Part Number Hot Search : 
AN7515SH C100RJ ISL8601 364112 EBJ02A N7615B FN1106 LT1716
Product Description
Full Text Search
 

To Download EDS11-166A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  enhance d communication module (cc-link) [pumcl] pumcl is a communication module, which connects module type temperature controller pum series with cc-link sys - tem. compatible with cc-link ver1.1 and 2.0, and designed for high-speed communication at the maximum speed of 10mbps. being able to up to 16 units (64 channel) of puma (control module), pumcl requires minimum wiring, less space, and saves labor for engineering. fe atures i. program-less connection to cc-link 1. cc-link ver1.1 / ver2.0 compatible high-speed communication at max.10mbps 2. access to all parameters of control module (puma/ pumb) via cc-link 3. high-speed data communication with connected control modules (puma/pumb) - quick data importing and setting data refection ii. user-friendly structure and functions 1. lateral connection : max.16 units (64 channels) + event input/output module 16 units = total 32 units simple wiring for power supply and communication 2. detachable structure: terminal block, main unit, and the base part easy wiring with detachable terminal blcok main units exchangeable without re-wiring sys tem specif ication 1. product type: multi-loop module type temperature controller 2. module type 1) analog module: total maximum 16 units a) control module (4 loop/unit) b) extended input/output module - analog input/output module (input/output 4 points/unit) - analog input module (input 4 points/unit) - analog output module (output 4 points/unit) 2) extended input/output (digital) module: maximum 16 units - event input/output module (input/output ; 8 points/unit) 3) enhanced communication module: 1 unit 3. connecting method: lateral connecting with connectors - for power supply and rs-485 communication, any one of connected modules is required to be connected. 4. no. of loop, input/output 1) control loop: max. 64 2) no.of input / output: di 128 points / do 128 points pum series multi-loop module type temperature controller pumcl data sheet EDS11-166A apr. 1, 2011 date enhanc e d communication modul e (cc-link) specif ication 1. general specifcation (1) power supply: 24v dc 10% (2) power consumption: max. 3.2 w (135 ma) [when 24v dc is applied] (3) insulation resistance: 20m w or more (500v dc) (4) withstand voltage: power supply ? loader communication 1000v ac 1 min. power supply ? sld/fg terminal, cc-link communication 500v ac 1 min. sld/fg terminal ? cc-link communica - tion 50v ac 1 min. (5) applied standards: ul, c-ul, rohs directive [pending for ul and c-ul] 2. cc-link communication module 2.1 cc-link communication (1) compliant version: cc-link ver.2.00 / 1.10 (2) station type: remote device (3) communication speed and distance speed 156kbps 625kbps 2.5mbps 5mbps 10mbps distance 1200m or less 900m or less 400m or less 200m or less 100m or less (4) occupation no. of channel/station: 4 stations/station no.setting; 1 to 61 (5) commnication data length no.of occupied sta - tions/extended cyclic remote input/output (rx/ry) remote registor (rwr/rww) control module (puma/b) no. of connectable units 4 stations occupied 1 128 bit 16 words 2 or 4 units 4 stations occupied 2 256 bit 32 words 4 or 8 units 4 stations occupied 4 512 bit 64 words 8 or 16 units (6) connecting cable: ver1.10 compatible cable for cc-link (7) connecting method: m3 screw terminal block (8) termination resistace: external (110 w , 1/2w)
pumcl 2 2.2 display, confguration (1) display: status display led (2 colors 2 points + 4 points) (2) display contents: run/fault, control module connection status (tx/rx), cc-link status (l.run, l.err, sd, rd) (3) setting device and set contents setting device set contents front rotary sw 2 cc-link station no. setting inside rotary sw 1 cc-link speed setting dip sw (6bit) 1 cc-link mode setting 3. power outage (1) impact of power outage: outage of 2ms or less ; no impact (2) operation after power outage: start from the frst step (cold start) (3) memory backup: nonvolatile memory (eeprom) no. of update ; 100,000 4. self diagnosis diagnosis method: program error monitoring by watch dog timer 5. structure (1) installation method: din rail mounting or mounting with m3 screws inside a cabinet (2) dimensions: 30 (w) 100 (h) 85 (d) mm (excluding terminal cover and projected part) (3) weight: approx. 200 g (4) extrenal terminal - cc-link communication: detachable terminal block (m3 screw 20 terminals) - power supply connection: terminal block on the base part (m3 screw 2 terminals) power is supplied via side connectors in case of lateral connecting. (max. 33 units) - loader communication port: 2.5 diameter mini-plug / jack [on the front of the module] (5) case material: polyphenylene oxide (fame retardant grade : ul94v-0 equiva - lent) (6) case color: case ; red terminal, base part ; black (7) protection - body: ip20 grade protection (ventilation slits on the top and the bot - tom of the body) - terminal: ip00 grade protection, terminal cover is available as an option 6. normal operating condition (1) ambient temperature*: -10 to 50c * ambient temperature is the tempera - ture underneath the controller inside the equpiment or the cabinet where the controller is installed. (2) ambient humidity: 90% rh or less (non condensing) (3) vibration: 10 to 70hz, 9.8m/s 2 (1g) or less 7. transporting, storage condition (packing con - dition) (1) storage temperature: -20 to 60c (2) ambient humidity: 90%rh or less (no condensing) (3) vibration: 10 to 70hz, 9.8m/s 2 (1g) or less (4) shock: 294m/s 2 (30g) or less 8. packing list temperature controller: 1unit instruction manual: 1 copy termination resistor of internal communication: 1 unit 9. loader software (1) distribution medium: free download from fuji electric sys - tems hp (http://www.fc-net.jp/eng/index. html) (2) recommended operating environment pc: dos/v (pc-at compatible) os: windows xp (operation confirmed in japanese / english) ram: 256m bytes or more free space on the hardware: 500m bytes or more display resolution: 1024 768 or over serial interface: rs-232c 1 port (without rs-232c, usb serial converter cable required) (3) connection with pum via loader interface on the front face of the module (special cable available from fuji is required) or via rs-485 cod e symbols [enhanced communication module] [accessories] d e scr i p t i o n 4 5 10 c l a b < m o d u l e t y p e > e n h a n c e d c o m m u n i c a ti o n m o d u l e < c o m m u n i c a t i o n f u n c t i o n > c c - l i n k co m m u n i ca t i o n < o p e r a t i o n m a n u a l > j a p a n e s e e n g l i s h digit 4 5 6 7 8 9 1 0 1 2 3 p u m y y digit 10 d e scr i p t i o n 6 7 8 a a a l 0 0 0 0 2 3 4 1 d i n r a i l m o u n t i n g e n d p l a t e s i d e co n n e t i n g t e r m i n a l co ve r ( r i g h t & l e f t 1 se t ) f r o n t f a ce scr e w t e r m i n a l co ve r l o a d e r co n n e ct i n g ca b l e ( r s - 2 3 2 c ) %jhju 4 5 6 7 8 1 2 3 p u m z * digit p o w e r s l d / f g t e r m i n a l ( c c - l i n k co n n e ct i n g t e r m i n a l ) l o a d e r co m m u n i ca t i o n p o r t c c - l i n k co m m u n i ca t i o n f u n ct i o n a l i n su l a t i o n ( 5 0 v a c ) f u n ct i o n a l i n su l a t i o n ( 1 0 0 0 v a c ) f u n ct i o n a l i n su l a t i o n ( 5 0 0 v a c ) [t able 1] i nsulation block diagram
3 outline dia gram (u nit : mm) please keep the distance of 30mm from this instrument to radiate. [50mm is recommended] front terminal cover (option) (10) 30 100 50 6.1 1.5 5 6 at mounting to the din rail (8) 85 din rail main unit (at attach/detach) (30) locking tab hole for screw mounting base part (main unit is detached) dimensions for screw mounting (30) 90.2 2-m3 (100) 88.50.2 (3) notice at the installation 30 or more 30 or more +0.2 +0.7 30 loader station no. 10 1 terminal screw m3 terminal block (at attach/detach) hole for screw mounting terminal screw m3
pumcl terminal connection dia gram loader 11 12 22 21 13 14 15 16 17 18 19 20 23 24 25 26 27 28 29 30 24 25 22 21 23 1 2 3 4 5 base part power + - 2 1 dont connect 3 4 5 1 2 3 gnd rx tx loader interface plug (rs-232c) 2.5 3-pole miniature plug 29 30 27 26 28 station no. 10 1 sld dg fg cc-link da db 11 14 15 13 12 19 20 17 18 16 dont connect terminating resistor of internal communi- cation dont connect dc24v printed in japan caution on safety *before using this product, be sure to read its instruction manual in advance. international sales div sales group gate city ohsaki, east t ower , 1 1-2, osaki 1-chome, shinagawa-ku, t okyo 141-0032, japan http://www .fujielectric.com phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www .fjielectric.com/products/instruments/ information in this catalog is subject to change without notice.


▲Up To Search▲   

 
Price & Availability of EDS11-166A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X