r o h s www.littelfuse.com 3 - 16 ? 2006 littelfuse, inc. ? telecom design guide
the do-214aa sidactor broadband optimized protection devices are intended for applications sensitive to load values. typically, high speed connections require a lower capacitance. c o values are 40% lower than standard devices. sidactor devices enable equipment to comply with various regulatory requirements including gr 1089, itu k.20, k.21 and k.45, iec 60950, ul 60950, and tia-968-a (formerly known as fcc part 68). * l in part number indicates roh s compliance. for non-rohs compliant device, delete l from part number. for surge ratings, see table below. general notes: ? all measurements are made at an ambient temperature of 25 c. i pp applies to -40 c through +85 c temperature range. ? i pp is a repetitive surge rating and is guaranteed for the life of the product. ? listed sidactor devices are bi-directional. all electrical parameters and surge ratings apply to forward and reverse polarities. ? v drm is measured at i drm. ? v s is measured at 100 v/s. ? special voltage (v s and v drm ) and holding current (i h ) requirements are available upon request. * current waveform in s ** voltage waveform in s electrical parameters part number * v dr m volts v s volts v t volts i dr m amps i s mamps i t amps i h mamps p0642 s _l 58 77 4 5 800 2.2 120 p0722 s _l 65 88 4 5 800 2.2 120 p0902 s _l 75 98 4 5 800 2.2 120 p1102 s _l 90 130 4 5 800 2.2 120 p1 3 02 s _l 120 160 4 5 800 2.2 120 p1 5 02 s _l 140 180 4 5 800 2.2 120 p1802 s _l 170 220 4 5 800 2.2 120 p2 3 02 s _l 190 260 4 5 800 2.2 120 p2602 s _l 220 300 4 5 800 2.2 120 p 3 002 s _l 280 360 4 5 800 2.2 120 p 35 02 s _l 320 400 4 5 800 2.2 120 p4202 s _l 190 250 8 5 800 2.2 120 p4802 s _l 440 600 4 5 800 2.2 120 p6002 s _l 275 350 8 5 800 2.2 120 s urge ratings in amps s eries i pp i t sm 5 0 / 60 hz amps di/dt amps/s 0.2x 3 10 * 0. 5 x700 ** 2x10 * 2x10 ** 8x20 * 1.2x 5 0 ** 10x160 * 10x160 ** 10x 5 60 * 10x 5 60 ** 5 x 3 20 * 9x720 ** 10x 3 60 * 10x 3 60 ** 10x1000 * 10x1000 ** 5 x 3 10 * 10x700 ** amps amps amps amps amps amps amps amps amps amps amps a 20 150 150 90 50 75 75 45 75 20 500 b 25 250 250 150 100 100 125 80 100 30 500
. /0
& telecom design guide ? ? 2006 littelfuse, inc. 3 - 17 www.littelfuse.com
* [a/b] in part number indicates that values are for both a and b surge ratings. note: off-state capacitance (c o ) is measured at 1 mhz with a 2 v bias. thermal considerations package s ymbol parameter value unit do-214aa t j operating junction temperature range -40 to +150 c t s storage temperature range -65 to +150 c r ja thermal resistance: junction to ambient 90 c/w capacitance values part number * pf m in m ax p0642 s [a/ b ]l 25 45 p0722 s [a/ b ]l 20 45 p0902 s [a/ b ]l 20 40 p1102 s [a/ b ]l 15 35 p1 3 02 s [a/ b ]l 15 35 p1 5 02 s [a/ b ]l 15 30 p1802 s [a/ b ]l 10 30 p2 3 02 s [a/ b ]l 10 25 p2602 s [a/ b ]l 10 25 p 3 002 s [a/ b ]l 10 25 p 35 02 s [a/ b ]l 10 20 p4202 s [a/ b ]l 10 20 p4802 s [a/ b ]l 520 p6002 s [a/ b ]l 5 20
|