  kaye valprobe ? series features ? operates on standard line voltage ? positions for two irtd standards fluid baths ? wide operating range covers most common application requirements ? ctr-40 stability to 0.005c or ctr-80 stability to 0.01c ? rapid cool down from ambient to C40c ? very low noise ? modest footprint with foor cart available for portability ? quick drain spout simplifes fuid change ? 120 minute cool-down from ambient to C80c ? mounted on casters for portability temperature calibration and reference dry wells ? htr and ltr series dry wells ? rapid response time with no oils or fuids ? stability of 0.02c to 0.05c for temperatures exceeding 300c ? lightweight yet rugged design for portability a mphenol advanced sensors
temperature calibration ctrC40 the ctrC40 is a portable temperature bath designed to meet the calibration and validation needs of the valprobe system. combined with the intelligent rtd (irtd) and valprobe software, the ctrC40 provides pre- study and post-study verifcations, as well as valprobe temperature sensor calibration. the advanced design combines excellent temperature stability and uniformity with a broad temperature range C40c to 150c to address most valprobe applications. the generous nine liter tank and specially designed valprobe immersion basket accommodate up to eight valprobe loggers, making calibration or verifcation a quick and easy process. the portable tabletop design easily fts onto a benchtop without consuming precious space. an optional foor cart, with locking casters, raises the unit to a convenient operating height and allows easy transport within your facility. intelligent rtd standard the irtd temperature standard (irtd 400) is a national industry of standards and technology (nist) traceable instrument calibrated from C195c to 420c with 0.025c accuracy over the entire range. this completely self-contained measurement system serves as the secondary standard providing traceability for valprobe calibration or verifcation. by interfacing with the valprobe software, the irtd 400 eliminates the potential for human error, ensuring accurate and traceable measurements. temperature calibration stable uniform heat sources kaye temperature references are designed for easy operation while delivering the highest level of temperature stability possible. these stable uniform heat sources combine rapid heat-up and cool- down with large sensor capacity to minimize overall calibration time. multiple calibration set points are programmed via the easy-to-use operator panel and displayed (set point or well temperature) to 0.01 degree accuracy. these references provide fully automated sensor calibration when used with kayes validator? 2000 and traceable irtd temperature standard. htr and ltr series dry wells the htr and ltr series dry wells are specifcally designed for calibrating sensors used for process validation. these are the most advanced reference units on the market, featuring fast heat-up and cool- down, large well capacity to accommodate 18 to 24 thermocouples, and they use no messy oils or fuids. the htr 400 is ideal for high-temperature applications such as autoclaves, dry heat ovens and sterilizer tunnels. the ltr models offer low-temperature performance for applications including freezers, cold rooms, incubators and autoclaves. the ltr model selection should be based on the applications low- temperature point. ctrC80 cryo temperature bath operating from C80c to 30c, the ctr delivers fast response, high stability, and automated sensor calibration for the most severe cold-temperature applications. a generous 3.7 liter tank is heated and cooled quickly and quietly by a two-stage refrigeration system (r507 and r508b). the ctrC80 is the ideal unit for calibrating temperature sensors used in freeze dryer, freezer, and cryo unit validation. valprobe immersion basket shown with irtd standard (not included). ltr series
ctr-40 temperature range -40c to 150c ambient operating range 15c to 25 set-point accuracy 0.5c temperature stability ? 0.005c at -40c ? 0.005c at -25c ? 0.005c at -150c temperature uniformity 0.01c typical cool-down time 25c to -40c, 110 minutes access opening 94 mm x 172 mm with positions for irtd and up to eight valprobe data loggers with immersion basket display led with 0.01c resolution computer interface rs232 off cart dimensions (h x w x d) 584 mm x 305 mm x 622 mm on cart dimensions (h x w x d) 819 mm x 305 mm x 622 mm volume 9 liters recommended bath fluids ? -40c to 130c, silicone oil type 200 (fve centistoke viscosity) ? -30c to 150c, silicone oil type 200 (10 centistoke viscosity) weight 32 kg power 115 vac 60 hz, 16 a or 230 vac 50 hz, 8 a 1700 w fault protection ? oven temperature limits (user can set) ? low voltage cutout ? automatic refrigeration turn off ? electrical fuse ctr-80 temperature range -80c to 100c ambient operating range 15c to 25 set-point accuracy 0.5c temperature stability 0.01c temperature uniformity 0.012c typical cool-down time 25c to -80c, 20 minutes access opening 86 mm x 114 mm with positions for (two) irtds and (three) 11 mm diameter x 203 mm deep calibration wells display led with 0.01c resolution computer interface rs232 dimensions (h x w x d) 762 mm x 305 mm x 610 mm weight 57 kg power 115 vac 60 hz, 16 a or 230 vac 50 hz, 8 a 1700 w fault protection ? oven temperature limits (user can set) ? low voltage cutout ? automatic refrigeration turn off ? electrical fuse valprobe series specifcations
irtd-400 temperature range -195c to 420c accuracy over range 0.025c accurate for one year, 0c to 60c ambient. includes calibration certifcate with traceability to nist. resolution 0.001c sensor element 200 platinum rtd sensor sheath material inconel 600 immersion depth (minimum) 101.6 mm calibration 0.01c kaye provides a re-certifcation service for calibrating the temperature standard. power probe ? unregulated dc, 10 to 25 v ? 850 mw at 15 v for frst probe ? 550 mw for each additional probe power supply 115 vac us-style adaptor or 230 vac vde-approved adaptor power supply is not required for use with the valprobe system. measurement rate one reading per second environmental ? ambient temperature range 0c to 60c ? humidity 0 to 95% non-condensing overall dimension length 603 mm grip 89 mm x 32 mm sensor sheath 457 mm x 6.35 mm htr 400 ltr C25/140 ltr C40/140 temperature range 25c above ambient to 400c C25c to 140c C40c to 140c ambient operating range 5c to 50c 5c to 50c 5c to 50c set-point accuracy 0.2c to 300c 0.2c 0.2c 0.3c to 400c temperature stability 0.02c to 300c 0.02c 0.02c 0.05c to 400c transfer calibration accuracy* 50c to 150c: 0.1c C25c to 80c: 0.1c C40c to C25c: 0.15c irtd standard to thermocouples 50c to 250c: 0.2c 80c to 130c: 0.15c C25c to 80c: 0.1c 250c to 350c: 0.3c 130c to 140c: 0.18c 80c to 130c: 0.15c 350c to 400c: 0.4c 130c to 140c: 0.18c typical heat-up time ambient to 90c: 5 minutes ambient to 80c: 6 minutes ambient to 80c: 6 minutes 90c to 125c: 3 minutes ambient to 140c: 14 minutes ambient to 140c: 14 minutes 350c: 25 minutes well confguration reference wells (2): 6.7 mm diameter x 127 mm deep reference wells (2): 6.7 mm diameter x 155 mm deep reference wells (2): 6.7 mm diameter x 155 mm deep calibration wells (8): 9 mm diameter x 155 mm) deep calibration wells (6): 9 mm diameter x 155 mm) deep calibration wells (6): 9 mm diameter x 155 mm) deep display led w/0.01c resolution led w/0.01c resolution led w/0.01c resolution computer interface rs232 rs232 rs232 dimensions 343 mm x 198 mm x 317.5 mm 343 mm x 198 mm x 317.5 mm 343 mm x 198 mm x 317.5 mm weight 8.2 kg 13.6 kg 13.6 kg power 115 vac 60 hz, 6 a or 230 vac 50 hz, 3 a 700 watts 115 vac 60 hz, 3 a or 230 vac 50 hz, 1.5 a 350 watts 115 vac 60 hz, 3 a or 230 vac 50 hz, 1.5 a 350 watts fault protection sensor burnout protection, over temperature thermal cutout, electrical fuse sensor burnout protection, over temperature thermal cutout, electrical fuse sensor burnout protection, over temperature thermal cutout, electrical fuse * transfer calibration accuracy is the difference between the thermocouple tip and the sensor of the irtd temperature standard. this accuracy includes well to well uniformity. aas-920-237b-03/2014 www.amphenol-sensors.com ? 2014 amphenol corporation. all rights reserved. specifcations are subject to change without notice. other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. valprobe series specifcations