  specifications features data sheet fhp, fkp jan. 14, 2000 date fcx ?c series min. EDSX5-76A the fcx ? pressure transm itter accurately m easures gauge pressure and transmits proportional 4 to 20ma signal. the transmitter utilizes the unique micromachined capaci- tive silicon sensor with state-of-the-art microprocessor tech- nology to provide exceptional performance and functionality. 1. high accuracy 0.1% accuracy for all calibrated spans is the standard feature covering 13 to 10000kpa {0.13 to 100bar}. fuji? micro-capacitance silicon sensor assures this fea- ture for all elevated or suppressed calibration ranges without additional adjustment. 2. minimum inventory electronics unit, communication module, local indicatiors and electronics housing are interchangeable among all fcx ? models. 3. replaceable communication module fuji micro-electronics manufacturing technology offers replaceable communication module that makes fcx-a/c transmitter very unique design. in case of change in communication protocol all that needs to be done is just replace the module and the transmitter gets upgraded to the new version. 4. fuji/hart bilingual communication module the communication module is "bilingual" to speak both fuji proprietary protocol and hart. any hart compatible devices can communicate with fcx-a/c series trans- mitters. 5. application flexibility example features that render the fcx -c suitable for al- most any process applications includes: analog indicator at either the electronics side or ter- minal side full range of hazardous location approvals built-in rfi filter and lightning arrester ? -digits lcd meter functional specifications type: model fhp: 4 to 20ma model fkp: 4 to 20ma with digital signal service: liquid, gas, or vapour span, range and overrange limit: overrange limit [mpa] {bar} type f p 01 f p 02 f p 03 f p 04 lower range limit (vacuum limit) is; silicone fill sensor: see fig. 1 fluorinated fill sensor: 66kpa abs (500mmhg abs) at below 80 c conversion factors to different units; 1 mpa=10 3 kpa=10bar=10.19716kgf/cm 2 = 145.0377psi 1kpa=10mbar=101.9716mmh 2 o =4.01463inh 2 o output signal: model fhp: 4 to 20ma dc 2-wire model fkp: 4 to 20ma dc with digital signal super- imposed on the 4 to 20ma signal. span limit [kpa] {bar} fkp range limit [kpa] {bar} 13 {0.13} 50 {0.5} 300 {3} 1000 {10} fhp fhp/fkp max. ?00 to +130 {? to +1.3} ?00 to +500 {? to +5} ?00 to +3000 {? to +30} ?00 to +10000 {? to + 100} 8.125 {0.08125} 31.25 {0.3125} 187.5 {1.875} 625 {6.25} 130 {1.3} 500 {5} 3000 {30} 10000 {100} 1 {10} 1.5 {15} 9 {90} 15 {150} pressure transmitter 1 2
fhp, fkp 2 power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with optional arrester. load limitations: see figure below loop-check output: model fhp: transmitter can output constant signal of 4ma, 12ma, or 20ma if mode switch is set to the loop check mode. model fkp: transmitter can be configured to provide constant signal 3.8ma through 21.6ma by hhc. temperature limit: ambient: ?0 to +85 c (?0 to +80 c for lcd indicator) (?0 to +60 c for arrester option) (?0 to +60 c for fluorinated oil fill transmitter) for explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified by each standard. process: ?0 to +100 c for silicone fill sensor ?0 to +80 c for fluorinated oil fill sen- sor storage: ?0 to +90 c humidity limit: 0 to 100% rh communication: (model fkp only) with hhc (model fxw, consult data sheet no. eds8-47), following informa- tion can be remotely displayed or recon- figured. hhc's version must be higher than 5.0, to communicate with the type "f p 01." note: for communication with fxw, min. of 250 ? required. hazardous locations: baseefa ex ds iic t5, t6 eex ia iic t4, t5 ex n ii t5 factory class i ii iii class i ii iii class i ii iii mutual div. 1 div. 1 div. 2 groups b thru. g groups a thru. f groups a thru. g csa class i ii iii class i ii iii class i ii iii div. 1 div. 1 div. 2 groups c thru. g groups a thru. g groups a thru. g saa ex d ii c t5, t6 ex ia ii c t5, t6 ex n ii c t5, t6 ip 66/67 ip 66/67 ip 66/67 type n nonincendive authorities flameproof intrinsic safety zero/span adjustment : model fhp: zero is adjustable from an external adjust- able screw. the adjustable screw can also function to adjust span when mode switch (lo- cated on the electronics unit) is in the span mode. inhibit mode to disable the ad- justable screw is also available. model fkp: zero and span are adjustable either from the hhc. zero is also adjustable exter- nally from the adjustable screw. damping: adjustable electrical damping. model fhp: the time constant is adjustable to 0, 0.3, 1.2, 4.8, or 19.2 seconds. model fkp: the time constant is adjustable between 0 to 38.4 seconds. (9 steps) zero elevation/suppression: model fhp: zero may be elevated or suppressed within the specified range limit of each sensor model. model fkp: selectable from hhc normal/reverse action: selectable by moving a jumper pin located on the electronics unit. indication: analog indicator or 4 -digit lcd meter, as specified. burnout direction: output hold output 21.6ma selectable output 3.8ma model fhp: unless otherwise specified, the burnout is in hold position. model fkp: selectable from hhc tag no. model no. serial no. engineering unit range limit measuring range damping output mode burnout direction adjustment output adjust data self diagnoses printer external switch lock transmitter display(*) items display set vv vv v vv v vv vv vv vv vv ? v v vv vv note: (*) hhc's version must be higher than 5.0 (or fxw 1? 2), to use this func- tion. 2000 [ ? ] 1500 1000 load resistance 500 250 1533 ? 600 ? operating area 24v 45v 10 16.1 50 [ v ] 10.5v power voltage } 1 2
3 physical specifications electrical connections: g1/2, 1/2-14 npt, pg13.5, or m20 x 1.5 conduit, as specified. process connections: 1/2-14npt, rc1/2, rc1/4 or 1/4-18npt, as specified. process-wetted parts material: performance specifications accuracy rating: (including linearity, hysteresis, and re- peatability) for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url (model fkp only): (0.05 + 0.05 ) % of span stability: 0.2% of upper range limit (url) for 24 months (in case of 6th digit code "2", "3", "4") temperature effect: effects per 28 c change between the lim- its of ?40 c and +85 c at (1 to 1/2.5) x url zero shift : 0.25%/28 c at (1 to 1/2.5) x url (0.25 )%/28 c for spans below 1/2.5 of url total effect: 0.5%/28 c at (1 to 1/2.5) x url (0.25+0.25 )%/28 c for spans below 1/2.5 of url overrange effect: zero shift, 0.3% of url for any overrange to maximum limit supply voltage effect: less than 0.05% fo calibrated span per 10v rfi effect: less than 0.2% of url for the frequen- cies of 20 to 1000mhz and field strength 30 v/m when electronics covers on. (classification: 2-abc: 0.2% span per sama pmc 33.1) step response: time constant: 0.2s dead time: about 0.3s (without electrical damping) mounting position effect: zero shift, less than 0.1kpa {1mbar} for a 10 tilt in any plane. no effect on span. this error can be cor- rected by adjusting zero. (double the effect for fluorinated fill sen- sors) dielectric strength: 500v ac, 50/60hz 1 min., between circuit and earth insulation resistance: more than 100m ? at 500v dc turn-on time: 4 sec. internal resistance for external field indicator: 12 ? or less v 316 stainless steel material code (7th digit in code symbols) process cover diaphragm wetted sensor body 316 stainless steel 316l stainless steel non-wetted parts material: electronics housing: low copper die-cast aluminum alloy (standard), finished with epoxy/polyurethane double coat- ing, as specified. fill fluid: silicone oil (standard) or fluori- nated oil (daifloil) mounting bracket: 304 stainless steel environmental protection: iec ip67 and nema 4x mounting: on 60.5mm (jis 50a or 2b) pipe using mounting bracket, direct wall mounting, or direct process mounting. mass{weight}: transmitter approximately 1.9kg without options. add; 0.5kg for mounting bracket 0.8kg for indicator option 0.1 x url span 0.4 x url span 0.4 x url span
fhp, fkp 4 optional features indicator: a plug-in turnable analog indicator (1.5% accuracy) can be housed in the electronics compartment or in the terminal box of the housing. an optional 4 digits lcd meter is also available. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity : 4kv (1.2 x 50 s) oxygen service: special cleaning procedures are followed throughout the process to maintain all pro- cess wetted parts oil-free. the fill fluid is fluorinated oil. degreasing: process-wetted parts are cleaned, but the fill fluid is standard silicone oil. not for use for oxygen or chlorine measurement. nace specification: metallic materials for all pressure bound- ary parts comply with nace mr-01-75. hand-held communicator: (model fxw, refer to data sheet no. eds8-47) communication module: (standard for model fkp) when using this module for model fhp, remote setting function becomes avail- able. remark: when the communication module is con- nected, the operation mode of external zero/span adjustable screw is changed to zero adjustment only. fig. 1 relation between process temperature and operating pressure customer tag: a stainless steel tag with customer tag data is wired to the transmitter. ?0 60 100 none-operating area 2.7 (20) 4 (30) 20 operating pressure process temperature[ c ] (150) 101 (760) [kpa abs] (mmhg abs) silicone oil (code:y,g,n) operating area accessories 1 2 the product conforms to the requirements of the electromagnetic compatibility directive 89/336/eec as detailed within the technical construction file number tn510412. the applicable standards used to demonstrate compliance are :- emi (emission) en50081-1 : 1992 "lvd - the transmitter is not covered by the requirements of the lvd standard." ems (immunity) en50082-1 : 1992 test item frequency range basic standard applicable electro- magnetic radiation disturbance 30-1000mhz en55022 class b test item no. test specification basic standard performance criteria 1 2 3 b a b electrostatic discharge fast transients common mode 0.5kv, 5/50 (tr/th) ns 5khz rep. radio-frequency electromagnetic field. 8kv (air) 27-500mhz 3v/m (unmodulated) iec 801-2:1984 iec 801-3:1984 iec 801-4:1988
5 description 01 0 f p 12345678 910111213 1415 a b d j e f h k l p q s a d e m n h j k p r t q y g a n y b a c y a b c type 4 to 20 ma, output type. 4 to 20 ma with digital signal, output type. connections process conn. conduit conn. g1/2 1/2-14npt 1/2-14npt pg 13.5 m20 x 1.5 span limit fhp/fkp kpa {bar} 13/8.125? 130 {0.13/0.08125?1.3} 50/31.25? 500 {0.5/0.3125 ? 5} 300/187.5?3000 {3/1.875 ? 30} 1000/625 ?0000 {10/6.25 ?00} material process cover diaphragm wetted cell body 316 stainless steel 316l stainless steel 316 stainless steel indicator and arrester indicator arrester none none analog, 0 to 100% linear scale none analog, custom scale none analog, double scale none none yes analog, 0 to 100% linear scale yes analog, custom scale yes analog, double scale yes digital, 0 to 100% none digital, custom scale none (model fkp only) digital, 0 to 100% yes digital, custom scale yes (model fkp only) approvals for hazardous locations none (for ordinary locations) fm, flameproof (or explosionproof) (available for 4th digit code" t") csa, flameproof (or explosionproof) (available for 4th digit code "t") baseefa, flameproof (conduit seal) baseefa, flameproof (cable gland seal) (conduit connection g 1/2 only) fm, intrinsic safety and nonincendive csa, intrinsic safety and nonincendive cenelec, intrinsic safety cenelec, intrinsic safety and baseefa, type n saa flameproof (conduit seal) (available for 4th digit code "s, t, w") saa intrinsic safety (available for 4th digit code "s, t, w") saa type ?n (non-speaking) (available for 4th digit code "s, t, w") mounting bracket none yes (stainless steel) optional specification stainless tag none yes special application and fill fluid treatment filled liquid none (standard) silicon oil degreasing silicon oil oxygen service fluorinated oil nace specification silicon oil process adaptor none (1/2 -14npt) rc1/4 rc1/2 1/4-18npt h k s t v w 1 2 3 4 v code symbols
outline diagram (unit:mm) fhp, fkp h k f p v1 s t v w adapter connection l rc1/2 npt1/4 rc1/4 gh j k 44 31 27 16 14 25 22 8 table 2 4th of code symbols s t v w d g1/2 1/2-14npt pg13.5 m20 1.5 conduit conn. e 17 16 8 16 f 8 5 4.5 5 earth terminal m4 no. 8-32unc m4 m4 table 1 note *: cable gland is supplied in case of flameproof packing type. fastener (flameproof ex. only) + table 1 note *: cable gland is supplied in case of flameproof packing type. ck+ ck + 108 80 "b" conduit conn. zero/span adj. screw 170 in case of 4th digit code "s, v, w" up down "c" conduit conn. 2 holes 9 dia. cable gland (option) see note 110 50 88 196 27 70 85 earth terminal (both side) see table 1 u-bolt m8 mtg. pipe jis 50a (2b) with field ind. (option) 71 51 (27) 80 g 214 hexagon socket head cap screw m4 h j 35 details of "a" (press conn.) "a" press. conn. "d" adapter (option) see table 1 see table 1 18 16 1/2-14npt details of "b" (conduit conn.) see table 1 15 f e d details of "c" 13 17 g1/2 details of "d" 6 k l 75 20 connection diagrams information in this catalog is subject to change without notice. printed in japan head office 11-2 osaki 1-chome, shinagawa-ku, tokyo, 141-0032 japan phone: 81-3-5435-7111 http://www. fujielectric.co.jp/eng/sg/keisoku/welcome.htm sales div. international sales dept. no.1, fuji-machi, hino-city, tokyo 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187, 6189


▲Up To Search▲   

 
Price & Availability of EDSX5-76A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X