  1 g4a special-purpose pcb relay miniature single-pole relay with 80-a surge current and 20-a switching current  ideal for motor switching.  miniature, relay with high switching power and long endurance.  creepage distance conforms to ul and csa standards.  highly noise-resistive insulation materials employed.  standard model available with flux protection construction. ordering information model number legend 1. number of poles 1: 1 pole 2. contact form a: spst-no 3. terminals none: #250 tab/pcb coil terminals p: straight pcb/pcb coil terminals 4. special function e: for long endurance 5. rated coil voltage 5, 12, 24 vdc specifications  coil ratings note: 1. the rated current and coil resistance are measured at a coil temperature of 23 c with a tolerance of 10%. 2. operating characteristics are measured at a coil temperature of 23 c. 3. max. permissible voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. r c x vde classification contact form model #250 tab terminals/pcb coil terminals spst-no g4a-1a-e pcb terminals/pcb coil terminals g4a-1a-pe rated coil voltage note: when ordering, add the rated coil voltage to the model number. example: g4a-1a-e 12 vdc g4a- @@ - @@ @ vdc 1 2 3 4 5 rated voltage 5 vdc 12 vdc 24 vdc rated current 180 ma 75 ma 37.5 ma coil resistance 27.8 w 160 w 640 w coil inductance (ref. value) armature off --- 0.8 h 3.5 h armature on --- 1.1 h 4.8 h must operate voltage 70% of rated voltage max. must release voltage 10% of rated voltage min. max. permissible voltage 160% of rated voltage at (23 ? c) power consumption approx. 0.9 w
2 g4a g4a  contact ratings note: p level:  60 = 0.1 x 10 -6 /operation (with an operating frequency of 120 operations/min)  endurance with motor load with overload with inverter load  characteristics note: the data shown above are initial values. rated load 20 a at 250 vac rated carry current 20 a max. switching voltage 250 vac max. switching current 20 a max. switching power 5,000 va failure rate (reference value) 100 ma at 5 vdc load conditions switching frequency electrical endurance 250 vac: inrush current: 80 a, 0.3 s (cos f = 0.7) break current: 20 a (cos f = 0.9) on: 1.5 s off:1.5 s 200,000 operations load conditions switching frequency electrical endurance 250 vac: inrush current: 80 a (cos f = 0.7) break current: 80 a (cos f = 0.7) on: 1.5 s off:99 s 1,500 operations load conditions switching frequency electrical endurance 100 vac; inrush current: 200 a (0 - p) break current: 20 a on: 3 s off:5 s 30,000 operations contact resistance 100 m w max. operate time 20 ms max. release time 10 ms max. max. operating frequency mechanical: 18,000 operations/hr insulation resistance 1,000 m w min. (at 500 vdc) dielectric strength 4,500 vac 50/60 hz for 1 min between coil and contacts 1,000 vac 50/60 hz for 1 min between contacts of same polarity vibration resistance destruction: 10 to 55 to 10 hz, 0.75-mm single amplitude (1.5-mm double amplitude) malfunction: 10 to 55 to 10 hz, 0.75-mm single amplitude (1.5-mm double amplitude) shock resistance destruction: 1,000 m/s 2 malfunction: 200 m/s 2 endurance mechanical: 2,000,000 operations min. (at 18,000 operations/hr) motor load: 100,000 operations min. (on/off: 1.5 s) inverter load: 30,000 operations min. (on: 3 s, off: 5 s) ambient temperature operating: - 20 c to 60 c (with no icing) ambient humidity operating: 5% to 85% weight approx. 25 g
3 g4a g4a engineering data dimensions note: all units are in millimeters unless otherwise indicated; dimensions shown in parentheses are in inches. maximum switching power endurance switching current (a) endurance (x10 operations) 3 switching voltage (v) switching current (a) ac resistive load ac inductive load cos = 0.4 250-vac resistive load 250-vac inductive load cos = 0.4 5,000 3,000 1,000 700 500 300 100 70 50 terminal arrangement /internal connections g4a-1a-e mounting holes (bottom view) 30.5 max. (30.1)* 16 max. (15.7)* 23.5 max. (23.3)* (top view) (bottom view) tab terminal pcb terminal four, 1.8 +0.1 0 dia. four, 1.8 +0.1 0 dia. 16 max. (15.7)* 26.8 max. (26.5)* 30.5 max. (30.1)* g4a-1a-pe terminal arrangement /internal connections (bottom view) mounting holes (bottom view) *average value *average value
4 g4a g4a precautions mounting when mounting two or more relays side by side, provide a minimum space of 3 mm between relays. terminal connection the terminals fit faston receptacle 250 and are suitable for positive-lock mounting. do not apply excessive force on the terminals when mounting or dismounting the relay. the following positive-lock connectors made by amp are recommended. note: the numbers shown in parentheses are for air-feeding. type receptacle terminals positive housing #250 terminals (width: 6.35 mm) amp 170333-1 (170327-1) amp 170334-1 (170328-1) amp 170335-1 (170329-1) amp 172076-1 natural color amp 172076-4 yellow amp 172076-5 green amp 172076-6 blue all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.03937. to convert grams into ounces, multiply by 0.03527. cat. no. j056-e1-2a


▲Up To Search▲   

 
Price & Availability of G4A-1A-E24VDC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X