  Datasheet File OCR Text:
  wide universal 80-275vac input ul/en/iec60601-1 3rd edition approvals; 2mopp over voltage & over load protection 4000vac isolation class ii, 2 prong u.s. input effciency level v 2.56 x 2.17 x 1.40 model number output watts output voltage output amps total regulation (note 2) effciency amp1201-02 10 5vdc 2.0 5% 74% amp1201-03 12 6vdc 2.0 5% 76% amp1201-04 12 9vdc 1.33 5% 79% amp1201-05 12 12vdc 1.0 5% 79% amp1201-06 12 15vdc 0.8 5% 81% AMP1201-07 12 18vdc 0.66 3% 81% amp1201-08 12 24vdc 0.5 3% 81% rohs 2 2011 / 65 / eu 12w medical grade wallmount switching power adapters amp1201 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
* these are stress ratings. exposure of the devices to any of these conditions may adversely affect long term reliability. proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. all specifcations are typical at nominal input, full load, and 25c unless other - wise noted input specifications input voltage range 80-275 vac (100-240v nominal) frequency range 47-63 hz input current low line (100vac) 0.29a max. high line (240vac) 0.16a max. inrush current, typ (cold start) low line (100vac) 50a max. high line (230vac) 100a max. leakage current <100 ua protection class double insulated, class ii no load power consumption 0.3w output specifications voltage and current see selection chart output power range 0 to fl rating line regulation (fl) (note 1) 1%, max. over voltage protection 112-132% over load protection 110-150% auto-recovery transient response 110vin, fl 4ms temperature coeffcient 0.04%/c, typ ripple/noise (note 3) fl, 90vin 1% pk-pk max. short circuit protection continuous, self-recovering * start up / hold up time 100vin, fl 2s max. / 16ms min. general specifications input-out isolation 4000 vac effciency (fl, nom. vin) see selection chart safety ansi/aami es 60601-1:2005 (ul/cul/en/iec 3rd edition) physical specifications size 2.56 x 2.17 x 1.40 (65x55x35.6mm) construction wallmount style weight 5.64oz (160g) environmental specifications oper. temperature -10 to +50c (fl) * 50% load @ 70c (see derate curve next page) cooling free air convection flammability rating ul94v-1 storage temperature -40 to +85c (10-95% rh) * operating/storage humidity 0% to 95%, non-cond * emc compliance to en55011 (cispr11), en61000-3-2,-3 class b mtbf (mil-hdbk-217f, 25 c) 100,000 hrs min. effciency level v surge voltage 2kv min. esd air: iec61000-4-2, 8kv min. contact: iec61000-4-2, 6kv min. operating altitude 3000m max. vibration 10 ~ 500hz, 10min./1cycle, 60min. each along x, y, z axes, 5g min notes 1. line regulation defned as changing the input voltage 10% from nominal line at rated load. 2. total regulation is defned by as changing the load 40% from 60% rated load. 3. ripple & noise is measured by using a 20mhz bandwidth limited oscilloscope and terminating the output with a 0.47uf capacitor at rated load and nominal line. 12w medical grade wallmount switching power adapters amp1201 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
mechanical dimensions dc output connections coaxial plug: +vout -vout 5.5mm outer diameter 2.1mm inner diameter, female 11mm length, center + dimensions are in mm. derate curves 5214 medical mpu12aseries specificationnote: 1.outputcanprovideuptopeakloadwhenthepowersupplystartsup. continuousstayinginmorethanratedloadisnotallowed. 2.atfactory,in60%ratedloadcondition,eachoutputischeckedtobe withinvoltageaccuracy. 3.lineregulationisdefinedbychanging10%ofinputvoltagefrom nominallineatratedload. 4.loadregulationisdefinedbychanging40%ofmeasuredoutputload from60%ratedload. 5.ripple&noiseismeasuredbyusing20mhzbandwidthlimited oscilloscopeandterminatedeachoutputwitha0.47ufcapacitorat ratedloadandnominalline. 6.holduptimeismeasuredfromtheendofthelastchargingpulsetothe timewhichthemainoutputdropsdowntolowlimitofmainoutputat ratedloadandnominalline. 7.efficiencyismeasuredatratedload,andnominalline. 8.thespecificsfortestingtheenergyefficiencyofthisseriesareoutlined inaseparatedocumenttitled"testmethodforcalculatingtheenergy efficiencyofsingle-voltageinterchangeableac-dcandac-acpower supplies(august11,2004),"whichisavailableontheenergystar website. mechanicaldimensions: (unit:mm) outputcablerecommend: packing: 1.selectedoutputconnectorsandwire,pleaserefertoappendix. 2.mpu12a-102~103arerequiredtouseawg#18/6ftoutputcable. 3.mpu12a-104~108arerequiredtouseawg#20/6ftoutputcable. 4.theregulationandefficiencywillbechangedbymodifiedoutputcable . 1.netweight:130g approx. 2.optionaloutputconnectorsavailablecontactsalesfordetails. ratingchart: inputvoltage(vac) load(%) 80 50 60 70 80 90 100 110 100 120 140 160 180 200 220 240 260 280 (fig.1)inputvoltagederatingcurve modelno. voltagerange min (vdc) (vdc) (a) (a) (w) (w) (ms) (mvp-p) (%) (%) min max max outputcurrent (basedontheoutputvolt.) maximum outputpower ripple&noise totalregulation typ.efficiency noload consumption hold-uptime protectionmode mpu12a-102 5.0 5.99 1.66 2.00 10 50 74 0.3 12 12 12 12 12 12 12 olp olp olp olp olp olp olp 0.3 0.3 0.3 0.3 0.3 0.3 76 79 79 81 81 81 5 5 5 5 5 3 3 60 80 100 100 100 100 12 12 12 12 12 12 2.00 1.50 1.09 0.92 0.75 0.57 1.50 1.09 0.92 0.75 0.57 0.44 8.0 11.0 13.0 6.0 8.0 11.0 13.0 16.0 16.0 21.0 21.0 27.0 mpu12a-103 mpu12a-104 mpu12a-105 mpu12a-106 mpu12a-107 mpu12a-108 12wexternalmedicalgradepowersupply temperature(c) -10 0 10 0 10 20 30 40 50 60 70 80 90 100 110 20 30 40 50 60 70 80 (fig.2)temperaturederatingcurve medical mpu12aseries specificationnote: 1.outputcanprovideuptopeakloadwhenthepowersupplystartsup. continuousstayinginmorethanratedloadisnotallowed. 2.atfactory,in60%ratedloadcondition,eachoutputischeckedtobe withinvoltageaccuracy. 3.lineregulationisdefinedbychanging10%ofinputvoltagefrom nominallineatratedload. 4.loadregulationisdefinedbychanging40%ofmeasuredoutputload from60%ratedload. 5.ripple&noiseismeasuredbyusing20mhzbandwidthlimited oscilloscopeandterminatedeachoutputwitha0.47ufcapacitorat ratedloadandnominalline. 6.holduptimeismeasuredfromtheendofthelastchargingpulsetothe timewhichthemainoutputdropsdowntolowlimitofmainoutputat ratedloadandnominalline. 7.efficiencyismeasuredatratedload,andnominalline. 8.thespecificsfortestingtheenergyefficiencyofthisseriesareoutlined inaseparatedocumenttitled"testmethodforcalculatingtheenergy efficiencyofsingle-voltageinterchangeableac-dcandac-acpower supplies(august11,2004),"whichisavailableontheenergystar website. mechanicaldimensions: (unit:mm) outputcablerecommend: packing: 1.selectedoutputconnectorsandwire,pleaserefertoappendix. 2.mpu12a-102~103arerequiredtouseawg#18/6ftoutputcable. 3.mpu12a-104~108arerequiredtouseawg#20/6ftoutputcable. 4.theregulationandefficiencywillbechangedbymodifiedoutputcable . 1.netweight:130g approx. 2.optionaloutputconnectorsavailablecontactsalesfordetails. ratingchart: inputvoltage(vac) load(%) 80 50 60 70 80 90 100 110 100 120 140 160 180 200 220 240 260 280 (fig.1)inputvoltagederatingcurve modelno. voltagerange min (vdc) (vdc) (a) (a) (w) (w) (ms) (mvp-p) (%) (%) min max max outputcurrent (basedontheoutputvolt.) maximum outputpower ripple&noise totalregulation typ.efficiency noload consumption hold-uptime protectionmode mpu12a-102 5.0 5.99 1.66 2.00 10 50 74 0.3 12 12 12 12 12 12 12 olp olp olp olp olp olp olp 0.3 0.3 0.3 0.3 0.3 0.3 76 79 79 81 81 81 5 5 5 5 5 3 3 60 80 100 100 100 100 12 12 12 12 12 12 2.00 1.50 1.09 0.92 0.75 0.57 1.50 1.09 0.92 0.75 0.57 0.44 8.0 11.0 13.0 6.0 8.0 11.0 13.0 16.0 16.0 21.0 21.0 27.0 mpu12a-103 mpu12a-104 mpu12a-105 mpu12a-106 mpu12a-107 mpu12a-108 12wexternalmedicalgradepowersupply 2wuwr21waext sd d sd d sd ud ?d pd cd gd od ld wd sdd ssd ud ?d pd cd gd od ld eymiuta2wuwr21wanwr2mpiax1w 12w medical grade wallmount switching power adapters amp1201 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458


▲Up To Search▲   

 
Price & Availability of AMP1201-07

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X