-e 5.9 1.2 7.08 100 vi swi6-7.5-e 7.5 1.0 7.5 100 vi swi6-9-e 9 0.67 6.03 100 vi swi6-12-e 12 0.6 7.2 120 vi swi6-15-e 15 0.5 7.5 150 vi notes: 1. at full load, nominal input, 20 mhz bandwidth oscilloscope, each output terminated with 0.1 f multilayer ceramic and 47 f low esr electrolytic capacitors. features ? up to 6 w continuous power ? doe level vi, cec, erp stage 2 ? no load power consumption < 0.1 w ? compact size ? universal input voltage range ? over voltage, over current, and short circuit protections ? ce safety approvals part number key base number reserved for custom confgurations swi6 - xx - e - xxx - cxx dc plug type: xxx = see output plug options on page 4 for more details st = stripped and tinned output voltage ac input type: europe date page
for more information, please visit the product page | for information on related products, view dc power jacks ?????????????????? cui .com date 12/16/2015 page 2 of 5 cui inc series : swi6-e description: ac-dc power supply input parameter conditions/description min typ max units voltage 90 264 vac frequency 47 63 hz current 0.19 a inrush current at 240 vac, full load, 25c, cold start 60 a leakage current 0.25 ma no load power consumption 0.1 w output parameter conditions/description min typ max units regulation 5 % hold-up time at full load 10 ms protections parameter conditions/description min typ max units over voltage protection output shut down over current protection output shut down, auto recovery short circuit protection output shut down, auto recovery safety & compliance parameter conditions/description min typ max units isolation voltage input to output at 10 ma for 1 minute 3,000 vac isolation resistance input to output at 500 vdc 10 m emi/emc ce mtbf as per telcordia sr-332, 25c 300,000 hours rohs 2011/65/eu environmental parameter conditions/description min typ max units operating temperature 0 40 c storage temperature -20 60 c operating humidity non-condensing 20 80 % storage humidity non-condensing 10 90 %
for more information, please visit the product page | for information on related products, view dc power jacks ?????????????????? cui .com date 12/16/2015 page 3 of 5 cui inc series : swi6-e description: ac-dc power supply dc cord ~ ~ ~ mechanical parameter conditions/description min typ max units dimensions 56 x 28 x 60 mm inlet plug europe weight 96 g mechanical drawing units: mm units: mm cord length 805 model no. cable cord length swi6-3.3-e ul2468 1,500 mm 30 swi6-5-e ul2468 1,500 mm 30 swi6-5.9-e ul2468 1,500 mm 30 swi6-7.5-e ul2468 1,500 mm 30 swi6-9-e ul2468 1,500 mm 30 swi6-12-e ul2468 1,500 mm 30 swi6-15-e ul2468 1,500 mm 30 table 1
for more information, please visit the product page | for information on related products, view dc power jacks ?????????????????? cui .com date 12/16/2015 page 4 of 5 cui inc series : swi6-e description: ac-dc power supply output plug options stripped and tinned a c b a b c c a b right angle plug str aight plug locking dc plug standard dc plug dc plug t ype 255 5 5 102 c a b c a b eiaj dc plug right angle plug str aight plug size a b c unit 5 5.5 2.1 9.5 mm 6 5.5 2.5 9.5 mm 7 3.5 1.35 9.5 mm 8 3.8 1.35 9.5 mm 9 3.8 1.05 9.5 mm x x x plug size: x = see above plug options plug angle: blank = straight r = right angle *contact cui for additional plug options plug polarity: p = center positive n = center negative size a b c unit 10 5.5 2.1 9.5 mm 11 5.5 2.5 9.5 mm size eiaj a b c unit 12 eiaj-1 2.35 0.7 9.5 mm 13 eiaj-2 4.0 1.7 9.5 mm 14 eiaj-3 4.75 1.7 9.5 mm
for more information, please visit the product page | for information on related products, view dc power jacks ????????? date 12/16/2015 page 5 of 5 cui inc series : swi6-e description: ac-dc power supply this device complies with part 15 of the fcc rules. operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. cui offers a one (1) year limited warranty. complete warranty information is listed on our website. cui reserves the right to make changes to the product at any time without notice. information provided by cui is believed to be accurate and reliable. however, no responsibility is assumed by cui for its use, nor for any infringements of patents or other rights of third parties which may result from its use. cui products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. a critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. headquarters 20050 sw 112th ave. tualatin, or 97062 800.275.4899 fax 503.612.2383 cui .com techsupport@cui.com rev. description date 1.0 initial release 08/07/2015 1.01 added models 08/12/2015 1.02 updated drawing 12/16/2015 the revision history provided is for informational purposes only and is believed to be accurate. revision history
|