Part Number Hot Search : 
15B10 PP1FDS XXXGX XC2VPX20 F2804S MP4411 F2804S 2SC55
Product Description
Full Text Search
 

To Download HTU21D Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  HTU21D(f) sensor digital relative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 1 / 21 ? dfn type package ? relative humidity and temperature digital output , i2c interface ? fully calibrated ? lead free sensor , reflow solderable ? low power consumption ? fast response time description the HTU21D(f) is a new digital humidity sensor with temper ature output by meas. setting new standards in terms of size and intelligence, it is embedded in a reflow solderable dual flat no leads (dfn) package with a small 3 x 3 x 0.9 mm footprint. this sensor provides calibrated, linearized signals in digital, i2c format. HTU21D(f) digital humidity sensors are dedicated humidity and temperature plug and play transducers for oem applications where reliable and accurate measurements are needed. direct interface with a micro - controller is made possible with the module for humidity and temperature digital output s . these low power sensors are designed for high volume and cost sensitive applications with tight space constraints. every sensor is individually calibrated and tested. lot identification is printed on the sensor and an electronic identification code is stored on the chip C which can be read out by command. low battery can be detected and a checksum improves communicatio n reliability. the resolution of these digital humidity sensor s can be changed by command (8/12bit up to 12/14bit for rh/t). with meas improvements and miniaturization of this sensor, the performance - to - price ratio has been improved C and eventually, any device should benefit from its cutting edge energy saving operation mode. optional ptfe filter/membrane (f) protects ht u21 d digital humidity sensor s against dust and water immersion , as well as against contamination by particles. ptfe filter/membranes pr eserve a high response time. the white ptfe filter/membrane is directly stuck on the sensor housing. features applicatio ns ? full interchangeability with no calibration required in standard conditions ? automotive: defogging, hvac ? home appliance ? instantaneous desaturation after long periods in saturation phase ? medical ? printers ? compatible with automatized assembly processes, including pb free and reflow processes ? humidifier ? individual marking for compliance to stringent traceability requirements free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 2 / 21 nomenclature ht u2xy(f) htu 2xy modules htu2x y f modules perfo r mance specs ma x imum ratings ratings symbol value unit storage temperature t stg - 40 to 125 c supply voltage (peak) v cc 3.8v v dc humidity operating range rh 0 to 100 %rh temperature operating range t a - 40 to +12 5 c vdd to gnd - 0.3 to 3.6v v digital i/o pins (data/sck) to vdd - 0.3 to vdd+0.3 v input current on any pin - 10 to +10 ma peak conditions: less than 10% of the operating time exposure to absolute maximum rating conditions for extended periods may affect the sensor reliability. humidity accuracy : x = 0: +/ - 5%rh tolerance @55%rh = 1 : +/ - 3 %rh tolerance @55%rh output sensor: y = d for digital, i2c protocol = p for pwm interface, analog output = s for sdm interface convertible to analog output with embedded ptfe filter : htu2xyf free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 3 / 21 electrical and gener al items (@t = 2 5 c, @vdd = 3 v) characteristics symbol min typ max unit voltage supply vdd 1.5 3 .0 3 .6 v current consumption (1) sleep mode idd 0.0 2 0. 14 a m easuring 3 00 450 500 a power dissipation sleep mode 0. 06 0.5 w average 8bit (2) 2 . 7 w communication digital 2 - wire interface, i2c protocol heater vdd=3v 5.5mw/ t=+0.5 - 1.5c storage - 40c / 125c (1) conditions: v dd = 3v , sck= 400k hz at 25c (2 ) conditions: v dd = 3v , sck= 400khz , temp<60c , duty cycle <10% sensor performance relative humidity ( @t = 25 c, @vdd = 3 v ) characteristics symbol min typ max unit resolution 12 bit s 0.04 %rh 8 bit s 0.7 %rh humidity operating range rh 0 100 %rh relative humidity accuracy @25c (2 0%rh to 80 %rh) typ 2 %rh max see graph 1 %rh replacement fully interchangeable temperature coefficient (from 0c to 80c) t cc - 0.15 %rh/c humidity hysteresis 1 %rh measuring time (1) 12 bits 14 16 ms 11 bit s 7 8 ms 10 bit s 4 5 ms 8 bits 2 3 ms psr r 10 lsb recovery time after 150 hours of condensation t 10 s long term drift 0.5 %rh/yr response time (at 63% of signal) from 33 to 75%rh (2 ) rh 5 10 s (1) typical values are recommended for calculating energy consumption while maximum values shall be applied for calculating waiting times in communication. ( 2 ) at 1m/s air flow free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 4 / 21 graph 1 : relative humidi ty error budget cond itions at 25 c ? HTU21D(f) sensor s are specified for optimum accuracy measurements within 5 to 9 5 %rh. ? operation o ut of this range (< 5% or > 95 % rh, including condensation) is however possible. temperature co efficient compensati on equation using the following temperature coefficient compensation equation will guarantee relative humidity accuracy given p.3, from 0c to 80c: rhactualt ambient humidity in %rh, computed from HTU21D(f) sensor tactual humidity cell temperature in c, computed from HTU21D(f) sensor coefftemp temperature coefficient of the HTU21D(f) in %rh/c 0 1 2 3 4 5 6 7 8 9 10 0 10 20 30 40 50 60 70 80 90 100 delta relative humidity (%rh) relative humidity (%rh) maximal tolerance typical tolerance coefftemp t rh rh actual actualt dt compensate ? ? ? ? ) 25 ( free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 5 / 21 temperature characteristics symbol min typ max unit resolution 14 bit 0.01 c 12 bit 0.0 4 c temperature operating range t - 40 +12 5 c temperature a ccuracy @25c typ 0. 3 c max see graph 2 c replacement fully interchangeable measuring time (1) 14 bit 44 5 0 ms 13 bit 22 2 5 ms 12 bit 1 1 1 3 ms 11 bit 6 7 ms pssr 25 lsb long term drift 0.04 c /yr response time (at 63% of signal) from 15c to 45c (2 ) t 10 s (1) typical values are recommended for calculating energy consumption while maximum values shall be applied for calculating waiting times in communication. (2) at 1m/s air flow graph 2 : temperature error budget user guide HTU21D(f) application informat ion ? soldering instructions: lead free reflow solde ring recommended process for s o l de r i ng HTU21D(f) sensor standard r e fl ow s o l de r i ng o v ens m ay be used . 0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 - 40 - 20 0 20 40 60 80 100 120 delta temperature ( c) temperature ( c) maximal tolerance typical tolerance free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 6 / 21 HTU21D(f) sensor as a humidity sensitive component (as classified by ipc/jedec j - std - 020 or equivalent documented proce dure with peak temperature at 26 0 c during up to 30 seconds for pb - free assembly in ir/convection reflow ovens) must be handled in a manner consis tent with ipc/jedec j - std - 033 or an equivalent documented procedure. ipc - 1601 provides humidity control, handling and packing of pcbs. the HTU21D(f) s en s o r i s qua lifi ed t o w it h s t and one l ead free reflow soldering recommended process p r o fil e below according to jedec standard. mount parts within 24 hours after printing solder paste to avoid potential dry up . for manual soldering, contact time must be limited to 5 seconds at up to 350c. for the design of the HTU21D(f) sensor footprint , it is recommended to use dimensions according to figure below. recommended footprint for HTU21D(f) sensor s . values in mm. no specific conditioning of devices is necessary after soldering process, either manual or reflow soldering. o ptimized performance in case of metrological measurements can be reached with stabilization of devices (24 hours at 25c / 55%rh). similar process is a d vised after exposure of the devices to extreme relat ive humidity conditions. in no case, neither after manual nor reflow soldering, a board wash shall be applied. therefore , it is strongly recommended to use a no - clean solder paste. in case of applications with exposure of the sensor to corrosive gases or condensed water (i.e. environments with high relat ive humidity) the soldering pads shall be sealed (e.g. conformal coating) to prevent loose contacts or short cuts. free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 7 / 21 ? storage conditions and handling instructions i t is recommended to store HTU21D(f) sensor in its original packaging at following conditions: temperature shall be in the range of - 40c C 125c . ? temperature e ffect s relative humidity reading strongly depends on temperature. therefore, it is essential to keep humidity sensors at the same temperature as the air of which the relative humidity is to be measured. in case of testing or qualification the reference sensor a nd test sensor must show equal temperature to allow for comparing humidity readings. t he HTU21D(f) sensor should be mounted in a way that prevents heat transfer from electronic sensor or that keeps it as low as possible. advice can be ventilation, reduction of copper layers between the HTU21D(f) sensor and the rest of the pcb or milling a slit into the pcb around the sensor (1mm minimum width). example of HTU21D(f) sensor mounting w ith slits mills to minimize heat transfer ? m a t e r i a l s u sed f or s ea li ng / m oun t i ng for sealing and gluing (use sparingly ), u se high filled epoxy for electronic packaging and s ilicone . for any specific material please request to humidity.application@meas - spec.com . window must remain uncovered. free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 8 / 21 ? w i r ing c onside r a t ions and s ignal in t eg r i t y carrying the sck and data signal parallel and in close proximity (e.g. in wires) for more than 10 cm ma y result in cross talk and loss of communication. this may be resolved by routing vdd and/or gnd between the two data signals and/or using shielded cab les. furthermore, slowing down sck frequency will possibly improve signal integrity. power supp ly pins (vdd, gnd) must be bypassed with a 100nf capacitor if wires are used. capacitor should be placed as close as possible to the sensor . ? es d ( e l ec tr o s t a t i c d i scha r ge) esd immunity is qualified according to: ? jedec jesd22 - a11 4 method (human body model at 4 kv ) for pads & open window ? jedec jesd22 - a115 method (machine m odel 200v) ? esda esd - stm5.3.1 - 1999 and aec - q100 - 011 (charged device model, 750 v corner pins, 500v other pins) latch - up immunity is provided at a for ce current of 100ma with tamb= 25c according to jedec jesd78. for exposure beyond named limits the sensor need additional protection circuit. i nterface specificati on typical application circuit, including pull - up resistor rp and decoupling of vdd and gnd by a capacitor. ? power pins (vdd, gnd) the s upp l y v o lt age of HTU21D(f) sensor s m u s t be i n t he r ange of 1 .5 v dc - 3. 6 v dc . r e c o mm ended s upp l y v o lt age i s 3 v dc (regulated) . however the t ypical application circuit includes a pull - up resistor r on data wire and a 100nf decoupling capacitor between vdd and gnd, placed as close as possible to the sensor. n function comment 1 data data bit - stream 2 gnd ground 3 nc must be left unconnected 4 nc must be left unconnected 5 vdd supply voltage 6 sck selector for rh or temp pad ground or unconnected free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 9 / 21 ? s e r i al c l ock i nput ( sck ) sc k i s u s ed t o sy n c h r on i z e the c o mm un i c a ti on be t w een mi c r o c on t r o ll er and HTU21D(f) sensor . s i n c e t he i n t e r f a c e c on s i s t s of f u ll y s t a ti c l og i c t he r e i s no m i n im u m sc k f r equen cy . ? s e r i al da t a ( da t a ) the dat a pin is used to tra nsfer data in and out of the device. for sending a command to the HTU21D(f) sensor , data is valid on the rising edge of sck and must remain stable while sck is high. after the falling edge of sck, the data value may be changed. for safe communication data shall be valid t su and t hd before the rising and after the falling edge of sck, respectively. for reading data from the HTU21D(f) sensor , data is valid t vd after sck has gone low and remains valid until the next falling edge of sck. an external pull - up resistor (e.g. 10 k) on sck is required to pull the signal high only for open collector or open drain technology microcontrollers . in most of the cases, p ull - up resistor s are internally included in i/o circuits of microcontrollers . e lectrical characteri stics ? input/output dc characteristics (vdd= 3v , temperature= 25c unless otherwise noted) characteristics symbol min typ max unit low level output voltage vdd=3v - 4ma HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 10 / 21 ? timing diagram for digital input/output pads d ata directions are seen from the HTU21D(f) sensor . data line in bold is controlled by the sensor. data v alid read time is triggered by falling edge of anterior toggle. communication protocol with HTU21D(f) sensor ? start - up sensor the HTU21D(f) sensor r equire s a vol tage supply between 1.5 v and 3. 6v. after power up, the device needs at most 15 ms while sck is high for reaching idle state (sleep mode), i.e to be ready accepting commands from the mcu . no command should be sent before that time. soft reset is recommended at start, refer p.11 . ? s tart s equence (s) to initiate transmission, a start bit has to be issued. it consists of a lowering of the data line while sck is high followed by lowering sck. ? stop sequence (p) to stop transmission, a stop bit has to be issued. it consists of a heightening of the data line while sck is high preceded by a heightening of the sck . HTU21D(f) s e n sor list of commands and register adresse s for sample s ource code , please request to humidity.application@meas - spec.com . ? sending a command after sending the start condition, the subsequent i2c header consist o f a 7 - bit i2c device address 0x4 0 and a data di rection bit (0 for write access : 0x80 ). the HTU21D(f) sensor indicates the prop er reception of a byte by pulling the data pin low (ack bit) after the falling edge of the 8 th sck clock. after the i ssue of a measurement command (0xe3 f or temperature, 0xe5 for relative humidity), the m cu must wait for the measurement to complete. the basic commands are given in the table below: free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 11 / 21 ? hold/no hold master mode s there are two different operation modes to communicate with the HTU21D(f) sensor: hold master mode and no hold master mode. in the first case, the sck line is blocked (controlled by HTU21D(f) sensor) during measurement process while in the s econd case the sck line remain open for other communication while the sensor is processing the measurement. no hold master mod e allows for processing other i2c communication tasks on a bus while the HTU21D(f) sensor is measuring. a communication sequence of the two modes is available below. in the hold master mode, the HTU21D(f) pulls down the sck line while measuring to force the master into a wait state. by releasing the sck line, the HTU21D(f) sensor indicates tha t internal processing is completed and that transmission may be continued. in the no hold master mode, the mcu has to poll for the termination of the internal processing of the HTU21D(f) sensor. this is done by sending a start conditio n followed by the i2 c header ( 1 for read access: 0x81 ) as shown below. if the internal processing is finished, the HTU21D(f) sensor acknowledges the poll of the mcu and data can be read by the mcu. if the measurement processing is not finished, the HTU21D(f) sensor answers no ack bit and start condition must be issued once more. for both modes, since the maximum resolution of the measurement is 14 bit s , the two last least significant bits (lsbs, bits 43 and 44) are used for transmitting status information. bit 1 of the two lsbs indicates the measurement type (0: temperature, 1: humidity). bit 0 is currently not assigned. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 s 1 0 0 0 0 0 0 0 ack 1 1 1 0 0 1 0 1 ack i2c address + write command (see table p. 9 ) 19 20 21 22 23 24 25 26 27 s 1 0 0 0 0 0 0 1 ack measurement i2c address + read hold during measurement 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 0 1 1 1 1 1 0 0 ack 1 0 0 0 0 0 1 0 ack data (msb) data (lsb) status 46 47 48 49 50 51 52 53 54 1 0 0 1 0 1 1 1 nack p checksum hold master communication sequence command code comment trigger temperature measurement 0xe3 hold master trigger humidity measurement 0xe5 hold master trigger temperature measurement 0xf3 no hold master trigger humidity measurement 0xf5 no hold master write user register 0xe6 read user register 0xe7 soft reset 0xfe free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 12 / 21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 s 1 0 0 0 0 0 0 0 ack 1 1 1 1 0 1 0 1 ack i2c address + write command (see table p. 9 ) 19 20 21 22 23 24 25 26 27 m easurement s 1 0 0 0 0 0 0 1 nack measuring i2c address + read 19 20 21 22 23 24 25 26 27 m easurement s 1 0 0 0 0 0 0 1 ack continue measuring i2c address + read 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 0 1 1 1 1 1 0 0 ack 1 0 0 0 0 0 1 0 ack data (msb) data (lsb) status 46 47 48 49 50 51 52 53 54 1 0 0 1 0 1 1 1 nack p checksum no hold master communication sequence g rey blocks are controlled by HTU21D(f) sensor. for hold master sequence, bit 45 may be changed to nack followed by a stop condition to omit checksum transmission. for no hold master sequence, if measurement is not completed upon read command, sensor does not provide ack on bit 27 (more of these iterations are possible). if bit 45 is changed to nack followed by stop condition, checksum transmission is omitted. in those examples, the HTU21D(f) sensor output is s rh = 0111110010000000 (0x7c80 ) . for the calculation of physical values status bit s must be set to 0. refer to conversion of signal output s section p.14 . the maximum duration for measurement depends on the type of measurement and resolution chosen. maximum values shall be chosen for the communication planning of the mcu. refer to the table p. 3 and p. 4 regarding measuring time specifications. i2c communicat ion allows for repeated start conditions without closing prior sequence with stop condition. ? soft reset this command is used for rebooting the HTU21D(f) sensor switching the power off and on again. upon reception of this command, the HTU21D(f) sensor system reinitializes and starts operation according to the default settings with the exception of the heater bit in the user register. the soft reset takes less than 15ms. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 s 1 0 0 0 0 0 0 0 ack 1 1 1 1 1 1 1 0 ack p i2c address + write soft reset c ommand grey blocks are controlled by HTU21D(f) sensor. free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 13 / 21 ? user register the content of user register is described in the table below. reserved bits must not be changed and default values of respective reserved bits may change over time without prior notice. therefore, for any writing to user register, default values of reserved bits must be read first. t he end of b attery alert /status is activated when the battery power falls below 2.25v. the heater is intended to be used for functionality diagnosis: relative humidity drops upon rising temperature. the heater consumes about 5.5mw and provides a temperat ure increase of about 0.5 - 1.5c. otp reload i s a safety feature and lo a d the entire otp settings to the register, with the exception of the heater bit, before every measurement. this feature is disabled per default and it is not recommended for use. please use soft reset instead as it contains otp reload . bit #bits description/coding default 7,0 2 measurement resolution bit 7 bit 0 rh temp 0 0 12 bit s 14 bit s 0 1 8 bit s 12 bit s 1 0 10 bit s 13 bit s 1 1 11 bit s 11 bit s 00 6 1 status: end of battery (1) 0: vdd>2.25v 1: vdd<2.25v 0 3, 4, 5 3 reserved 0 2 1 enable on - chip heater 0 1 1 disable otp reload 1 (1) this status bit is updated after each measurement cut - off value for end of battery signal may vary by 0.1v. res erved bits must not be changed. otp reload active l oads default settings after each time a measurement command is issued. ? i2c communication reading and writing the user register example in this example, the resolution is set to 8 bit s / 12 bit s (for rh/temp) from default configuration. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 s 1 0 0 0 0 0 0 0 ack 1 1 1 0 0 1 1 1 ack i2c address + write read register command 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 s 1 0 0 0 0 0 0 1 ack 0 0 0 0 0 0 1 0 nack i2c address + read register content 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 s 1 0 0 0 0 0 0 0 ack 1 1 1 0 0 1 1 0 ack i2c address + write write register command 55 56 57 58 59 60 61 62 63 0 0 0 0 0 0 1 1 ack p register content to be written grey blocks are controlled by HTU21D(f) sensor. free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 14 / 21 ? c rc c hecksum HTU21D(f) sensor provides a crc - 8 checksum for error detection. the polynomial used is x 8 + x 5 + x 4 + 1 . basic considerations crc stands for cyclic redundancy check. it is one of the most effective error detection schemes and requ ires a mi nimal amount of re sources . the types of errors that are detectable w ith crc that is implemented in HTU21D(f) sensors are: ? any odd number of errors anywhere within the data transmission ? all double - bit errors a nywhere within the transmission ? any cluster of errors that can be contained within an 8 - bit window (1 - 8 bits incorrect) ? most larger clusters of errors a c rc is an error - detecting code commonly used in digital networks and storage devices to detect accidental changes to raw data. blocks of data entering these systems get a short check value attached, based on the remainder of a polynomial division of their contents; on retrieval the calculation is repeated, and corrective action can be taken against presumed data corruption if the check values do not match. crcs are so called because the check (data verification) value is a redundancy (it expands the message without adding information) and the algorithm is based on cyclic codes. crcs are popular because they are simple to implement in binary hardware, easy to analyze mathematically, and particularly good at detecting common errors caused by noise in transmission channels. because the check value has a fixed length, the function that generates it is occasionally used as a hash function. crc for HTU21D(f) s ensors u sing i2 c protocol when HTU21D(f) sensors are run by communicating with the standard i2c protocol, an 8 - bit crc can be used to detect transmission errors. the crc covers all read data transmitted by the sensor. crc properties for HTU21D(f) sensors communicating with i2 c protocol are listed in the table below . crc with i2c protocol gener ator poly nomial x 8 + x 5 + x 4 + 1 initialization 0x00 protected data read data final operation none crc calculation to compute an n - bit binary crc, line the bits representing the input in a row, and position the (n+1) - bit pattern representing the crc's divisor (called a "polynomial") underneath the left - hand end of the row. this is first padded with zeroes corresponding to the bit length n of the crc . if the input bit above the leftmost divisor bit is 0, do nothing. if the input bit above the leftmost divisor bit is 1, the divisor is xored into the input (in other words, the input bit above each 1 - bit in the divisor is toggled). the divisor is then s hifted one bit to the right, and the process is repeated until the divisor reaches the right - hand end of the input row. free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 15 / 21 since the left most divisor bit zeroed every input bit it touched, when this process ends the only bits in the input row that can be no nzero are the n bits at the right - hand end of the row. these n bits are the remainder of the division step, and will also be the value of the crc function. the validity of a received message can easily be verified by performing the above calculation again , this time with the check value added instead of zeroes. the remainder should equal zero if there are no detectable errors. crc examples the input message 11011100 (0xdc) will have as result 01111001 (0x79). the input message 01101000 00111010 (0x683a: 24. 7c) will have as result 01111100 (0x7c). the input me ssage 01001110 10000101 (0x4e85 : 32.3%rh) will have as result 01101011 (0x6b). c o nversion of signal o utputs default resolution is set to 12 - bit relative humidity and 14 - bit temperature reading s . measured data are transferred in two byt e packages, i.e. in frames of 8 - bit length where the most significant bit (msb) is transferred first (left aligned). each byte is followed by an acknowledge bit. the two status bits, the last bits of lsb, must be set to 0 befo re calculating physical values. to accommodate/adapt any process variation (nominal capacitance value of the humidity die), tolerances of the sensor above 100%rh and below 0%rh must be considered . as a consequence: ? 118%rh corresponds to 0xff which is the maximum rh digital output that can be sent out from the asic. rh output can reach 118%rh and above this value, there wil l have a clamp of the rh output to this value. ? - 6%rh corresponds to 0x00 which is the minimum r h digital output that can be sent out from the asic. rh output can reach - 6 %rh and below this value, there will have a clamp of the rh output to this value. ? relative humidity conversion with the relative humidity signal output s r h , the relative humidity i s obtained by the following formula (result in %rh), no matter which resolution is chosen: in the example giv en p.1 0 , the transferred 16 - bit relative humidity data is 0x7c80: 31872 . the relative humidity results to be 54.8 %rh . ? t emperature conversion the temperature t is calculated by inserting temperature signal output s temp into the following formula (result in c), no matter which resolution is chosen: 16 2 125 6 rh s rh ? ? ? ? 16 2 72 . 175 85 . 46 temp s temp ? ? ? ? free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 16 / 21 application: dew poi nt temperature measu rement the dew point is the temperature at which the water vapor in the air becomes saturated and condensation begins. the dew point is associated with relative humidity. a high relative humidity indicates that the dew point is closer to the current air temperature. relative humidity of 100% indicates that the dew point is equal to the current temperature (and the air is maximally saturated with water). when the dew point stays constant and temperature increases, re lative humidity will decrease. dew point temperature of the air is calculated using ambient relative humidity and temperature measurements from HTU21D(f) sensor with following formulas given below: partial pressure (pp tamb ) formula from ambient temperature: dew point temperature (t d ) formula from partial pressure (pp tamb ): pp tamb p artial pressure in mmhg at ambient temperature (t amb ) rh amb ambient humidity in %rh, computed from HTU21D(f) sensor t amb humidity cell temperature in c, computed from HTU21D(f) sensor t d calculated dew point in c a, b, c constants: a=8.1332; b=1762.39; c=235.66 ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? c a pp rh b t tamb amb d 100 log 10 ? ? ? ? ? ? ? ? ? ) ( 10 c tamb b a tamb pp free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 17 / 21 package outline ? HTU21D sensor dimensions ? HTU21Df sensor dimensions dimensions are given in mm, tolerances are 0.1mm. the die pad (thermal center pad) is internally connected to gnd. free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 18 / 21 ? packaging type HTU21D(f) sensors are provided in dfn packaging. dfn stands for dual flat no leads. the HTU21D(f) sensor chip is mounted to a lead frame made of cu and plated with ni/pd/au. chip and lead frame are over molded by green epoxy - based mold compound. please note that side walls of sensors are diced and hence lead frame at diced edge is not covered with res pective protective coating. the total weight of the sensor is 0.0 25g. ? traceability information a ll HTU21D(f) sensors ar e laser marked with an alphanumeric, five - digit code on the sensor as pictured below . the marking on the HTU21D(f) sensor consists of t wo lines with five digits each: ? the first line d enotes the sensor type: htu21 . ? the second line denotes several information as: o the first digit of the second line define s the output mode: ? d = digital and i 2c ? p = pwm ? s = sdm o the second digit defines the manufacturing year: 2 = 2012 , 3 = 201 3 , etc. o the last three digits represent an alphanumeric tracking code. that code can be decoded by meas only and allows for tracking on batch level through produc tion, calibration and testing and will be pro vided upon justified request. laser marking on HTU21D(f) sensor reels ar e also labe l ed, as displayed below and give additional traceability information. free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 19 / 21 with: xx: sensor type (21 for HTU21D(f) ) o: output mode (d = digital, p = pwm, s = sdm) (f): sensor with ptfe membrane (only for HTU21Df) nn: product revision n umber ttttttttt: meas traceability code yy: two last digits of the year ddd: day of the year qqqq: q uantity per real ( 400, 1500 or 5000 units) ? tape and reel packag ing HTU21D(f) sensors are shipped in tape & reel packaging, s ealed into antistatic esd bags. standard packaging sizes are 400, 1500 and 5000 un its per reel. e ach reel contains 440mm (55 pockets) header tape and 200mm (25 pockets) trailer tape. the drawing of the packaging tapes with sensor orientation is shown in the picture below . ? packaging reels for 400 and 1500 units: outside diameter of 7 (178mm) and a 1/2 (13mm) diameter arbor hole. for 5000 units: outside diameter of 13 (330mm) and a 1/2 (13mm) diameter arbor hole. user direction of unreeling free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 20 / 21 ordering information ** HTU21D C digital temperature and relative humidity modul e ** package: tape and reel m.p.q of 400 pieces , 1500 pieces or 500 0 pieces ? hpp828e031r4 - HTU21D in tape and reel of 400 pieces ? hpp828e031r1 - HTU21D in tape and reel of 1500 pieces ? hpp828e031r5 - HTU21D in tape and reel of 5000 pieces ** HTU21D f C digital temperature and relative humidity module with ptfe membrane * * package: tape and re el m.p.q of 400 pieces, 1500 pie ces or 5000 pieces ? hpp828e 1 31r4 - HTU21D f in tape and reel of 400 pieces ? hpp828e1 31r1 - ht u21d f in tape and reel of 1500 pieces ? hpp828e1 31r5 - HTU21D f in tape and reel of 5000 pieces ** HTU21D demokit C hpp828kit ** this is a usb device for meas model HTU21D digital relative humidity & temperature sensor demonstration. supporting up to 4 sensor acquisitions at the same time, it shows the consistency of different sensors and test sensor functions conveniently. for detailed information , please request to humidity.application@meas - spec.com . free datasheet http://www.datasheet-pdf.com/
HTU21D(f) sensor digital rel ative humidity sensor with temperature output hpc199_3 HTU21D(f) sensor datasheet www.meas - spec.com october 2013 21 / 21 customer service contact details measurement specialties, inc - meas france impasse jeanne benozzi cs 83 163 31027 toulouse cedex 3 france tel:+33 (0)5 820.822.02 fax:+33 (0)5.820.821.51 sales: humidity.sales@meas - spec.com meas w ebsite: http://www.meas - spec.com/humidity - sensors.aspx revision comments who date 0 document c reation d. le gall april 12 a general update d. le gall - zirilli february 1 3 2 HTU21Df product with embedded ptfe membrane reference added, storage conditions after soldering process updated (typing error) , esd performances updated, complementary information on rh output signal in c onversion of signal outputs paragraph, information on tape and reel packaging added, HTU21D demokit availability information added. d. le gall - zirilli ju ly 13 3 correction of i2c communication reading and writing, correction of soldering peak temperature m.robert october 2013 the information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. furthermore, this information does not convey to the purchaser of such devices any license under the patent rig hts to the manufacturer. measurement specialties, inc. reserv es the right to make changes without further notice to any product herein. measurement specialties, inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does measurement specialties, i nc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. typical parameters can and do vary i n different app lications. all operating parameters must be validated for each customer application by customers technical experts. measurem ent specialties, inc. does not convey any license under its patent rights nor the rights of others. free datasheet http://www.datasheet-pdf.com/


▲Up To Search▲   

 
Price & Availability of HTU21D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X