home > product details lda100w model input voltage [v] output wattage [w] dc output [v/a] lda100w-3 ac 85 - 264 60 3v 20a lda100w-5 ac 85 - 264 100 5v 20a lda100w-9 ac 85 - 264 103.5 9v 11.5a lda100w-12 ac 85 - 264 102 12v 8.5a lda100w-15 ac 85 - 264 100.5 15v 6.7a lda100w-18 ac 85 - 264 100.8 18v 5.6a lda100w-24 ac 85 - 264 103.2 24v 4.3a lda100w- 24-h ac 85 - 264 103.2 (peak 156) 24v 4.3a (peak 6.5a) lda100w-30 ac 85 - 264 105 30v 3.5a LDA100W-48 ac 85 - 264 96 48v 2a features input range lda10 - 75f (ac85 - 264v) input range lda100 - 300w (ac85 - 132v/ac170 - 264v) autoranging input rugged pcb type built-in inrush current protection rohs compliant safety agency approvals complies with den-an ul1950, c-ul recogniz ed, tuv approved ul recognized, tuv approved, cs a certified (lda10f - lda150w) emi compliance fcc-b cispr22-b en55022-b vcci-b 2 year warranty(refer to instruction manual)
model lda100w-3 lda100w-5 lda100w-9 lda100w-12 lda100w-15 lda100w-18 lda100w-24 lda100w-24-h lda100w-30 LDA100W-48 max output wattage[w] 60 100 103.5 102 100.5 100.8 103.2 103.2 105 96 dc output * 3 3v 20a 5v 20a 9v 11.5a 12v 8.5a 15v 6.7a 18v 5.6a 24v 4.3a 24v 4.3 ( 6.5 ) a 30v 3.5a 48v 2.0a specifications model lda100w-3 lda100w-5 lda100w-9 lda100w-12 lda100w-15 lda100w-18 lda100w-24 lda100w-24-h lda100w-30 LDA100W-48 input voltage[v] ac 85 - 132 / 170 - 264 1 f current[a] acin 100v 2.4typ ( io=100% ) acin 200v 1.2typ ( io=100% ) frequency[hz] 47 - 440 efficiency[%] 75typ 79typ 80typ 81typ 82typ 82typ 83typ 83typ 83typ 82typ inrush current[a] acin 200v 30typ ( io=100% )( at cold start ) leakage current[ma] 0.75max ( 60hz , according to ul , csa , vde and den-an ) output voltage[v] 35912151824243048 current[a] * 1 20 20 11.5 8.5 6.7 5.6 4.3 4.3 ( 6.5 ) 3.5 2.0 line regulation[mv] 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max load regulation[mv] 40max 40max 100max 100max 120max 120max 150max 150max 180max 240max ripple[mvp-p] 0to+50 c 80max 80max 120max 120max 120max 120max 120max 120max 120max 150max -10-0 c 140max 140max 160max 160max 160max 160max 160max 160max 160max 200max ripple noise[mvp-p] 0to+50 c 120max 120max 150max 150max 150max 150max 150max 250max 150max 400max -10-0 c 160max 160max 180max 180max 180max 180max 180max 280max 180max 600max temperature regulation[mv] 60max 60max 120max 150max 180max 200max 290max 290max 360max 560max drift[mv] * 2 20max 20max 36max 48max 60max 72max 96max 96max 120max 192max start-up time[ms] 200max ( acin 100v , io=100% ) hold-up time[ms] 10typ ( acin 85v , io=100% ) 20typ ( acin 100v , io=100% ) output voltage adjustment range[v] 2.85 - 3.6 4.5 - 5.5 fixed ( "y"which can be adjusted the output is available as option :9 , 12 , 15 , 18 , 24 , 30 , 48v t 10% ) output voltage setting[v] xx xx 8.6 - 9.4 11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0 28.8 - 31.2 46.0 - 50.0 protection circuit and others overcurrent protection works over 105% of rating ( -h : peak ) and recovers automatically overvoltage protection 4.00 - 5.25v works at 115 - 140% of rating operating indication not provided remote sensing not provided remote on/off option ( refer to instruction manual ) isolation input-output ac3 , 000v 1minute , cutoff current = 10ma , dc500v 50m w min ( at room temperature ) input-fg ac2 , 000v 1minute , cutoff current = 10ma , dc500v 50m w min ( at room temperature ) output-fg ac500v 1minute , cutoff current = 100ma , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 20 - 90%rh ( non condensing )( refer to derating curve ) 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 20 - 90%rh ( non condensing ) 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , en60950-1 , en50178 , csa c22.2 no.234 complies with den-an and iec60950-1 conducted noise complies with fcc-b , cispr22-b , en55022-b , vcci-b others case size/weight 62 x 35 x 222mm ( w x h x d ) /360g max ( without chassis and cover ) cooling method convection * 1 peak load for 20sec. or less is acceptable if the total wattage is less than the rated wattage(24v:103.2w). * 2 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. * 3 ( ) : peak current * avoid prolonged use under over-load. * parallel operation with other model is not possible. * derating is required when operated with chassis and cover. lda100w rugged pcb type lda 100 w -5 - o ordering information 1 series name 2 output wattage 3 autoranging input 4 output voltage 5 optional c :with coating g :low leakage current r :with remote on/off s :with chassis sn :with chassis & cover y :with potentiometer r 12345 lda e-44 recommended noise filter nac-06-472 high voltage pulse noise type : nap series low leakage current type : nam series * the noise filter is recommended * to connect with several devices.
? overcurrent characteristics ( lda100w-5 ) ? static characteristics ( lda100w-5 ) ? rise time & fall time ( lda100w-5 ) ? derating curve convection forced air(0.5m 3 /min) ambient temparature c load factor % 100 80 60 40 20 0 -10 10 20 30 40 50 60 70 lda e-45 lda100w external view performance data
|