58 1-800-526-2324 ? www.us.tdk-lambda.com/lp/ disclaimer: us.tdk-lambda.com/lp/legal.htm hfe2500 series features u 1u rackmount containing up to 4 units u internal oring mosfet & current share u high ef? ciency u up to 9,500w in 1u rack 2500w 1u front end power supplies key market segments & applications (1) see installation manual for detailed speci? cations & test methods (2) derate linearly 1.3%/v from 100vac to 85vac input model input voltage range (2) vac 85 - 265vac, 47 - 63hz . see model selector for power derating input current (max) 100/230vac a 15 / 12a inrush current a <50a power factor correction - meets en61000-3-2, pf > 0.98 at full load temperature coef? cient %/c <0.02%/c overcurrent protection % 105 - 115% overvoltage protection (1) % 110% (tracking). cyc le ac to reset or utilize remote on/off overtemperature protection (1) - shutdown with aut omatic reset. warning signal provided hold-up time ms >10ms, 115/230vac input, 80% load ing leakage current ma < 0.75 / 1.5ma, 100 / 230vac, 60hz remote sense compensation - hfe2500-12: 0.25v / w ire, hfe2500-24: 0.5v / wire, hfe2500-48: 1v / wire indicators - ac ok: green led, dc ok / fail: gree n / red led remote on/off - unit on: 0 - 0.6v or short, off: 2 - 15v or open circuit parallel operation (1) - yes, single wire current share, 95% accuracy, up to 8 units ac fail signal - open collector, on when ac is wi thin 85 - 270vac dc good signal - open collector, on when output i s above 85 to 95% of setpoint (tracking) remote adjust (1) - by either external 0 - 5v sign al or 1k potentiometer i 2 c interface (1) - isolated from output, add suf? x /s, pmbus compatible auxiliary output - 11.2 - 12.5v, 0.5a, 240mv ripp le and noise operating temperature c -10 to +70c, derate 2%/ c from 50 to 60c, 2.5%/c from 60 to 70c storage temperature c -30 to +85c humidity (non condensing) %rh operating: 10 - 90% rh, storage: 10 - 95%rh cooling - two variable speed internal fans, air? ow exits across input/output connector withstand voltage - i/p to o/p 3kvac, i/p to gnd 2kvac, o/p to gnd: hfe2500-12, -24v 500vac, hfe2500 -48 1.5kvac isolation resistance m >100m at 25c & 70%rh, o utput to ground 500vdc vibration (basic transportation) - meets iec60068-2-64 shock (basic transportation) - meets iec60068-2-27 safety agency certi? cations - ul60950-1 (listed) , en60950-1, ce mark line dip - complies with semi f47 (200vac line on ly) conducted and radiated emi - en55022 & fcc part 1 5; conducted class b, radiated class a immunity - iec61000-4-2 (lv 2,3), -3 (lv 2), -4 ( lv 2), -5 (lv 3,4), -6 (lv 2), -8 (lv 4), -11 size (w x h x d) in power supply: 4.21 x 1.61 x 1 2.8, rack: 17.5 x 1.72 x 15.8 weight g power supply: 2100g, rack: 5000g warranty yrs three years speci? cations (hfe2500-48 model)
59 1-800-526-2324 ? www.us.tdk-lambda.com/lp/ revision a6: oct 2012 hfe2500 series output adjust max current max power max current max power model voltage range (1) (vin>170vac) (vin>170vac) (100 |