  industrial dc/dc converter c gd i wide input tethys : 3 0w power ? highly configurable dc/dc converter? up to 6 outputs and 3 independant s line regulations ? low profile : 0,33 ? ( 8.5mm)? nominal power of 30 w without derating ? wide temperature range : -40c/+95c case ? galvanic isolation 1.500 vdc ? integrated lc emi filter ? permanent short circuit protection ? external trim and sense adjustment : +/-5% ? inhibit function ? rohs process gaia converter fc97-021.01/10 revision i ? redefining the source of power 1-general industrialgrade for locations, phone, fax, e-mail see back cover 2-product selection input v oltage range 3 : 3.3 vdc5 : 5 vdc 5b : +/-5vdc 12 : 12 vdc 12b : +/-12vdc 15 : 15 vdc 15b : +/-15vdc 24 : 24 vdc 24b : +/- 24vdc permanent d : 4,7-16 vdch : 9-36 vdc j : 16-40 vdc* q : 36-140 vdc** output 5 the tethys 30w wide input series is a full familyof highly configurable dc/dc low profile mo- dule designed for use in distributed power ar- chitecture where variable input voltage and transient are prevalent and are particularly suitable for mobile application in transportation, or high-end industrial areas. this module uses a high frequency fixed swiching technic at 480khz pr ovi din g e x cellen t r eli ability , low n oise characteristics and low profile package. stan-dard models are available with wide input vol- tage range of 4.7-16, 9-36, 16-40 or 36-140 volts. the serie includes thousands of output configuration from single, bi up to six ouput voltages in choice of 3,3, 5, 12, 15, 24 volts with trim and sense functions for output vol- tage adjustment. no external heatsink is required for the cgdi series to supply 30w output power over the full temperature range. all the modules are designed with lc network filters to minimize reflected input current ripple and output voltage ripple. the modules include a soft-start, an inputundervoltage lock-out, a permanent short cir- cuit protection an output overvoltage protection and a thermal protection to ensure efficient module protections. the soft-start allows current limitation and eliminates inrush current during start-up. the short circuit protection completely protects the module against short-circuits of any duration by a shut-down and restores to normal when the overload is removed. the thermal protection is adjusted to 110c and protects the module against overheat. the inhibit function is commanded with a low logic level and disables the module for applica- tions requiring on/off operations. the design has been carried out with surface mount components and is manufactured in a fully automated process to guarantee high qu ality . each m od ule is tested with a g aia converter automated test equipment. 3:1 & 4:1 wide input configurable multiple outputs metallic case - 1.500 vdc isolation transient n / a 40 vdc / 100ms45 vdc / 100ms 175 vdc / 100ms * for 45 vdc consult factory** for 154 vdc consult factory multiple output model : cgdi - input output output output
for locations, phone, fax, e-mail see back cover 2 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 2- product selection (continued) converter selection chart c gd i - q - 5 - 0 - 12b input voltage range : d : 4,7-16 vdch : 9-36 vdc j : 16-40 vdc* q : 36-140 vdc** input voltage range :5 : 5 vdc, 20w first line 12b : +/-12 vdc, 10w second line see table page 1 for complete possibilities input v oltage range designation d h j q output v oltage single line model : cgdi- o o > 30 w first line output : primary output dual line model : cgdi- o > 20 w first line output : primary output > 10 w second line output : secondary output triple line model : cgdi- > 10 w on each line output : primary and secondary outputs permanent 4,7-16 vdc9-36 vdc 16-40 vdc* 36-140 vdc** designation 35 5b12 12b 15 15b 24 24b output v oltage 3.3 vdc 5 vdc +/-5vdc 12 vdc +/-12vdc 15 vdc +/-15vdc 24 vdc +/-24vdc first line output functions : trim function at +/- 5%sense function at +/- 5% tight regulation below 1% indefinite short circuit protection secondary line output functions : independant regulation from primary outputindefinite short circuit protection * for 45 vdc consult factory** for 154 vdc consult factory
for locations, phone, fax, e-mail see back cover 3 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 3- electrical specifications data are valid at +25c, unless otherwise specified. note * : for proper operation the cgdi module requires to install a 22f chemical or tantalum capacitance accross output terminals.note ** : for 9-36v inpt range , the power is derated at 80% at 9v and increases linearly to full power at 12v . note*** : the ripple output voltage is the periodic ac component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered. this noise canbe reduced by adding an e xternal capacitor(typically 10nf/rated voltage depending on isolation requirement) connected between the pin gin and the pin gout o f the converter . this capacitor should be layed-out as close as possible from the converter . note *** : for load regulation characteristics from 0% to full load, please contact factory. parameter conditions limit or typical units cgdi-d cgdi-h input nominal input voltage full temperature range nominal v dc 9 20 permanent input voltage range (ui) full temperature range min. - max. vdc 4,7-16 9-36 extended permanent input voltage range full temperature range (consult factory) min. - max. vdc / / transient input voltage full load maximum vdc/s / 40/0,1 undervoltage lock-out (uvlo) threshold minimum maximum vdc vdc 4 4,5 7 8,5 start up time ui nominal nominal output full load : resistive maximum ms 40 40 reflected ripple current ui nominal, full load at switching freq. bw = 20mhz maximum mapp 50 50 input current in short circuit mode (average) ui nominal short-circuit maximum ma 100 60 no load input current ui nominal no load maximum ma 100 60 primary output output voltage * ui min. to max. 75% load nominal vdc 3,3v , 5v , 12v , 15v or 24v consult factory for other outputs set point accuracy + line regulation + load regulation ambient temperature : +25c ui min. to max. 25% to full load maximum % +/- 1 +/- 1 output power ** full temperature range ui min. to max. maximum w 10, 20 or 30 (limited to respectively 2a, 4a or 6a max) ripple output voltage *** 3,3v and 5v output 12v output 15v and 24v output ui nominal full load bw = 20mhz maximum maximum maximum mvpp mvpp mvpp 40 50 60 40 50 60 trim function ui nominal maximum minimum %% + 5 - 5 + 5 - 5 sense function ui nominal maximum minimum %% + 5 - 5 + 5 - 5 secondary output output voltage * ui min. to max. 75% load nominal vdc 3,3v , 5v , 12v , 15v or 24v +/- 5v , +/- 12v , +/- 15v or +/- 24v consult factory for other outputs set point accuracy ambient temperature : +25c ui nominal, 75% load maximum % +/- 2 +/- 2 output power full temperature range ui min. to max. maximum w 10 or 20 (limited to respectively 2a or 4a max) 10 or 20 (limited to respectively 2a or 4a max) ripple output voltage ** 3,3v, 5v and +/-5v output 12v and +/-12v output 15v and +/-15v output 24v and +/-24v output ui nominal full load bw = 20mhz maximum maximum maximum maximum mvpp mvpp mvpp mvpp 50 100 150 150 50 100 150 150 line regulation ui min. to max. full load maximum % +/- 1 +/- 1 load regulation *** ui nominal 25% to full load maximum % +/- 2,5 +/- 2,5
for locations, phone, fax, e-mail see back cover 4 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 3- electrical specifications (continued) data are valid at +25c, unless otherwise specified. note * : for proper operation the cgdi module requires to install a 22f chemical or tantalum capacitance accross output terminals.note** : the ripple output voltage is the periodic ac component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered. this noise can be reduced by adding an e xternal capacitance (typically 10nf/rated voltage depending on isolation requirement) connected between the pin gin and the pin gout o f the converter . this capacitance should be layed-out as close as possible from the converter . parameter conditions limit or typical units cgdi-j cgdi-q input nominal input voltage full temperature range nominal v dc 28 72 permanent input voltage range (ui) full temperature range min. - max. vdc 16-40 36-140 extended permanent input voltage range full temperature range (consult factory) min. - max. vdc 16-45 36-154 transient input voltage full load maximum vdc/s 45/0,1 1 75/0,1 undervoltage lock-out (uvlo) start up input voltage threshold threshold min. - max. minimum vdc vdc 12-15 / / 33 start up time ui nominal nominal output full load : resistive maximum ms 40 40 reflected ripple current ui nominal, full load at switching freq. bw = 20mhz maximum mapp 50 50 input current in short circuit mode (average) ui nominal short-circuit maximum ma 60 60 no load input current ui nominal no load maximum ma 60 60 primary output output voltage * ui min. to max. 75% load nominal vdc 3,3v , 5v , 12v , 15v or 24v consult factory for other outputs set point accuracy + line regulation + load regulation ambient temperature : +25c ui min. to max. 25% to full load maximum % +/- 1 +/- 1 output power full temperature range ui min. to max. maximum w 10, 20 or 30 ripple output voltage ** 3,3v and 5v output 12v output 15v and 24v output ui nominal full load bw = 20mhz maximum maximum maximum mvpp mvpp mvpp 40 50 60 40 50 60 trim function ui nominal maximum minimum %% + 5 - 5 + 5 - 5 sense function ui nominal maximum minimum %% + 5 - 5 + 5 - 5 secondary output output voltage * ui min. to max. 75% load nominal vdc 3,3v , 5v , 12v , 15v or 24v +/- 5v , +/- 12v , +/- 15v or +/- 24v consult factory for other outputs set point accuracy ambient temperature : +25c ui nominal, 75% load maximum % +/- 2 +/- 2 output power full temperature range ui min. to max. maximum w 10 or 20 10 or 20 ripple output voltage ** 3,3v, 5v and +/-5v output 12v and +/-12v output 15v and +/-15v output 24v and +/-24v output ui nominal full load bw = 20mhz maximum maximum maximum maximum mvpp mvpp mvpp mvpp 50 100 150 150 50 100 150 150 line regulation ui min. to max. full load maximum % +/- 1 +/- 1 load regulation ui nominal 25% to full load maximum % +/- 2,5 +/- 2,5
for locations, phone, fax, e-mail see back cover 5 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 4- switching frequency6- protection functions characteristics protection device recovery limit or ty pical specifications output short circuit protection (scp) hiccup circuitry with auto-recovery automatic recovery permanent see section 12 output overvoltage protection (ovp) zener clamp / maximum maximum maximum maximum for 3.3v : 4v for 5v : 6v for 12v : 14v for 15v : 17v over temperature protection (otp) thermal device with hysteresis cycle automatic recovery nominal 115c 7- reliability data parameter conditions limit or typical specifications switching frequency full temperature range ui min. to max. no load to full load nominal, fixed 4.7-16 vdc input : 480 khz 9-36 vdc input : 480 khz 16-40 vdc input : 480 khz 36-140 vdc input : 430 khz 5- isolation characteristics conditions temperature specifications mean time between failure (mtbf) according to mil-hdbk-217f ground fixed (gf) case at 40c case at 70c 480.000 hrs 190.000 hrs ground mobile (gm) case at 40c case at 70c consult factory mean time between failure (mtbf) according to iec-62380-tr telecom switchers / consult factory parameter conditions limit or typical specifications electric strength test voltage (basic version) inp ut to output minimum 1.500 vdc / 1 min electric strength test voltage between outputs (for outputs of the same line of regulation) output to output minimum no isolation electric strength test voltage between outputs (for outputs of different line of regulation) output to output minimum 500 vdc/ / 1 min. isolation resistance 500 vdc minimum 100 mohm
for locations, phone, fax, e-mail see back cover 6 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 8 - electromagnetic interference electromagnetic interference requirements according to en55022 class a and class b can be easily achieved asindicated in the following table : t o m eet en55022 class b r equir em en ts , ga?a converter recommends the use of front filter (see en55022 class b emi filter design note) together with a common mode noise capacitance c c (10nf/rated voltage depending on isolation requirement) connected between gin and gout. this common mode noise capacitance cc should be layed-out as close as possible fr om th e dc/dc converter . th e typi cal sch em ati c h er eafter d escribes th e t eth ys used in a 4 outputs configuration (exemple 5v/2a, 3.3v/ 2a and+/-15v) with fr on t filter , comm on m od e n oise cc an d out- put capacitance to reduce output ripple voltage. 8 -1 module compliance with en 55022 class b 100k input filter kg9502 common mode noise capacitance c = 10nf c tethys vi + vo1 gi - vo1 c4 c2 c3 l2 c1 l1 - input + input gin command + vo2 - vo2 + vo3 - vo3 common 3 + vo1 0v + vo2 0v + vo3 - vo3 0v 22f 22f 22f 22f case on/off electromagnetic interference according to en55022 conducted noise emission configuration with common mode capacitor c c = 10nf and input capacitor c i with common mode capacitor c c = 10nf and external filter models 4,7-16v input models class a, c i =10f/ 35 v tantalum + inductance 4,7 mh class b 9-36v input models class a, c i =4,7f/ 50 v tantalum class b 16-40v input models class a, c i =4,7f/ 50 v tantalum class b 36-140v input models class a, c i =47f / 200 v tantalum / radiated noise emission configuration with common mode capacitor c c = 10 nf models all models class b
for locations, phone, fax, e-mail see back cover 7 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 9- surge susceptibility en61000-4-5 & en50155surge susceptibility requirements according to en50155, en61000-4-5 and electromagnetic interference requirements of en55022 class a can easily be achieved using either : ? a limitor module lgds-50 series : ready-to-use single module solution,? an input limitor filter : schematics of discret components, to sustain the following surge levels : 9-1 surge protection with off-the-shelf solution : lgds-50 limitor modulet o sustain sur g e r equir em en ts o f en61000-4-5, an d en50155 tog eth er with en55022 class a, g a?a converter pr oposes a ready-to-use single product. depending on bus input range two references of limitor module are existing with referencesas follow : these modules designated lgds-50 series are designed up to 50w power and will protect c gdi series with 9-36, 16-40 or 36- 140 vdc input against surges.the implantation of lgds-50 with modules can be undertook as follow : 9-2 surge protection with discrete components t o sustain sur g e r equir em en ts o f en61000-4-5 an d en50155 tog eth er with en55022 class a, g a?a converter pr opo- ses th e f ollowin g fr on t pr otecti on filter . please consult en50155 transient/emi filter design note for further details.* note : value of common mode noise capacitance rated voltage depends on isolation requirements. please consult lgds-50 datasheet for further details. cgdi - series vi vo gi go cgdi - series vi vo gi go lgds-50 - input + input - input + input cgdi - series vi vo gi go * common mode noise capacitance c = 10nf c f1 d1 c1 c2 l1 d2 d3 d4 d5 characteristics standards levels spikes line to line en 61000-4-5 level 4 with 4.000 v waveform 50 s, im pedance 2 ohm en 50155 level 1.800 v waveform 50 s, impedance 100 and 5 o hm level 8.400 v waveform 0.1 s, impedance 100 ohm spikes line to earth en 61000-4-5 level 4 with 4.000 v waveform 50 s, im pedance 12 ohm en 50155 level 1.800 v waveform 50 s, impedance 100 and 5 o hm level 8.400 v waveform 0.1 s, impedance 100 ohm input types dc/dc converter family limitor module ref erence 9-36 vdc input 16-40 vdc input 36-140 vdc input cgdi-10-h series cgdi-10-j series cgdi-10-q series lgds-50-j-k lgds-50-j-k lgds-50-q-k
for locations, phone, fax, e-mail see back cover 8 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 10- thermal characteristics characteristics conditions limit or typical performanc es operating ambient temperature range at full load ambient temperature * minimum maximum - 40c + 71c operating case temperature range at full load case temperature minimum maximum - 40c +95c storage temperature range non functionning minimum maximum - 40c + 105c thermal resistance rth case to ambient in free air natural convection typical 4c /w note * : the upper temperature range depends on configuration, the user must assure a max. case temperature of + 95c. 10 100 30 80 70 60 90 20 40 50 25% 75%50% 100% power (w) temperature ( ?c) full load ambient temperature without derating : 71?c maximum case temperature : 95?c natural convection operation area additionnal cooling operation area maximum storage temperature : 105?c the cgdi series operating case temperature must not exceed 95c. the maximum ambient temperature admissible for the dc/dc converter corr espon din g to th e m axim um oper atin g case temper atur e o f 95c d epen ds on th e ambi en t airflow , th e mounting/orientation, the cooling features and the power dissipated.t o calculate a m axim um ad missible ambi en t temper atur e th e f ollowin g m eth od can be used . kn owin g th e m axim um case tempar atur e t case = 95c o f th e m od ule , th e power used p out an d th e effi ci en c y : ? determine the power dissipated by the module pdiss that should be evacuated : pdiss = pout(1/ ? ? - 1) ? determine the maximum ambient temperature : t a = 95c - rth x pdiss where rth is the thermal resistance from the case to ambient . the previous thermal calculation shows two areas of operation : ? a normal operation area in a free natural ambient convection (grey area in this following graph),? an area with cooling features (air flow or heatsink) ensuring a maximum case temperature below the maximum operating case temperature of 95c (white area in the following graph).
for locations, phone, fax, e-mail see back cover 9 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 11- environmental qualificationsthe modules have been subjected to the following environmental qualifications. characteristics conditions severity test procedure climatic qualifications life at high temperature duration temperature status of unit 1.000 hrs 95c case unit operating iec 68-2-2 humidity steady damp heat temperature duration status of unit 93 % relative humidity 40c 56 days unit not operating iec 68-2-3 test ca temperature cycling number of cycles temperature change transfert time steady state time status of unit 200 -40c / +71c 40 min. 20 min. unit not operating iec 68-2-14 test n temperature shock number of shocks temperature change transfert time steady state time status of unit 50 -40c / +105c 10 sec. 20 min. unit not operating iec 68-2-14 test na mechanical qualifications vibration (sinusoidal) number of cycles frequency : amplitude frequency : acceleration amplitude /acceleration duration status of unit 10 cycles in each axis 10 to 60 hz / 0.7 mm 60 to 2000 hz / 10 g 0.7 mm/10 g 2h 30 min. per axis unit not operating iec 68-2-6 test fc shock (half sinus) number of shocks peak acceleration duration shock form status of unit 3 shocks in each axis 100 g 6 ms 1/2 sinusoidal unit not operating iec 68-2-27 test ea bump (half sinus) number of bumps peak acceleration duration status of unit 2000 bumps in each axis 25 g 6 ms unit not operating iec 68-2-29 test eb electrical immunity qualifications electrical discharge susceptibility number of discharges air discharge level contact discharge level air discharge level contact discharge level 10 positive & 10 negative discharges 4 kv : sanction a 2 kk : sanction a 8 kk : sanction b 4 kv : sanction b en55082-2 with : en61000-4-2 iec 801-2 electrical field susceptibility antenna position electromagnetic field wave form signal frequency range at 1 m 10 v/m am 80%, 1 khz 26 mhz to 1 ghz en55082-2 with : en61000-4-3 iec801-3 electrical fast transient susceptibility burst form wave form signal impedance level 1 level 3 5/50 ns 5 khz with 15 ms burst duration period 300 ms 50 ohm 0,5 kv : sanction a 2 kv : sanction b en55082-2 with : en61000-4-4 iec801-4 surge susceptibility surge form impedance level 4 1,2/50 s 2 ohm 4 kv : with transient protection or lgds-50 limitor module (see section surge) en61000-4-5 en50155
for locations, phone, fax, e-mail see back cover 10 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 12- description of protections12-1 input undervoltage lock-out (uvlo) the input undervoltage lock-out protection device turns- on and turns-off the output voltage when the input bus voltage reaches the undervoltage lock-out threshold. there is no hysteresis cycle at turn-on and turn-off. 12-2 output short circuit protection (scp) the short circuit protection device protects the moduleagainst short circuit of any duration and restores the mo- dule to normal operation when the short circuit is removed. it operates in ?hiccup? mode by testing periodically if an overload is applied (typically every 200ms recovery time). the overload detection threshold is typically 200% of maxi- mum current with a detection time lower than 5ms. 12-3 output overvoltage protection (ovp) the output overvoltage protection device protects external components against high voltage or possible overvoltages which can be supplied by the module (i.e in case of internal failure). it consists of a zener diode clamping the output voltage; under worst case conditions this zener diode will short-circuit. the output voltage protection is not designed to withstand externally applied output overvoltages to protect the mo- dule itself. 12-4 ov er t emper atur e pr otection (o tp) a thermal protection device adjusted at 115c (+/-5%)internal temperature with 10c hysteresis cycle will inhibit the module as long as the overheat is present and restores to normal operation automatically when overheat is removed. the efficiency of the otp function is warranty with the module mounted on a heatsink. time recovery time detection time recovery time x 100 vo (%) baseplate temperature on 115 ?c off 10?c vin on off uvlo turn-on/turn-off
for locations, phone, fax, e-mail see back cover 11 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 13- description of functions13-1 on/off function the control pin 16 (on/off) can be used for applications requiring on/off operation. by using an open collector command with a transistor q referenced to the common terminal (gi) : ? a logic pulled low (<0.2v@1ma, referenced to gi)on pin 16 disables the converter ? no connection or high impedance on pin 16 enables th e converter . by releasing the on/off function, the converter will restartwithin the start-up time specifications given in table page 3. for further details please consult ??logic on/off?? applica- tion note. 13-2 trim function the primary output voltage vo1 may be trimmed at +/-5% vi a a sin gle e xtern al trimpot or fix ed r esistor . th e trimpot sh ould be conn ected as sh own in fi gur e h er eafter . value of the trim resistance is given in the followingtable : 13-3 sense function if the load is seperated from the output by any line lenght, some of these performance characteristics will be degraded at the load terminals by an amount proportional to the impedance of the load leads. with the sense function, the voltage at the power supply output shifts by up to the maximum allowed voltage per load line to compensate the voltage drop in the load leads, there by maintaining a constant voltage at the load terminals. both trim and sense function can be combined but the compensation voltage must not exceed 0.5v max or +/- 5% of the output voltage. 1 sense+ vo1 load trim go1 sense- 2 5 6 3 r1 10k vo1 r1 value vo1 r1 value 2,5 v 0 ohm 12 v 12 kohm 3,3 v 0 ohm 15 v 22 kohm 5 v 0 ohm 24 v 36 kohm gi on/off command 1 sense+ vo1 load trim go1 sense- 2 5 6 3
for locations, phone, fax, e-mail see back cover 12 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 t eth ys seri es can be used in par allel to in cr ease output power . up to 3 t eth ys can be used to ad d power up to a m axim um o f 90w . con tact f actory f or furth er d etails . 14-1 p ar allel oper ations 14- application notes
for locations, phone, fax, e-mail see back cover 13 industrialgrade cgdi wide input tethys series gaia converter fc97-021.01/10 revision i ? 5 18- connections 15- dimensionsdim en si on ar e given in mm (in ch es). t oler an ce : +/- 0,2 mm (+/- 0.01 ?) unless oth erwise in di cated . weight : 85 grams (2.9 ozs) max. 27,94 (1.1") 50,80 (2") 76,30 (3") 82,40 (3.25") 2x5,08 (2x0.2") 2x5,08 (2x0.2") 5x2,54 (5x0.1") 1x5,08 (1x0.2") 1x5,08 (1x0.2") 40,64 (1.6") 4 holes m3 8,6 (0.33") 0,3 min (0.001") 48,26 (1.9") 49,9 (1.96") 56.00 (2.2") 10 (0.39") pin dimensions : o 0,83mm (0.032") * except pin 15 : 6 mm (0.23") long 5 (0.19")* +/-1 7,2 +/-0,4 (0.28") 1,45 +/-0,4 (0.06") s i n g l e l i n e d u a l l i n e t r i p l e l i n e 1 o u t p u t 2 o u t p u t s 3 o u t p u t s 4 o u t p u t s 5 o u t p u t s 6 o u t p u t s pin cgdi - - - 0 - 0 cgdi - - - 0 - cgdi - - - - 0 cgdi - - - 0 - cgdi - - - - cgdi - - - - cgdi - - - - cgdi - - - - 1 ouput 1 + (+vo1) output 1 + (+vo1) output 1 + (+vo1) output 1 + (+vo1) output 1 + (+vo1) output 1 + (+vo1) output 1 + (+vo1) output 1 + (+vo1) 2 sense + sense + sense + sense + sense + sense + sense + d o not connect 3 trim trim trim trim trim trim trim do not connect 4 do not connect do not connect do not connect do not c onnect do not connect do not connect do not connect ret urn 1 (go1) 5 sense - sense - sense - sense - sense - sense - sense - d o not connect 6 return 1 (go1) return 1 (go1) return 1 (go1) return 1 - (go1) return 1 (go1) return 1 (go1) return 1 (go1) ou tput 1 - (-vo1) 7 do not connect do not connect output 2+ (+vo2) do not connect output 2 + (+vo2) output 2 + (+vo2) output 2 + (+vo2) output 2 + (+vo2) 8 do not connect do not connect do not connect do not c onnect do not connect do not connect return 2 (go2) ret urn 2 (go2) 9 do not connect do not connect return 2 (go2) do not c onnect return 2 (go2) return 2 (go2) output 2 - (-vo2) output 2 - (-vo2) 10 do not connect output 2+ (+vo2) do not connect outpu t 2+ (+vo2) output 3 + (+vo3) output 3 + (+vo3) output 3 + (+vo3) output 3 + (+vo3) 11 do not connect do not connect do not connect return 2 (go2) do not connect return 3 (go3) return 3 (go3) re turn 3 (go3) 12 do not connect return 2 (go2) do not connect output 2- (-vo2) return 3 (go3) output 3 - (-vo3) output 3 - (-vo3) output 3 - (-vo3) 13 - input (gi) - input (gi) - input (gi) - input (gi) - input (gi) - input (gi) - input (gi) - input (gi) 14 + input (vi) + input (vi) + input (vi) + input (vi) + input (vi) + input (vi) + input (vi) + input (vi) 15 case case case case case case case case 16 on/off on/off on/off on/off on/off on/off on/off on/off 16- materialscase : matallic black anodized coating. pins : plated with pure matte tin over nickel underplate. 17- product marking upper face : company logo, location of manufacturing. side face : module reference, option, date code : year and week of manufacturing.
inf orm ati on given in this d atash eet is beli eved to be accur ate an d r eli able . h owever , no r espon sibility is assum ed f or th e con sequen ce o f its use n or f or an y infrin g em en t o f paten ts or oth er ri gh ts o f thir d parti es whi ch m ay r esult fr om its use . th ese pr od u cts ar e sold only accor din g to g aia converter g ener al con diti on s o f sale , unless oth erwise confirm ed by writin g. specifi cati on s subject to chan g e with out n otice . printed in france by gaia converter fc97-021.01/10 revision j graphisme : philippe clicq repr esen ted by : for m or e d etailed specifi cati on s an d appli cati on s inf ormati on, con tact : international headquarter s ga?a converter - france zi de la morandire 33185 le haillan - france t el. : + (33)-5-57-92-12-80 fax : + (33)-5-57-92-12-89 north american headquarter s ga?a converter canada, inc4038 le corbusier la v al, quebec - canad a h7l 5r2 t el. : (514)-333-3169 fax : (514)-333-4519


▲Up To Search▲   

 
Price & Availability of CGDI-Q-5B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X