  Datasheet File OCR Text:
  1 g 6 d g6d pcb power relay slim, miniature relay, capable of relaying programmable controller and temperature controller outputs ? reduced board space, ideal for high-density mounting (45%. (6.5 mm (w) 17.5 mm (l) 12.5 mm (h)) ? small, yet switches 5 a at 250 vac/30 vdc. ? allows 300,000 operations wi th a 2a load at 250 vac or 30 vdc. rohs compliant application examples ? ideal for output applications of control equipments. characteristics note. the data given above are initial values. *1. measurement conditions: 5 vdc, 1 a, voltage drop method. *2. measurement conditions: the insulation resistance was measured with a 500 vdc megohmmeter at the same locations as the dielectric strength was measured. *3. this value was measured at a switching frequency of 120 operations/min. *4. the values indicated in parentheses ( ) are for the G6D-1A-ASI-AP. contact resistance *1 100 m max. operate time 10 ms max. release time 5 ms max. insulation resistance *2 1,000 m min. dielectric strength between coil and contacts 3,000 vac, 50/60 hz for 1min between contacts of the same polarity 750 vac, 50/60 hz for 1min impulse withstand voltage (between coil and contacts) 6 kv (1.2 x 50 s) vibration resistance destruction 10 to 55 to 10 hz, 0.75 mm single amplitude (1.5 mm double amplitude) malfunction 10 to 55 to 10 hz, 0.75 mm single amplitude (1.5 mm double amplitude) shock resistance destruction 1,000 m/s 2 malfunction 100 m/s 2 durability mechanical 20,000,000 operations min. (at 18,000 operations/hr) electrical 70,000 operations min. (5 a at 250 vac, resistive load) 70,000 operations min. (5 a at 30 vdc, resistive load) 300,000 operations min. (2 a at 250 vac, resistive load) 300,000 operations min. (2 a at 30 vdc, resistive load) (at 1,800 operations/hr) failure rate (p level) (reference value *3) 10 ma at 5 vdc (1 ma at 5 vdc) *4 ambient operating temperature -25 c to 70 c (with no icing or condensation) ambient operating humidity 5% to 85% weight approx. 3 g model number legend g6d- @@ - @ - @ ?? ? ? 12 3 4 1. number of poles 1: 1-pole 2. contact form a: spst-no (1a) 3. contact material asi: silver alloy (cadmium-free) 4. contact surface ap: au plated ordering information connecting socket ratings coil note 1. the rated current and coil resistance are measured at a coil temperature of 23c with a tolerance of 10%. note 2. the operating characteristics are measured at a coil temperature of 23c. note 3. the ?max. voltage? is the maximum voltage that can be applied to the relay coil. * the must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down. contacts enclosure rating contact form terminal shape model rated coil voltage minimun packing unit fully sealed spst-no (1a) pcb terminals g6d-1a-asi 5 vdc 25 pcs/tube 12 vdc 24 vdc G6D-1A-ASI-AP 12 vdc 24 vdc applicable relay model minimun packing unit g6d-1a-asi p6d-04p 25 pcs item rated voltage rated current (ma) coil resistance ( ) must operate voltage (v) must release voltage (v) max. voltage (v) power consumption (mw) % of rated voltage 5 vdc 40 125 70% max.* 10% min. 160% (at 23 c) approx. 200 12 vdc 16.7 720 24 vdc 8.3 2,880 item load resistive load contact type single contact material ag-alloy (cd free) (ag-alloy (cd free) and au plated)* rated load 5 a at 250 vac 5 a at 30 vdc rated carry current 5 a max. switching voltage 250 vac, 30 vdc max. switching current 5 a note. when ordering, add the rated coil voltage to the model number. example: g6d-1a-asi dc5 however, the notation of the coil voltage on t he product case as well as on the packing will be marked as @@ vdc. rated coil voltage * the content indicated in parentheses ( ) are for the G6D-1A-ASI-AP
2 g6d pcb power relay g 6 d engineering data dimensions maximum switching capacity durability ambient temperature vs. maximum coil voltage note. the maximum coil voltage is the maximum voltage that can be applied to the relay coil. ambient temperature vs. must operate and must release voltages g6d-1a-asi (-ap) shock malfunction g6d-1a-asi (-ap) sample: g6d-1a-asi 24 vdc number of relays: 5 pcs test conditions: impose a shock in the x, y, and z directions three times each with the relay energized to check the shock values that cause the relay to malfunction. switching current (a) switching voltage (v) 50 30 10 5 3 1 0.5 0.3 0.1 0 3 5 10 30 100 250 500 1,000 ac resistive load ac inductive load cos=0.4 dc resistive load dc inductive load durability (x10 4 operations) 250 vac/30 vdc resistive load 250 vac/30 vdc inductive load (cos=0.4/ l/r=7 ms) switching current (a) 1 2 3 4 5 6 7 8 9 10 500 300 100 50 30 10 5 3 0 maximum coil voltage (%) ambient temperature (c) 200 180 160 140 120 100 80 60 0 23 30 40 50 60 70 80 90 100 80 60 40 20 0 ambient temperature (c) must operate and must release voltage (ratio of rated voltage) (%) sample: g6d-1a-asi number of relays: 5 pcs -40 -20 0 20 40 60 80 must operating voltage must recovery voltage max. min. x max. min. x z' z z z' shock direction unit: m/s 2 y y y' y' x x x' x' de-energized energized 1,000 206 800 600 400 200 coil terminals 17.5 max. (17.3)* 6.5 max. (6.4)* 12.5 max. (12.4)* 2.54 2.54 (1.13) (0.71) 5.08 10.16 5.08 four, 1.1-dia. 1 57 13 0.5 3.5 0.3 5.08 7.62 2.54 0.5 0.8 5.08 * average value note: orientation marks are indicated as follows: g6d-1a-asi (-ap) terminal arrangement/ internal connections (bottom view) pcb mounting holes (bottom view) (no coil polarity) 19.7 max. (19.5)* 6.9 max. (6.7)* 2.54 2.54 (2.18) (0.86) 5.08 10.16 5.08 four, 1.1-dia. 10.8 0.3 3.6 7.62 2.54 0.65 5.08 * average value 6 0.1 socket p6d-04p pcb mounting holes (bottom view)
3 g6d pcb power relay g 6 d approved standards the rated values approved by each of the safety standards may be different from the performance characteristics individually de fined in this datasheet. ul recognized (file no. e41515) csa certified (file no. lr31928) en/tv certified (registration no. r50167084) precautions please refer to ?pcb relays common precautions? for correct use. model number of poles coil ratings contact ratings number of test operations g6d-1a-asi (-ap) 1 5 to 24 vdc 5 a, 250 vac 40c 6,000 5 a, 30 vdc 40c model number of poles coil ratings contact ratings number of test operations g6d-1a-asi (-ap) 1 5 to 24 vdc 5 a, 250 vac (resistive) 40c 6,000 5 a, 30 vdc (resistive) 40c model number of poles coil ratings contact ratings number of test operations g6d-1a-asi (-ap) 1 5, 12, 24 vdc 5 a, 250 vac (cos =1.0) 70c 70,000 5 a, 30 vdc (0 ms) 40c mounting ? more than two relays can be closely mounted right side up as shown in the following illustration. note. the space between each relay required for heat radiation may vary with operating conditions. contact your omron representative for details. ? use surge killer diode when switching a dc inductive load in micro load (about 10 to 100 ma). (carbon deposition may decrease the contact reliability.) socket mounting height mounting to a p6d ? the p6d is flux-resistive. do not wash the p6d with water. ? dismount the relay from the socket before soldering the socket to a pcb. correct use upper side upper side 6.5 mm current flow: 5 a max. 1.12 mm 7.62 mm in the upside-down direction current flow: 2 a max. 18.5 mm max.
4 g6d pcb power relay g 6 d application examples provided in this document are for reference only. in actual applications, confirm equipment functions and safety before using the product. consult your omron representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. make sure that the ratings and performance characteristics of the prod uct provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. omron corporation electronic and mechanical components company contact: www.omron.com/ecb cat. no. k127-e1-04 0316(0207)(o) note: do not use this document to operate the unit.


▲Up To Search▲   

 
Price & Availability of G6D-1A-ASI-AP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X