  specification model dc voltage rated current current range rated power peak current peak power note.6 output voltage adj. range line regulation load regulation setup, rise time hold up time (typ.) voltage range frequency range efficiency (typ.) input inrush current (typ.) leakage current over temperature safety standards harmonic current ems immunity working temp. note.5 dc ok realy contact ratings (max.) working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage ac current (typ.) 1500ms, 60ms/230vac 30 at full load 00ms, 60ms/115vac 20ms/230vac 20ms/115vac at full load 88 ~ 264vac 124 ~ 370vdc 47 ~ 63hz 89% 0.93/230vac 0.96/115vac at full load 1.4a/115vac 0.7a/230vac 29 ~ 33v 91% 56 ~ 65v 90% 35a/115vac 70a/230vac <1ma / 240vac normally w m ore than 3 and then shut down o/p voltage orks within 110 ~ 150% rated output power for seconds 1 4 ~ 17v >150% rated power, constant current limiting with auto-recovery within 3 seconds and more than 3 seconds shut down o/p voltage protection type : shut down o/p voltage, re-power on to recover 95 5 (tsw : detect on heatsink of power switch) protection type : shut down o/p voltage, recovers automatically after temperature goes down ul508 tuv en60950-1 approved , compliance to en55022 (cispr22) class b compliance to en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11, env50204, en55024, en61000-6-2 (en50082-2), en61204-3, heavy industry level, criteria a, semi f47 approved -25 ~ +70 (refer to output load derating curve) 60vdc/0.3a, 30vdc/1a, 30vac/0.5a resistive load 20 ~ 95% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 50 component:10 ~ 500hz, 2g 10min./1cycle, 60min. each along x, y, z axes; mounting: compliance to iec60068-2-6 289.9khrs min. mil-hdbk-217f (25 ) 40*125.2*113.5mm (w*h*d) 0.67kg; 20pcs/14.4kg/1.19cuft power factor (typ.) SDR-120-24 SDR-120-48 24v 48v 5a 2.5a 0 ~ 5a 0 ~ 2.5a 120w 120w 7.5a 3.75a 100mvp-p 120mvp-p 24 ~ 28v 48 ~ 55v 1.0% 1.0% 0.5% 0.5% 1.0% 1.0% SDR-120-12 12v 10a 0 ~ 10a 120w 15a 180w (3sec.) 100mvp-p 12 ~ 14v 1.0% 0.5% 1.0% features : SDR-120 series w ithstand voltage isolation resistance i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac o/p-dc ok:0.5kvac i/p-o/p, i/p-fg, o/p-fg:>100m ohms / 500vdc / 25 / 70% rh emi conduction & radiation environment safety & function emc (note 4) protection ripple & noise (max.) note.2 voltage tolerance note.3 1. all parameters not specially mentioned are measured at 230vac input, rated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regulation. 4. the power supply is considered a component which will be installed into a final equipment. the final equipment must be re-confirmed that it still meets emc directives. 5. installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. in case the adjacent device is a heat source, 15mm clearance is recommended. 6. 4 seconds max., please refer to peak loading curves. 7. derating may be needed under low input voltage. please check the derating curve for more details. 120w single output industrial din rail with pfc function high efficiency 91% and low power dissipation built-in active pfc function, pf>0.93 protections: short circuit / overload / over voltage / over temperature cooling by free air convection can be installed on din rail ts-35/7.5 or 15 ul 508 (industrial control equipment) approved en61000-6-2(en50082-2) industrial immunity level 100% full load burn-in test 3 years warranty 150% peak load capability built-in dc ok relay contact pq s e m i f 4 7 authorized distributor: total power international, inc. toll free: 877-646-0900(us) ph# (978) 453-7272 www.total-power.com
mechanical specification block diagram case no.992a unit:mm dc ok relay contact contact close when the output voltage reaches the adjusted output voltage. when the output voltage drop below 90% output voltage. 30v/1a resistive load contact open contact ratings (max.) detection pwm & pfc circuit o.l.p. u.v.p. emi filter rectifiers power switching filter & rectifiers +v dc ok -v i/p fg control o.v.p. & o.c.p. pfc circuit pfc control terminal pin no. assignment (tb1) terminal pin no. assignment (tb2) pin no. pin no. 1 1,2 2 3 4 3 assignment assignment fg ac/l ac/n dc output -v dc output+v admissible din-rail:ts35/7.5 or ts35/15 35 relay contact 1 2 3 125.2 113.5 40 tb1 SDR-120 series 120w single output industrial din rail with pfc function + 2 3 4 1 tb2 dc ok dc ok +v adj. authorized distributor: total power international, inc. toll free: 877-646-0900(us) ph# (978) 453-7272 www.total-power.com
180w ( 1 ) ( 2 ) 120w 100 sec. 3 sec. 180w 60w 15 sec. 3 sec. SDR-120 series 120w single output industrial din rail with pfc function input voltage (v) 60hz load (%) ambient temperature ( ) load (%) -25 0 continuous f or 3 sec. (typ.) 10 20 30 40 50 5 5 60 70 60 75 100 112.5 150 100 40 88 110 50 60 70 80 155 135 230 264 90 100 (vertical) output derating vs input voltage derating curve peak loading 12v others 12v others authorized distributor: total power international, inc. toll free: 877-646-0900(us) ph# (978) 453-7272 www.total-power.com


▲Up To Search▲   

 
Price & Availability of SDR-120

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X