Part Number Hot Search : 
ADV7330 DS332 LB1833M UPC1701 FJF9LD 271M8MX 2SD20 LSZ52K
Product Description
Full Text Search
 

To Download C-13-1250C-TDFB3-SSC4E Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  1 1.25 gbps single mode transceiver c-1x-1250(c)-tdfb(3)-ssc(2/3/4) 1 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 lumnds602-may1006 rev a.4 luminentoic.com features ? sc duplex single mode transceiver ? industry standard 1x9 footprint ? gigabit ethernet compliant ? single +3.3/5v power supply ? pecl differential inputs and outputs ? pecl/lvpecl signal detection output [c-1x-1250-tdfb(3)-ssc(2/3/4)] ? ttl/lvttl signal detection output [ c-1x-1250c-tdfb(3)-ssc(2/3/4)] ? wave solderable and aqueous washable ? uncooled laser diode with mqw structure ? complies with telcordia (bellcore) gr-468-core ? gigabit ethernet application ? rohs compliance available parameter symbol min. max. unit note power supply voltage v cc 0 3.6 v c-1x-1250(c)-tdfb3-ssc(2/3/4) power supply voltage v cc 0 6 v c-1x-1250(c)-tdfb-ssc(2/3/4) output current i out 0 30 ma soldering temperature - - 260 oc 10 seconds on leads only storage temperature t stg -40 85 oc absolute maximum rating parameter symbol min. typ. max. unit power supply voltage 1 v cc 3.1 3.3 3.5 v power supply voltage 1 v cc 4.75 5 5.25 v operating temperature 1 (case) t opr 0 - 70 oc operating temperature 1 (case) t opr -40 - 85 oc data rate - - 1250 - mbps recommended operating condition note1: please refer to ordering information
2 1.25 gbps single mode transceiver c-1x-1250(c)-tdfb(3)-ssc(2/3/4) 2 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 lumnds602-may1006 rev a.4 luminentoic.com parameter symbol min typical max unit notes optical transmit power p o -9.5 - -3 dbm c-1x-1250(c)-tdfb(3)-ssc optical transmit power p o -5 - 0 dbm c-1x-1250(c)-tdfb(3)-ssc2 optical transmit power p o -3 - +2 dbm c-1x-1250(c)-tdfb(3)-ssc3 optical transmit power p o 0 - +5 dbm c-1x-1250(c)-tdfb(3)-ssc4 output center wavelength 1280 1310 1340 nm c-13-1250(c)-tdfb(3)-ssc(2/3/4) output center wavelength 1520 1550 1580 nm c-15-1250(c)-tdfb(3)-ssc(2/3/4) output spectrum width ? - - 1 nm -20 db width side mode suppression ratio smsr 30 35 - db extinction ratio er 9 - - db output eye compliant with ieee 802.3 optical rise time t r - - 0.26 ns 20% to 80% values optical fall time t f - - 0.26 ns 20% to 80% values relative intensity noise rin - - -120 db/hz total jitter tj - - 0.27 ns measured with 2 7 -1 prbs transmitter speci?cations (optical) parameter symbol min typical max unit notes power supply current i cc - - 180 ma maximum current is speci?ed at vcc= maximum @ maximum temperature data input current-low i il -350 - - a data input current-high i ih - - 350 a differential input voltage v ih -v il 300 - - mv data input voltage-low v il -v cc -2.0 - -1.58 v these inputs are compatible with 10k, 10kh and 100k ecl and pecl inputs data input voltage-high v ih -v cc -1.1 - -0.74 v transmitter speci?cations (electrical)
3 1.25 gbps single mode transceiver c-1x-1250(c)-tdfb(3)-ssc(2/3/4) 3 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 lumnds602-may1006 rev a.4 luminentoic.com parameter symbol min typical max unit notes sensitivity 2 - - - -24 dbm maximum input power p in 0 - - dbm signal detect-asserted pa - - -24 dbm measured on transition: low to high signal detect-deasserted pd -38 - - dbm measured on transition: high to low signal detect-hysteresis 1 - - db wavelength of operation 1100 - 1600 nm note 2: measured with 2 7 -1 prbs, ber= 10 -12 receiver speci?cations (optical) parameter symbol min typical max unit note power supply current i cc - - 100 ma the current excludes the output load current data output voltage-low v ol -v cc -2.0 - -1.58 v these outputs are compatible with 10k, 10kh and 100kecl and lvpecl outputs data output voltage-high v oh - v cc -1.1 - -0.74 v signal detect output voltage-low v sdl - - 0.5 v c-1x-1250c-tdfb(3)-ssc(2/3/4) signal detect output voltage-high v sdh 2.0 - - v signal detect output voltage-low v sdl- v cc -2.0 - -1.58 v c-1x-1250-tdfb(3)-ssc(2/3/4) signal detect output voltage-high v sdh- v cc -1.1 - -0.74 v receiver speci?cations (electrical)
4 1.25 gbps single mode transceiver c-1x-1250(c)-tdfb(3)-ssc(2/3/4) 4 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 lumnds602-may1006 rev a.4 luminentoic.com pin symbol notes 1 rxgnd directly connect this pin to the receiver ground plane 2 rd+ see recommended circuit schematic 3 rd- see recommended circuit schematic 4 sd active high on this indicates a received optical signal 5 rxvcc +3.3v/5v dc power for the receiver section 6 txvcc +3.3v/5v dc power for the transmitter section 7 td- see recommended circuit schematic 8 td+ see recommended circuit schematic 9 txgnd directly connect this pin to the transmitter ground plane connection diagram 1. (rx gnd) 2. (rx +) nc 3. (rx-) 4. (sd) 5. (rx vcc) top view 6. (tx vcc) 7. (tx-) nc 8. (tx+) 9. (tx gnd) receiver signal ground receiver data out receiver data out bar signal detect receiver power supply transmitter power supply transmitter data in bar transmitter data in transmitter signal ground
5 1.25 gbps single mode transceiver c-1x-1250(c)-tdfb(3)-ssc(2/3/4) 5 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 lumnds602-may1006 rev a.4 luminentoic.com 1 2 3 4 5 9 7 8 6 rx vcc tx vcc transceiver top view no internal connection no internal connection c2 c1 c4 l2 c3 l1 rx vcc tx vcc vcc tx vcc rx vcc rd + rd - sd td + td - r8 r10 r9 r7 c6 c5 r1 r3 r2 r4 r5 r6 notes +3.3v: r1=r3=r5=r7=r9=130 ? r2=r4=r6=r8=r10=82 ? c1=c2=c3=c5=c6=0.1 ? f c4=10 ? f l1=l2=1 ? h notes +5v: r1=r3=r5=r7=r9=82 ? r2=r4=r6=r8=r10=130 ? c1=c2=c3=c5=c6=0.1 ? f c4=10 ? f l1=l2=1 ? h recommended circuit schematic the split-loaded terminations for ecl signals need to be located at the input of devices r eceiving those ecl signals. the power supply ?ltering is required for good emi performance. use short tracks from the inductor l1/l2 to the module rx vcc. a gnd plane under the module is required for good emi and sensitivity performance. 1 2 3 4 5 9 7 8 6 rx vcc tx vcc transceiver top view no internal connection no internal connection c2 c1 c4 l2 c3 l1 rx vcc tx vcc vcc tx vcc rx vcc rd + rd - sd td + td - r6 r8 r7 c6 c5 r1 r3 r2 r4 r5 notes +3.3v: r1=r3=r5=r7=130 ? r2=r4=r6=r8=82 ? c1=c2=c3=c5=c6=0.1 ? f c4=10 ? f l1=l2=1 ? h notes +5v: r1=r3=r5=r7=82 ? r2=r4=r6=r8=130 ? c1=c2=c3=c5=c6=0.1 ? f c4=10 ? f l1=l2=1 ? h c-1x-1250c-tdfb(3)-ssc(2/3/4) c-1x-1250-tdfb(3)-ssc(2/3/4)
6 1.25 gbps single mode transceiver c-1x-1250(c)-tdfb(3)-ssc(2/3/4) 6 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 lumnds602-may1006 rev a.4 luminentoic.com package diagram front view side view top view rear view units: mm package option: blank, a = black case
7 1.25 gbps single mode transceiver c-1x-1250(c)-tdfb(3)-ssc(2/3/4) 7 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 lumnds602-may1006 rev a.4 luminentoic.com side view rear view x8 top view front view units: mm package diagram package option : b, e = blue case c, d = black case
8 1.25 gbps single mode transceiver c-1x-1250(c)-tdfb(3)-ssc(2/3/4) 8 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 lumnds602-may1006 rev a.4 luminentoic.com ordering information c - 1x - 1250(c) - tdfb(3) - s sc txpower temperature and package -rohs ? 13 = wavelength 1310nm 15 = wavelength 1550nm ? communication protocol (1250 mbps) 1250 = pecl signal detection output 1250c = ttl signal detection output ? connector options ? tx power range blank = -9.5 to -3 dbm 2 = -5 to 0 dbm 3 = -3 to +2 dbm 4 = 0 to +5 dbm ? tdfb = +5v transceiver, dfb tdfb3= +3.3v transceier, dfb ? single mode ?ber ? temperature range and package blank = commercial temperature(0 to 70 oc) , 10.4 mm, black case a = industrial temperature(-40 to 85 oc) , 10.4 mm, black case b = industrial temperature(-40 to 85 oc) , 9.8 mm, blue case c = industrial temperature(-40 to 85 oc) , 9.8 mm, black case d = commercial temperature(0 to 70 oc) , 9.8 mm, black case e = commercial temperature(0 to 70 oc) , 9.8 mm, blue case available options: y c-13-1250(c)-tdfb-ssc(d/e) c-13-1250(c)-tdfb3-ssc (d/e) c-15-1250(c)-tdfb-ssc (d/e) c-15-1250(c)-tdfb3-ssc (d/e) c-13-1250(c)-tdfb-ssc2(a/b/c/d/e) c-13-1250(c)-tdfb3-ssc2(a/b/c/d/e) c-15-1250(c)-tdfb-ssc2(a/b/c/d/e) c-15-1250(c)-tdfb3-ssc2(a/b/c/d/e) c-13-1250(c)-tdfb-ssc4(a/b/c/d/e) c-13-1250(c)-tdfb3-ssc4(a/b/c/d/e) c-15-1250(c)-tdfb-ssc4(a/b/c/d/e) c-15-1250(c)-tdfb3-ssc4(a/b/c/d/e) c-13-1250(c)-tdfb-ssc3 (d/e) c-13-1250(c)-tdfb3-ssc3 (d/e) c-15-1250(c)-tdfb-ssc3 (d/e) c-15-1250(c)-tdfb3-ssc3 (d/e) part numbering de?nition: ? ordering information blank = rohs non-compliant product g5 = rohs 5/6-compliant product (lead exemption) c-13-1250(c)-tdfb-ssc (d/e) -g5 c-13-1250(c)-tdfb3-ssc (d/e) -g5 c-15-1250(c)-tdfb-ssc (d/e) -g5 c-15-1250(c)-tdfb3-ssc (d/e) -g5 c-13-1250(c)-tdfb-ssc2(a/b/c/d/e) -g5 c-13-1250(c)-tdfb3-ssc2(a/b/c/d/e) -g5 c-15-1250(c)-tdfb-ssc2(a/b/c/d/e) -g5 c-15-1250(c)-tdfb3-ssc2(a/b/c/d/e) -g5 c-13-1250(c)-tdfb-ssc4(a/b/c/d/e) -g5 c-13-1250(c)-tdfb3-ssc4(a/b/c/d/e) -g5 c-15-1250(c)-tdfb-ssc4(a/b/c/d/e) -g5 c-15-1250(c)-tdfb3-ssc4(a/b/c/d/e) -g5 c-13-1250(c)-tdfb-ssc3 (d/e) -g5 c-13-1250(c)-tdfb3-ssc3 (d/e) -g5 c-15-1250(c)-tdfb-ssc3 (d/e) -g5 c-15-1250(c)-tdfb3-ssc3 (d/e) -g5
1.25 gbps single mode transceiver 9 9 20550 nordhoff st. ? chatsworth, ca 91311 ? tel: 818.773.9044 ? fax: 818.576.9486 9f, no 81, shui lee rd. ? hsinchu, taiwan, r.o.c. ? tel: 886.3.5169222 ? fax: 886.3.5169213 lumnds601-may1006 rev a.4 luminentoic.com important notice! all information contained in this document is subject to change without notice, at luminentoic s sole and absolute discretion. luminentoic warrants performance of its products to current speci?cations only in accordance with the companys standard one-year warranty; however, speci?cations designated as preliminary are given to describe components only, and luminentoic expressly disclaims any and all warranties for said products, including express, implied, and statutory warran - ties, warranties of merchantability, ?tness for a particular purpose, and non-infringement of proprietary rights. please refer to the companys terms and conditions of sale for further warranty information. luminentoic assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. no license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and luminentoic makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. products described in this docu - ment are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. luminentoic customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify luminentoic for any damages resulting from such use or sale. the information contained in this document is provided on an as is basis. customer agrees that luminentoic is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. customer must contact luminentoic to obtain the latest version of this publication to verify , before placing any order, that the information contained herein is current. ? luminentoic, inc. 2003 all rights reserved handling precautions: this device is susceptible to damage as a result of electrostatic discharge (esd). a static free environment is highly recommended. follow guidelines according to proper esd procedures. laser safety: radiation emitted by laser devices can be dangerous to human eyes. avoid eye exposure to direct or indirect radiation. warnings: legal notes: c-1x-1250(c)-tdfb(3)-ssc(2/3/4)


▲Up To Search▲   

 
Price & Availability of C-13-1250C-TDFB3-SSC4E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X