model number designation p s 6 0 - 1 0 2 r - n m c n series name signal / power cable pullout method pressure port switch output interface rated pressure range pressure reference 102 ? 100 ~ 100 kpa 103 ? 100 ~ 1000 kpa 302 ? 100 ~ 300 kpa r compound pressure (negative pressure ~ positive pressure) cn connector pullout m m5 female screw n npn open collector p pnp open collector pressure switches with gauge ps60 part name material pressure port o ring sensor module board housing display board operation panel seet polyamide (resin of mxd6 series) brass (ni-plated) fluoro-rubber pbt (polybutyleneterephtalate) polyester internal structure applicable for negative through positive pressure with 10 mm thick slim housing suitable for use in clean rooms with easy-to-use push keys plug-in connector is provided for easy installation and maintenance space saving and mountable on din rails data protection by panel lock system low consumption by nondisplay mode features list of model numbers pressure port m 5 female screw npn open collector output pnp open collector output switch output 102r 302r 103r ? 100 ~ 100 kpa ? 100 ~ 300 kpa ? 100 ~ 1000 kpa ps60-102r-nmcn ps60-302r-nmcn ps60-103r-nmcn PS60-102R-PMCN ps60-302r-pmcn ps60-103r-pmcn t verify the above model numbers when placing orders. marking compatible with em c directive 1 2 3 4 6 5 1 2 3 4 5 6
ps60 pressure switches with gauge general specifications display power item model number 102r 302r 103r ps60 standard spe c ifi c ations pressure reference gauge non-corrosive gases ? 100 ~ 100 ? 100 ~ 300 ? 100 ~ 1000 200 600 1500 500 1000 2000 ? 10 ~ 50 0 ~ 50 35 ~ 85 no condensation ? 20 ~ 70 atmospheric pressure, humidity 65 %rh maximum approx. includihg cable 12 ~ 24 v 10 % including ripple percentage 30 100 (500 v dc) 3 %f.s. (0 ~ 50 c) 500 v ac, 60 s leakage current 1 ma maximum m5 female screw 3-digit led ? 100 ~ 100 kpa ? 100 ~ 300 kpa ? 0.10 ~ 1.00 mpa 1 %f.s. 1 count pressure medium rated pressure range kpa maximum pressure kpa break-down pressure kpa operating temp. range c compensated temp. range c operating humidity %rh storage temp. c net weight g supply voltage v dc consumption current ma max. insulation resistance m min. thermal error dielectric strength pressure port display element rated display range display accuracy ? ? reference temp. 25 c resolution unless otherwise specified, the specs are defined at an ambient temperature of 25 5 c and excitation voltage of 24 v dc. switch output 0 ~ 30 counts 30 v 100 ma maximum 1.2 (npn), 2.2 (pnp) ? 110 kpa (approx.) ~ 999 counts red led on 0.3 %f.s. maximum approx. 5, 25, 250 ps60 cable, din rail adaptor adjustable range switching capacity residual voltage v maximum display repeatability switch hysteresis response ms accessories open collector output (npn or pnp) adjustable by panel switch 2 no. of outputs output interface setting method
ps60 pressure switches with gauge c ir c uit diagrams pressure load s.output1 main circuit power b sensor common s.output2 load 2 !y indicator 1 led pressure indication sensor main circuit pressure power b s.output2 1 !y indicator 2 pressure indication led common s.output1 load load npn open collector pnp open collector swit c h output mode display range 0 v u q v u . p e f 0 q f s b u j p o pressure setting (operating point) 4 f u u j o h 4 f u u j o h - p x f s m j n j u
|