JMX-94F magnet latching relay . high sensitivity & reliability . well anti-shock and anti-vibration.heavy contact load. JMX-94F a z 60 dc12v d 1 2 3 4 5 6 4 contact current 40:40a 60:60a 80:80a 5 coil rated voltage(v) dc: 9,12, 24 1 part number JMX-94F 2 contact arrangement a:1a b:1b 3 enclosure s: sealed type z: dust cover contact data contact arrangement 1a ? spstno ? , 1b ? spstnc ? contact material agcd o contact rating(resistive) 80a/250vac 60a/250v ac 40a/250vac max. switching power 20000va 15000va 10000v a max. switching voltage 300v ac max. switching current:80a contact resistance & voltage drop 50m |? (at 1a/24vdc) item 4.12 of iec 61810-7 ? 100mv (at rated load) item 4 .12 of iec 61810-7 electrical (rated load) mechanical (no load) 4 10 item 4.30 of iec 61810-7 6 10 item 4.31 of iec 61810-7 features 39 30 17.5 ordering information operation life coil parameter operate time ms dash numbers coil rated voltage vdc coil resistance |? 10% switching voltage vdc (50%-70% of rated voltage) pulse magnitude ms coil power consumption w reset time ms 009-1000 9 81 4.5~6.3 012-1000 12 144 6.0~8.4 024-1000 24 576 12.0~16.8 ?y 60 1 ? 20 ? 20 caution: 1.when latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously . coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay . if these conditions are not followed, it is possible for the relay to be in the magnetically neutral position . 2.switching voltage is for test purpose only and are no to be used as design criteria. 03001003499 operation condition insulation resistance 1000m |? min (at 500vdc) item 7 of iec 61810-5 dielectric strength between contacts 50hz 1500v item 6 of iec 61810-5 between contact and coil 50hz 4000v item 6 of iec 61810-5 creepage distance 8.4mm addenda b of iec61810-5 22 shock resistance functional 100m/s ;survival:1000 m/s 11ms iec68-2-27 t est ea vibration resistance 10~55hz double amplitude 1.5mm iec68-2-6 test fc terminals strength 5n iec68-2-21 t est ua1 solderability 235 ??? 2 ?? 3 ? 0.5s iec68-2-20 test t a method 1 ambient t emperature -25~70 ?? relative humidity 85% (at 40 ?? ) iec68-2-3t est ca mass 33g safety approvals safety approval cqc load 80a/220v ac dimensions wiring diagram mounting (bottom view) notes: 1).dimensions are in millimeters. 2).inch equivalents are given for general information only . 3).relays shall have plus(+) signs placed on the circuit diagram as shown. reference data JMX-94F 6 coil nil:singal coil; d: double coils 009-2000 9 4.5~6.3 012-2000 12 6.0~8.4 024-2000 24 12.0~16.8 ?y 60 2 ? 20 ? 20 2 40.5 27 2 2 288 mm /inch 19.08 2 5 . 4 3- 1.2 2 . 5 2 1 . 5 9 4- 1.2 5.08 2 . 5 2.8 (assistance mounting terminal) (assistance mounting terminal) 19.08 2 5 . 4 2.8 5.08 1 1 ( 1 0 ) ( 1 . 0 ) 0 . 6 20 0.6 2 5 . 6 3 0 39 28 5.5 2 . 5 9 12 8.5 3-1x0.4 3 . 5 5.08 (3-0.6x0.6) 1 7 . 5 1 1 0.047 0.751 0.200 0.110 0.200 0.110 0.751 0 . 8 5 0 1 . 0 0 0 0 . 0 9 8 0 . 0 9 8 1 . 0 0 0 0.047 0 . 6 8 9 m a x . 0.200 0 . 1 3 8 0.039 0.016 0.024 0.024 0 . 4 3 3 0.535max. 0.217 1.102 0 . 0 9 8 0 . 0 2 4 ( 0 . 0 3 9 ) 0.335 0.354 0.472 0.024 0.787 1 . 0 0 8 1 . 1 8 1 m a x . 0 . 4 3 3 ( 0 . 3 9 4 ) dimensions max. m a x . m a x . 169 170 - + + - + reset set ningbo huaguan electronics corporation l td .
|