vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 aim, universal ac input front end module rev. 2.6 page 1 of 4 set your site on vicor at vicorpower.com vi-aim input voltage compatible dc-dc converter notes 85 C 132 vac vi-x5x-xx used with a 100 C 200 vin converter 180 C 264 vac vi-x6x-xx used with a 200 C 400 vin converter 85 C 264 vac vi-x7x-xx used with a 100 C 375 vin converter parameter rating unit notes maximum value of hold-up capacitance 1200 f thermal resistance 0.4 c/watt baseplate-to-sink operating temperature C 55 to +100 c m-grade storage temperature C 65 to 105 c m-grade transient surge withstand common mode 1.2/50 s, 2 kv pulse, 2 joules en61000-4-5 0 to 360 degree phase angle iec 801-5 normal mode 1.2/50 s, 1 kv pulse, 2 joules with external mov 0 to 360 degree phase angle features ? rohs compliant (ve versions) ? universal input: 85 C 264 vac ? output power: 250 w ? operating temperature: 100c ? efficiency: 97% ? integral emi filtering ? input transient protection ? inrush limiting ? ce marked product highlights the aim (alternating input module) is an ac front-end module which interfaces directly with worldwide ac mains. the aim provides line rectification, emi/rfi filtering, transient protection and inrush limiting in a half bric k package measuring 2.28" x 2.4" x 0.5". the aim is used in conjunction with vicor vi-200 or vi-j00 dc-dc converters to realize a universal ac input, high-density, low-profile switching power supply with outputs from 1 C 95 vdc and a total power rating up to 200 w. an external capacitor is used to satisfy system hold-up requirements. internal emi filtering meets en55022 and fcc part 15, class a emissions limits. actual size: 2.28 x 2.4 x 0.5 in 57,9 x 61,0 x 12,7 mm data sheet vi-aim universal ac input front end module absolute maximum ratings vi - aim - e 1 * part numbering * for mega module packaging option add an l before the product name. example: vx- l aim-xx product grade temperatures (c) grade operating storage e = - 10 to + 100 - 20 to + 100 c = - 25 to + 100 - 40 to + 100 i = - 40 to + 100 - 55 to + 100 m = - 55 to + 100 - 65 to + 100 ac input module product name compliance vi = non rohs ve = rohs
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 aim, universal ac input front end module rev. 2.6 page 2 of 4 set your site on vicor at vicorpower.com specifications (typical at t bp = 25c, nominal line and 75% load, unless otherwise specified) input specifications parameter min typ max unit notes ac line input 85 C 264 1 vac no strapping; no damage below low line 47 C 440 hz inrush current <40 a at peak line (264 vrms ) 1 dependent upon input range of compatible dc-dc converter. output specifications parameter min typ max unit notes output voltage 120 C 373 vdc peak of ac line output power 250 w delivered to converter(s) hold-up time application specific a function of external capacitance and power efficiency 97% safety specifications parameter min typ max unit notes dielectric withstand input to output none provided by dc-dc converter input/output to baseplate 1,500 v rms general specifications parameter min typ max unit notes size 2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7) in (mm) mega module, slimmod and finmod packages available weight 3.0 (85) ounces (grams) agency approvals safety standards agency markings notes conducted emi/rfi vde 0871/fcc part 15, class a with compat ible dc-dc converter modules en55022, class a external 0.47 f capacitor required ul1950, csa 22.2-950, en60950
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 aim, universal ac input front end module rev. 2.6 page 3 of 4 set your site on vicor at vicorpower.com mechanical diagram universal ac in aim gate out pa r gate in +out ?out l2/n nc nc l1 0.47 f ?out ?s trim +s +out +in gate in gate out ?in vi-200/j00 driver load f2 0.01 f (two 4,700 pf) y-rated capacitors 0.01 f (two 4,700 pf) y-rated capacitors 0.01 f ceramic 0.01 f ceramic c1 [a] f1 [a] consult factory or refer to selecting capacitors for aim modules on page 34 of the vi-200 and vi-j00 design guide . z1: mov part #30076 fuse 1: 6.3a/250v (iec 5x20 mm) buss gdb-6.3 or 7 a / 250 v (3ag 1/4" x 1 1/4") littlefuse 314-007 fuse 2: for vi-x7x-xx ? buss pc-tron 2.5 a (250 v) for vi-x6x-xx ? buss pc-tron 3 a (250 v) for vi-x5x-xx ? buss pc-tron 5 a z1 vi-aim block diagram vi-aim connection diagram, typical application emi filter v oc ov vref vref ot ot ate in ate ot parae evel shift d d c n 5 6 7 8 9 4 3 2 1 .080 dia (2) places solder plate over copper alloy .040 (1,0) dia (7) places solder plate over copper alloy .01 aluminum base product id this surface function l1 l2/n +out parallel gate out ?ut pin # 1 2 3 4 5 6 7 8 9 full r +.030 -.000 (5,6) min. .30 min. 1.75 max. 2.40 2.28 .12 .50 1.90 .65 (16,5) .49 (12,4) .30 .015 .15 2.10 (53,4) 1.30 .40 (10,2) .35 .015 (8,9) (0,38) 1.40 (35,6) 1.00 (25,4) .70 (17,8) nc nc gate in vi-aim (57,9) (33,0) (7,6) (0,38) (3,8) .15 (3,8) (48,3) (3,0) .22 (12,7) (0,76) (0) (7,6) (61,0) (44,4)
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 aim, universal ac input front end module rev. 2.6 11/08 set your site on vicor at vicorpower.com vicor corporation 25 frontage road andover, ma, usa 01810 tel: 800-735-6200 fax: 978-475-6715 email customer service: custserv@vicorpower.com technical support: apps@vicorpower.com vicors comprehensive line of power solutions includes high density ac-dc and dc-dc modules and accessory components, fully configurable ac-dc and dc-dc power supplies, and complete custom power systems. information furnished by vicor is believed to be accurate and reliable. however, no responsibility is assumed by vicor for its use. vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. all sales are subject to vicors terms and conditions of sale, which are available upon request. specifications are subject to change without notice. intellectual property notice vicor and its subsidiaries own intellectual property (including issued u.s. and foreign patents and pending patent applications) relating to the products described in this data sheet. interested parties should contact vicor's intellectual property department. warranty vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. this warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. vicor shall not be liable for collateral or consequential damage. this warranty is extended to the original purchaser only. except for the foregoing express warranty, vicor makes no warranty, express or implied, including, but not limited to, the warranty of merchantability or fitness for a particular purpose. vicor will repair or replace defective products in accordance with its own best judgement. for service under this warranty, the buyer must contact vicor to obtain a return material authorization (rma) number and shipping instructions. products returned without prior authorization will be returned to the buyer. the buyer will pay all charges incurred in returning the product to the factory. vicor will pay all reshipment charges if the product was defective within the terms of this warranty. information published by vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. vicor reserves the right to make changes to any products without further notice to improve reliabilit y, function, or design. vicor does not assume any liability arising out of the application or use of any product or circuit; neith er does it convey any license under its patent rights nor the rights of others. vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. per vicor terms and conditions of sale, the user of vicor components in life support applications assumes all risks of such use and indemnifies vicor against all damages.
|