Part Number Hot Search : 
LL103A07 1709F C1202 RH5RH66 GBPC3514 GBPC3514 PEB20550 8C424
Product Description
Full Text Search
 

To Download DILEM4-G Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  02/13/2015 012701 - hpl-ed2014 v9.0 en 1 / 12 contactor,?4p,?4kw/400v/ac3 part?no. ? DILEM4-G(24vdc) article?no.? 012701 catalog?no.? xtmf9a00td delivery?programme product range ? ? contactors application ? ? mini contactors for motors and resistive loads subrange ? ? dilem contactors utilization category ? ? ac-1: nicht induktive oder schwach induktive last, widerstands?fen ac-3: k?figl?ufermotoren: anlassen, ausschalten w?hrend des laufes ac-4: k?figl?ufermotoren: anlassen, gegenstrombremsen, reversieren, tippen connection technique ? ? screw terminals pole ? ? 4 pole rated?operational?current ? ? ? ac-3 ? ? ? 380 v 400 v i e a 9 ac-1 ? ? ? conventional free air thermal current, 3 pole, 50 - 60 hz ? ? ? open ? ? ? at 40 c i th =i e a 22 max.?rating?for?three-phase?motors,?50?-?60?hz ? ? ? ac-3 ? ? ? 220 v 230 v p kw 2.2 380 v 400 v p kw 4 660 v 690 v p kw 4 ac-4 ? ? ? 220 v 230 v p kw 1.5 380 v 400 v p kw 3 660 v 690 v p kw 3 contact sequence ? ? for use with ? ? dilem dile actuating voltage ? ? 24 v dc voltage ac/dc ? ? dc operation technical?data general standards ? ? iec/en 60947, vde 0660, csa, ul maximum operating frequency ? ? ? mechanical ? ops./h 9000 electrical (contactors without overload relay) ? ? page 05/070 climatic proofing ? ? damp heat, constant, to iec 60068-2-78 damp heat, cyclic, to iec 60068-2-30 ambient temperature ? c ? open ? c - 25 - 50 enclosed ? c - 25 - 40 mounting position ? ? as required, except vertical with terminals a1/a2 at the bottom
02/13/2015 012701 - hpl-ed2014 v9.0 en 2 / 12 mounting position ? ? mechanical shock resistance (iec/en 60068-2-27) ? ? ? half-sinusoidal shock, 10 ms ? ? ? basic unit without auxiliary contact module ? ? ? main contacts, make contacts ? g 10 basic unit with auxiliary contact module ? ? ? main contacts make contact ? g ? make ? g 10 auxiliary contacts make/break contacts ? g 20 / 20 degree of protection ? ? ip20 protection against direct contact when actuated from front (en 50274) ? ? finger and back-of-hand proof weight ? kg 0.17 terminal capacity of auxiliary and main contacts ? ? ? screw terminals ? ? ? solid ? mm 2 1 x (0.75 - 2.5) 2 x (0.75 - 2.5) flexible with ferrule ? mm 2 1 x (0.75 - 1.5) 2 x (0.75 - 1.5) solid or stranded ? awg 18 - 14 terminal screw ? ? m3.5 pozidriv screwdriver ? size 2 standard screwdriver ? mm 0.8 x 5.5 1 x 6 max. tightening torque ? nm 1.2 main?conducting?paths rated impulse withstand voltage u imp v ac 6000 overvoltage category/pollution degree ? ? iii/3 rated insulation voltage u i v ac 690 rated operational voltage u e v ac 690 safe isolation to en 61140 ? ? ? between coil and contacts ? v ac 300 between the contacts ? v ac 300 making capacity (cos ? to iec/en 60947) ? a 110 breaking capacity ? ? ? 220 v 230 v ? a 90 380 v 400 v ? a 90 500 v ? a 64 660 v 690 v ? a 42 short-circuit protection maximum fuse ? ? ? type 2 coordination gl/gg a 10 type 1 coordination gl/gg a 20 ac ac-1 ? ? ? rated operational current ? ? ? conventional free air thermal current, 3 pole, 50 - 60 hz ? ? ? open ? ? ? at 40 c i th =i e a 22 at 50 c i th =i e a 20
02/13/2015 012701 - hpl-ed2014 v9.0 en 3 / 12 at 55 c i th =i e a 19 enclosed i th a 16 notes ? ? at maximum permissible ambient air temperature. conventional free air thermal current, 1 pole ? ? ? notes ? ? at maximum permissible ambient air temperature. open i th a 60 enclosed i th a 50 ac-3 ? ? ? rated operational current ? ? ? open, 3-pole: 50 C?60 hz ? ? ? notes ? ? at maximum permissible ambient air temperature. 220 v 230 v i e a 9 240 v i e a 9 380 v 400 v i e a 9 415 v i e a 9 440v i e a 9 500 v i e a 6.4 660 v 690 v i e a 4.8 motor rating p kwh ? 220 v 230 v p kw 2.2 240v p kw 2.5 380 v 400 v p kw 4 415 v p kw 4.3 440 v p kw 4.6 500 v p kw 4 660 v 690 v p kw 4 ac-4 ? ? ? rated operational current ? ? ? open, 3-pole: 50 C?60 hz ? ? ? notes ? ? at maximum permissible ambient air temperature. 220 v 230 v i e a 6.6 240 v i e a 6.6 380 v 400 v i e a 6.6 415 v i e a 6.6 440 v i e a 6.6 500 v i e a 5 660 v 690 v i e a 3.4 motor rating p kwh ? 220 v 230 v p kw 1.5 240 v p kw 1.8 380 v 400 v p kw 3 415 v p kw 3.1 440 v p kw 3.3 500 v p kw 3 660 v 690 v p kw 3 dc rated operational current open ? ? ? dc - -1 ? ? ? 12 v i e a 20 24 v i e a 20 60 v i e a 20 110 v i e a 20 220 v i e a 20 dc - 3 ? ? ?
02/13/2015 012701 - hpl-ed2014 v9.0 en 4 / 12 12 v i e a 8 24 v i e a 8 60 v i e a 4 110 v i e a 3 220 v i e a 1 dc - 5 ? ? ? 12 v i e a 2.5 24 v i e a 2.5 60 v i e a 2.5 110 v i e a 2.5 220 v i e a 1 current heat losses (3- or 4-pole) ? ? ? to i th ? w 4.7 magnet?systems voltage tolerance ? ? ? dc operated ? ? ? pick-up voltage ? ? 0.85 ? 1.1 power consumption ? ? ? dc operation ? ? ? power consumption pick-up = sealing ? va/w 2.6 notes ? ? smoothed dc voltage or three-phase bridge rectifier duty factor ? % df 100 switching times at 100 % u c ? ? ? make contact ? ms ? closing delay ? ms ? closing delay min. ? ms 26 closing delay max. ? ms 35 opening delay ? ms ? opening delay min. ? ms 15 opening delay max. ? ms 25 closing delay with top mounting auxiliary contact ? ms max. 70 reversing contactors ? ? ? changeover time at 110 % u c ? ? ? changeover time min. ? ms 40 changeover time max. ? ms 50 arcing time at 690 v ac ? ms max. 12 auxiliary?contacts positive operating contacts to en 60947-5-1 appendix l, including auxiliary contact module ? ? yes rated impulse withstand voltage u imp v ac 6000 overvoltage category/pollution degree ? ? iii/3 rated insulation voltage u i v ac 690 rated operational voltage u e v ac 600 safe isolation to en 61140 ? ? ? between coil and auxiliary contacts ? v ac 300 between the auxiliary contacts ? v ac 300 rated operational current ? ? ? ac-15 ? ? ? 220 v 240 v i e a 6 380 v 415 v i e a 3 500 v i e a 1.5 dc l/r 15 ms ? ? ? contacts in series: ? a ? 1 24 v a 2.5
02/13/2015 012701 - hpl-ed2014 v9.0 en 5 / 12 2 60 v a 2.5 3 100 v a 1.5 3 220 v a 0.5 conv. thermal current i th a 10 control circuit reliability failure rate <10 -8 , < one failure at 100 million operations (at u e = 24 v dc, u min = 17 v, i min = 5.4 ma) component lifespan at u e = 240 v ? ? ? ac-15 operations x 10 6 0.2 dc current ? ? ? l/r = 50 ms: 2 contacts in series at i e = 0.5 a operations x 10 6 0.15 notes ? ? switch-on and switch-off conditions based on dc-13, time constant as specified short-circuit rating without welding ? ? ? maximum overcurrent protective device ? ? ? short-circuit protection only ? ? pkzm0-4 short-circuit protection maximum fuse ? ? ? 500 v ? a gg/gl 6 500 v ? a fast 10 current heat loss at a load of i th per contact ? w 0.3 data?for?design?verification?according?to?iec/en?61439 technical data for design verification ? ? ? rated operational current for specified heat dissipation i n a 22 heat dissipation per pole, current-dependent p vid w 0.68 equipment heat dissipation, current-dependent p vid w 0 static heat dissipation, non-current-dependent p vs w 2.6 heat dissipation capacity p diss w 0 iec/en 61439 design verification ? ? ? 10.2 strength of materials and parts ? ? ? 10.2.2 corrosion resistance ? ? meets the product standard's requirements. 10.2.3.1 verification of thermal stability of enclosures ? ? meets the product standard's requirements. 10.2.3.2 verification of resistance of insulating materials to normal heat ? ? meets the product standard's requirements. 10.2.3.3 verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects ? ? meets the product standard's requirements. 10.2.4 resistance to ultra-violet (uv) radiation ? ? meets the product standard's requirements. 10.2.5 lifting ? ? does not apply, since the entire switchgear needs to be evaluated. 10.2.6 mechanical impact ? ? does not apply, since the entire switchgear needs to be evaluated. 10.2.7 inscriptions ? ? meets the product standard's requirements. 10.3 degree of protection of assemblies ? ? does not apply, since the entire switchgear needs to be evaluated. 10.4 clearances and creepage distances ? ? meets the product standard's requirements. 10.5 protection against electric shock ? ? does not apply, since the entire switchgear needs to be evaluated. 10.6 incorporation of switching devices and components ? ? does not apply, since the entire switchgear needs to be evaluated. 10.7 internal electrical circuits and connections ? ? is the panel builder's responsibility. 10.8 connections for external conductors ? ? is the panel builder's responsibility. 10.9 insulation properties ? ? ? 10.9.2 power-frequency electric strength ? ? is the panel builder's responsibility. 10.9.3 impulse withstand voltage ? ? is the panel builder's responsibility. 10.9.4 testing of enclosures made of insulating material ? ? is the panel builder's responsibility. 10.10 temperature rise ? ? the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. 10.11 short-circuit rating ? ? is the panel builder's responsibility. the specifications for the switchgear must be observed. 10.12 electromagnetic compatibility ? ? is the panel builder's responsibility. the specifications for the switchgear must be observed. 10.13 mechanical function ? ? the device meets the requirements, provided the information in the instruction leaflet (il) is observed.
02/13/2015 012701 - hpl-ed2014 v9.0 en 6 / 12 technical?data?etim?5.0 low-voltage industrial components (eg000017) / magnet contactor, ac-switching (ec000066) electric engineering, automation, process control engineering / low-voltage switch technology / contactor (lv) / power contactor, ac switching (ecl@ss8-27-37-10-03 [aab718011]) rated control supply voltage us at ac 50hz ? v 0 - 0 rated control supply voltage us at ac 60hz ? v 0 - 0 rated control supply voltage us at dc ? v 24 - 24 voltage type for actuating ? ? dc rated operation current ie at ac-1, 400 v ? a 22 rated operation current ie at ac-3, 400 v ? a 9 rated operation power at ac-3, 400 v ? kw 4 rated operation current ie at ac-4, 400 v ? a 6.6 rated operation power ie at ac-4, 400 v ? kw 3 modular version ? ? no number of auxiliary contacts as normally open contact ? ? 0 number of auxiliary contacts as normally closed contact ? ? 0 connection type main current circuit ? ? screw connection number of normally closed contacts as main contact ? ? 0 number of main contacts as normally open contact ? ? 4 approvals product standards ? ? iec/en 60947-4-1; ul 508; csa-c22.2 no. 14-05; ce marking ul file no. ? ? e29096 ul category control no. ? ? nldx csa file no. ? ? 012528 csa class no. ? ? 3211-04 north america certification ? ? ul listed, csa certified specially designed for north america ? ? no
02/13/2015 012701 - hpl-ed2014 v9.0 en 7 / 12 characteristics 1: overload relay 2: suppressor 3: auxiliary contact modules enclosure totally insulated
02/13/2015 012701 - hpl-ed2014 v9.0 en 8 / 12 squirrel-cage motor operating characteristics starting:from rest stopping:after attaining full running speed electrical characteristics make: up to 6 x rated motor current break: up to 1 x rated motor current utilization category 100 % ac-3 typical applications compressors lifts mixers pumps escalators agitators fans conveyor belts centrifuges hinged flaps bucket-elevators air conditioning system general drives in manufacturing and processing machines
02/13/2015 012701 - hpl-ed2014 v9.0 en 9 / 12 extreme switching duty squirrel-cage motor operating characteristics inching, plugging, reversing electrical characteristics make: up to 6 x rated motor current break: up to 6 x rated motor current utilization category 100 % ac-4 typical applications printing presses wire-drawing machines centrifuges special drives for manufacturing and processing machines
02/13/2015 012701 - hpl-ed2014 v9.0 en 10 / 12 switching duty for non-motor loads, 3-pole, 4-pole operating characteristics non-inductive or slightly inductive loads electrical characteristics make: 1 x rated current break: 1 x rated current utilization category 100 % ac-1 typical applications electric heat
02/13/2015 012701 - hpl-ed2014 v9.0 en 11 / 12 short-time loading, 3-pole time interval between two loading cycles: 15 minutes dimensions
02/13/2015 eaton industries gmbh http://www.eaton.eu ? 12/2014 by eaton industries gmbh 012701 - hpl-ed2014 v9.0 en 12 / 12 2dile- + mvdile + dile 2dile--g + mvdile + dile additional?product?information?(links) il03407009z?(awa2100-0882)?mini?contactor?relay il03407009z (awa2100-0882) mini contactor relay ftp://ftp.moeller.net/documentation/awa_instructions/il03407009z2010_10.pdf ul/csa: approved rating data http://de.ecat.moeller.net/flip-cat/?edition=hplte&startpage=5.84


▲Up To Search▲   

 
Price & Availability of DILEM4-G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X