www.pairuigroup.com page: 1 / 4 date: 06/13/2017 *subject to change without notice ac-dc converter dip-package amd-4 series features: input voltage range 85-305vac short circuit, over current, and over voltage protections board in-line type installation 100% burn-in test 3 year warranty rohs compliant model input voltage (vac) output voltage (vdc) output current (ma) efficiency typ. amd4-3 85-305 3.3 800 66% amd4-5 5 800 76% amd4-9 9 440 78% AMD4-12 12 330 79% amd4-15 15 260 80% amd4-24 24 160 81% note: other input and output models may available on request . electrical input parameters symbols test conditions / comment min. typ. max. units input voltage v in -- 85 -- 305 vac input frequency f line -- 47 -- 440 hz input current i in full load, v in =115vac -- 95 -- ma full load, v in =230vac -- 46 -- ma inrush current i inrush cold start, v in =115vac -- 16 -- a cold start, v in =230vac -- 30 -- a leakage current i leakage v in =265vac/50hz -- 0.1 -- ma external fuse recommend -- t1a/250vac(slow break)
www.pairuigroup.com page: 2 / 4 date: 06/13/2017 *subject to change without notice ac-dc converter dip-package amd-4 series electrical output parameters symbols test conditions / comment min. typ. max. units output voltage accuracy v out v in =100-240vac -- 0.3 -- % line regulation v out-line v in =100-240vac -- 1.0 -- % load regulation v out-load 20%-100% load -- 1.0 -- % ripple v ripple -- -- 100 -- mvp-p rise time -- full load, v in =115vac -- 200 -- ms full load, v in =230vac -- 100 -- ms hold time -- full load, v in =115vac -- 15 -- ms full load, v in =230vac -- 40 -- ms protection over current hiccup mode, it will auto-recovery after fault condition is removed over voltage hiccup mode, it will auto-recovery after fault condition is removed short circuit hiccup mode, it will auto-recovery after faul t condition is removed environment storage t storage humidity: 10% rh to 95% rh -40 -- +85 ambient operating temperature t a startup at rated voltage (please refer to derating curve) -40 -- +70 operating relative humidity h a non condensing 10 -- 85 % mtbf t mtbf mil-hdbk-217f(25 ) 200 -- -- khrs temperature coeffficient 0.03%/(0~50 ) vibration 10~500hz, 2g 10min./cycle, 80 min. each along x, y , z axes dimension(lxwxh) 35x25.4x17.8mm
www.pairuigroup.com page: 3 / 4 date: 06/13/2017 *subject to change without notice ac-dc converter dip-package amd-4 series electrical safety&emc safety standards design refer to ul1012, en60950, en60601, ul60950, en60601 isolation voltage i/p-o/p: 3.5kvac isolation resistance i/p-o/p:>100m ohms/500vdc/25 /70%rh emi/emc compliance to en55011, en55022(cispr22) class b, e n61000-4-2, 3, 4, 5 notes: 1.unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and input nominal voltage. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1f & 47f parallel capacitor . mechanical connection pin # single 1 nc 2 no pin 3 +vo 4 -vo 5 nc 6 ac 7 ac 8 no pin 9 no pin note: unit is mm(inch).
www.pairuigroup.com page: 4 / 4 date: 06/13/2017 *subject to change without notice ac-dc converter dip-package amd-4 series electrical curve derating curve static characteristic curve note block diagram
|