s134 page 1 specifications are subject to change without notice ?2003 teledyne relays www.teledynerelays.com s134/1203/q1 centigrid ? and to-5 series s134 centigrid ? surface mount commercial relays sensitive dpdt description the series s134 sensitive surface mount centigrid ? relay is an ultraminiature, hermetically sealed, armature relay. the low profile height (.460") and .100" lead spacing make it ideal for applications where extreme packaging density and/or close pc board spacing are required. the specially formed leads are pre-tinned to make the relays ideal for most types of surface mount solder reflow processes. the basic design and internal construction are identical to the series 134 centigrid ? relays, and are capable of meeting teledyne relays t 2 r ? requirements. the following unique construction features and manufacturing techniques provide overall high reliability and excellent resistance to environmental extremes: ? all welded construction. ? unique uni-frame design providing high magnetic efficiency and mechanical rigidity. ? high force/mass ratios for resistance to shock and vibration. ? advanced cleaning techniques provide maximum assurance of internal cleanliness. ? precious metal alloy contact material with gold plating assures excellent high current and dry circuit switching capabilities. the series s134d and s134dd relays have internal discrete silicon diodes for coil suppression and polarity reversal protection. the sensitive surface mount centigrid ? relay has a high resistance coil, thus requiring extremely low operating power (200 mw typical). the advantages of reduced heat dissipation and power supply demands are a plus. internal construction series designation relay type s134 dpdt basic relay s134d dpdt relay with internal diode for coil transient suppression s134dd dpdt relay with internal diodes for coil transient suppression and polarity reversal protection uni-frame armature upper stationary contact lower stationary contact moving contact environmental and physical specifications temperature (ambient) storage C65c to +125c operating C55c to +85c vibration (general note 1) 30 gs to 3000 hz shock (general note 1) 75 gs, 6 msec, half-sine acceleration 50 gs enclosure hermetically sealed weight 0.15 oz. (4.3g) max. reflow temperature 260c max. temp. 1 min. max.
?2003 teledyne relays specifications are subject to change without notice s134 page 2 www.teledynerelays.com s134/1203/q1 centigrid ? and to-5 300 250 200 150 100 50 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 load current (amps dc) figure 1 typical dc contact rating (resistive) (note 2) load voltage (vdc) series s134 general electrical specifications (C65c to +125c unless otherwise noted) (notes 2 & 3) detailed electrical specifications (C65c to +125c unless otherwise noted) (note 3) contact arrangement 2 form c (dpdt) rated duty continuous contact resistance 0.1 ohm max. before life; 0.2 ohm max. after life at 1a/28vdc (measured 1/8" from header) contact load ratings (dc) (see fig. 2 for other dc resistive voltage/current ratings) resistive: 1 amp/28vdc inductive: 200 ma/28vdc (320 mh) lamp: 100 ma/28vdc low level: 10 to 50 a/10 to 50mv contact load ratings (ac) resistive: 250 ma/115vac, 60 and 400 hz (case undergrounded) 100 ma/115vac, 60 and 400 hz (case grounded) contact life ratings 10,000,000 cycles (typical) at low level 1,000,000 cycles (typical) at 0.5a/28vdc resistive 100,000 cycles min. at all other loads specified above contact overload rating 2a/28vdc resistive (100 cycles min.) contact carry rating contact factory coil operating power 200 milliwatts typical at nominal rated voltage @ 25c operate time 4.0 msec max. at nominal rated voltage @ 25c release time s134 series: 2.0 msec max. s134d, s134dd series: 7.5 msec max. contact bounce 1.5 msec max. intercontact capacitance 0.4 pf typical insulation resistance 10,000 megohms min. between mutually isolated terminals dielectric strength atmospheric pressure: 500 vrms/60hz 70,000 ft.: 125 vrms/60hz negative coil transient (vdc) s134d, s134dd 1.0 max diode p.i.v. (vdc) s134d, s134dd 100 min. base part numbers (see note 10 for full p/n example) s134-5 s134d-5 s134dd-5 s134-6 s134d-6 s134dd-6 s134-9 s134d-9 s134dd-9 s134-12 s134d-12 s134dd-12 S134-18 s134d-18 s134dd-18 s134-26 s134d-26 s134dd-26 coil voltage (vdc) nom. 5.0 6.0 9.0 12.0 18.0 26.5 max. 7.5 10.0 15.0 20.0 30.0 40.0 coil resistance (ohms 10% @25c) s134, s134d 100 200 400 800 1600 3200 s134dd (note 4) 64 125 400 800 1600 3200 coil current (madc @25c) (134dd series) note 5 min. 56.8 36.3 18.1 12.5 9.6 7.2 max. 78.1 48.9 23.6 16.0 12.2 9.0 pick-up voltage (vdc, max.) s134, s134d 3.5 4.5 6.8 9.0 13.5 18.0 s134dd 3.7 4.8 8.0 11.0 14.5 19.0 drop-out voltage (vdc) s134, s134d min. 0.12 0.18 0.35 0.41 0.59 0.89 max. 2.5 3.2 4.9 6.5 10.0 13.0 s134dd min. 0.7 0.8 0.9 1.0 1.1 1.3 max. 2.6 3.0 4.5 5.8 9.0 13.0
s134 page 3 specifications are subject to change without notice ?2003 teledyne relays www.teledynerelays.com s134/1203/q1 centigrid ? and to-5 .335 max (8.51) .031 ref (.79) 4 max typ 4 max typ .035 ref (.89) .045 min 8 pl (1.14) .100 4 pl (2.54) .200 (5.08) .100 typ (2.54) .375 max (9.53) .460 max (11.68) dimensions are shown in inches (millimeters) ?.017 ref (.43) 2 2 typ .378 +.030 C.020 typ 9.60 +.76 C.51 () .200 (5.08) (note 6) .375 sq max (9.53) .200 (5.08) .410 min (10.41) outline dimensions and recommended pad layout (notes 7, 8 & 9) general notes 1. relay contacts will exhibit no chatter in excess of 10 sec or transfer in excess of 1 sec. 2. typical characteristics are based on available data and are best estimates. no on-going verification tests are performed. 3. unless otherwise specified, parameters are initial values. 4. for reference only. coil resistance not directly measurable at relay terminals due to internal series semiconductor. 5. measured at nominal voltage for 5 sec. max. 6. position of leads as they emerge from relay base. 7. leads will fit noted pad layout with no overhang. 8. lead ends are coplanar within .008" wide tolerance zone. 9. terminals coated with sn60 or sn63 solder per qq-s-571. kovar exposed at sheared end of leads. 10. 6 5 43 7 8 1 2 s134 s134d s134dd 6 5 43 7 8 1 2 () (+) 6 5 43 7 8 1 2 () (+) terminal locations & schematic diagrams schematics are viewed from terminals series s134 teledyne part numbering system for surface mount relays surface mount s 134 d - 26 series no. d = suppression diode dd = suppression and polarity protection diodes coil voltage 11. add "/r" to end of part number for rohs compliant solder coated pins (sn99.3/cu0.7).
pad designation and bottom view dimensions height for use with the following: dim. h max. m4 pad for to-5 er411t er412, er412d, er412dd .295 (7.49) 712, 712d, 712tn, rf300, rf310, rf320 .300 (7.62) er420, er422d, er420dd, 421, er421d, er421dd, er422, er422d, er422dd, 722, 722d, rf341 .305 (7.75) er431t, er432t, er432, er432d, er432dd .400 (10.16) 732, 732d, 732tn, rf303, rf313, rf323 .410 (10.41) rf312 .350 (8.89) m4 pad for to-5 er411, er411d, er411dd .295 (7.49) er431, er431d, er431dd .400 (10.16) rf311 .300 (7.62) rf331 .410 (10.41) m4 pad for centigrid ? 172, 172d .305 (7.75) er114, er114d, er114dd, j114, j114d, j114dd .300 (7.62) er134, er134d, er134dd, j134, j134d, j134dd .400 (10.16) rf100 .315 (8.00) rf103 .420 (10.67) m9 pad for centigrid ? 122c, a152 .320 (8.13) er116c, j116c .300 (7.62) er136c, j136c .400 (10.16) rf180 .325 (8.25) a150 .305 (7.75) notes: 1. spacer pad material: polyester lm. 2. to specify an m4 or m9 spacer pad, refer to the mounting variants portion of the part numbering example in the applicable datasheet. 3. dimensions are in inches (mm). 4. unless otherwise speci ed, tolerance is .010 (.25). 5. add 10 m to the contact resistance show in the datasheet. 6. add 0.01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet. ?.150 [3.81] (ref) dim h max dim h max dim h max .156 [3.96] (ref) .256 [6.5] (ref) dim h max appendix a: spacer pads ? 2008 teledyne relays specifications subject to change without notice
pad designation and bottom view dimensions height for use with the following: dim. h max. m pad 5/ 6/ er411t, j411t, er412, er412d er412dd, j412, j412d, j412dd er412t, j412t .388 (9.86) 712, 712d, 712tn .393 (9.99) er431t, j431t, er432, er432d er432dd, j432, j432d, j432dd er432t, j432t .493 (12.52) 732, 732d, 732tn .503 (12.78) er420, j420, er420d, j420d er420dd, j420dd, er421, j421 er421d, j421d, er421dd j422d, er422dd, j422dd, 722 .398 (10.11) m2 pad 7/ 8/ er411t er412, er412d, er412dd j412, j412d, j412dd .441 (11.20) 712, 712d .451 (11.46) er421, er421d, er421dd 722, 732d .451 (11.46) er431t er432, er432d, er432dd .546 (13.87) 732, 732d .556 (14.12) m3 pad 5/ 6/ 9/ er411, er411d, er411dd er411tx er412x, er412dx, er412ddx er412tx .388 (9.86) 712x, 712dx, 712tnx .393 (9.99) er420x, er420dx, er420ddx er421x, er421dx, er421ddx er422x, er422dx er422ddx, 722x, 722ddx .398 (10.11) er431, er431d, er431dd er431tx er432x, er432dx, er432ddx er432tx .493 (12.52) 732x, 732dx, 732tnx .503 (12.78) notes: 1. spreader pad material: diallyl phthalate. 2. to specify an m, m2 or m3 spreader pad, refer to the mounting variants portion of the part number example in the applicable datasheet. 3. dimensions are in inches (mm). 4. unless otherwise speci ed, tolerance is .010 (0.25). 5/. add 25 m to the contact resistance shown in the datasheet. 6/. add .01 oz. (0.25 g) to the weight of the relay assembly shown in the datasheet. 7/. add 50 m to the contact resistance shown in the datasheet. 8/. add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet. 9/. m3 pad to be used only when the relay has a center pin (e.g. er411m3-12a, 722xm3-26.) .370 [9.4] max sq .150 [3.81] .100 [2.54] .200 [5.08] .300 [7.62] .100 [2.54] dim h max .370 [9.4] min .014 [0.36] (ref) .390 [9.91] sq .300 [7.62] .100 [2.54] .300 [7.62] .100 [2.54] .150 [3.81] .150 [3.81] .130 [3.3] dim h max .370 [9.4] max sq .150 [3.81] .100 [2.54] .200 [5.08] .300 [7.62] .100 [2.54] dim h max .370 [9.4] min .014 [0.36] (ref) appendix a: spreader pads (800) 284-7007 ? www.teledynerelays.com +44 (0) 1236 453124 ? www.teledyne-europe.com ? 2008 teledyne relays
.100 [2.54] .100 [2.54] .100 [2.54] "y" position "z" position .100 [2.54] .100 [2.54] .100 [2.54] "w" position "u" position (er116c and er136c only) "x" position "z" position "y" position .050 [1.27] 36 3 ?.200 [?5.08] "z" position "y" position "x" position 45 3 "z" position "y" position ?.200 [?5.08] centigrid? relays: rf100, rf103, er114, er134, 172 centigrid? relays: rf180, er116c, 122c, er136c to-5 relays: er411t, er412, er412t, er420, er421, er422, er431t, er432, er432t, 712, 712tn, 400h, 400k, 400v, rf300, rf303, rf341, rf312, rf310, rf313, rf320, rf323 to-5 relays: er411, er431, rf311, rf331 notes 1. terminal views shown 2. dimensions are in inches (mm) 3. tolerances: .010 (.25) unless otherwise speci ed 4. ground pin positions are within .015 (0.38) dia. of true position 5. ground pin head dia., 0.035 (0.89) ref: height 0.010 (0.25) ref. 6. lead dia. 0.017 (0.43) nom. indicates ground pin position indicates glass insulated lead position indicates ground pin or lead position depending on relay type appendix a: ground pin positions ? 2008 teledyne relays specifications subject to change without notice
|