  2 /3/8 stage charging (note 4) universal ac input / full range built-in active pfc function pf>0.95 protection: reverse polarity / short circuit / over voltage / over temper ature charger for lead-acid batteries 3 color led loading indicator (depends on charging current) 3 years warranty built-in remote on-off control built-in temperature compensation function built-in fan speed control features : specification PB-600-12 pb-600-24 pb-600-48 model boost charge voltage float charge voltage output current battery type recommended battery capacity(amp hours) (note 3) output voltage range frequency range efficiency (typ.) power factor (typ.) input environment inrush current (typ.) leakage current over temperature safety standards harmonic current emi conduction & radiation safety & ems immunity emc (note 2) withstand voltage isolation resistance working temp. working humidity storage temp., humidity temp. coefficient vibration over voltage protection ac current (typ.) 14.4v 28.8v 57.6v 13.8v 40a open & sealed lead acid 135 ~ 400ah 27.6v 55.2v 21a 10.5a 70 ~ 210ah 35 ~ 105ah 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz 86% 0.95/230vac 0.98/115vac at full load 87% 89% 6.8a/115vac 3.4a/230vac 25a/115vac 50a/230vac <3.5ma / 240vac 16 ~ 18v 32 ~ 35v 64.5 ~ 69.5v protection type : shut down o/p voltage, re-power on to recover protection type : shut down o/p voltage, recovers automatically after t emperature goes down ul1012, tuv en60335-1, en60335-2-29 (except for 48v), en60950-1( 48v only) approved compliance to en55022 (cispr22) compliance to en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,8,11; env50204, en55024; li ght industry level, criteria a i/p-o/p:3kvac i/p-fg:1.8kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh -20 ~ +60 (refer to output load derating curve) 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.05%/ (0 ~ 50 ) 10 ~ 500hz, 2g 10min./1cycle, 60min. each along x, y, z axes mtbf 135.6khrs min. mil-hdbk-217f (25 ) 230*158*67mm(l*w*h) dimension others note packing 2.2kg; 6pcs/14.2kg/1.76cuft 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still mee ts emc directives. 3. this is mean well's suggested range. please consult your battery manuf acturer for their suggestions about maximum charging current limita tion. 4. please choose the "3 stage" selection when the charger is used to charge th e batteries and power the loads in the same time. pb-600 series 600w single output battery charger function remote control leakage current from battery (typ.) fast charge output ok charging ok temperature sense open: normal work short: stop charging 1ma 2 / 3 / 8 stage selectable relay contact (ry13) relay contact (ry15) by ntc file name:pb-600-spec 2011-04-20 ..
mechanical specification case no.805c unit:mm charging curve charge current charge current constant current constant current stage 1 stage 1 stage 2 stage 2 stage 3 constant voltage constant voltage float start start 2 stage 3 stage charge voltage charge voltage 100% 100% 10% 10% boost boost float v vv orange orange green green color of led color of led pb-600 series 600w single output battery charger file name:pb-600-spec 2011-04-20 pin no. pin no. 5,6 7 9 10 3,4 ry13 : battery bank ok ntc / gnd : temperature sense ry15 : charging ok rc+ / rc-: remote on/off 1,2 8 assignment assignment ry15 gnd nc ry13 mating housing terminal or equivalent or equivalent control pin no. assignment(cn100) : hrs df11-10dp-2ds or equivale nt hrs df11-10ds hrs df11-**sc rc- rc+ ntc(5k ) air flow direction ac input inlet on off switch on/off 42.5 145 9 7 230 stage 8/3/2 power 67 33 158 48 67 24.1 10 1 2 3 4 5 6 7 8 9
derating curve static characteristics load (%) input voltage (vac) 60hz 90 95 100 115 264 90 100 80 70 60 50 40 ambient temperature ( ) load (%) 20 40 60 80 100 -20 0 10 20 30 40 50 60 70 ta=25 (horizontal) pb-600 series 600w single output battery charger file name:pb-600-spec 2011-04-20 block diagram control control detection detection switching power active inrush current limiting rectifier & pfc pfc control aux power mcu fan otp pwm remote bank ok charging ok reverse current filter & rectifier +v 2/8 stage select rc ry13 ry15 i/p filter emi pfc : 95khz pwm fosc : 60khz charge current stage 1 stage 2 stage 3 stage 4 stage 5 stage 6 stage 7 stage 8 charge voltage 8 stage pulse soft start constant current constant voltage analysis recond float maintain orange green color of led
between rc+(pin10) and rc-(pin9) sw open sw short charging on off the charger can be turned on/off by using the "remote control" function. sw pb-600 series 600w single output battery charger file name:pb-600-spec 2011-04-20 powerpower power stage 8/3/2 stage 8/3/2stage 8/3/2 1010 10 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 9 10 cn100 ry13 nc ry15 gnd rc- ry13 nc ry15 rth rc+ 1 2 function manual 1.remote control ++ + battery battery battery -- - switch right middle left charging mode 2 stage charging 3 stage charging 8 stage charging (1)the charger features user selectable 2,3, or 8 stage charging. (2)please choose the "3 stage" selection when the charger the charging profile is selected by moving the slide switch is used to charge the batteries and power the loads in the same time. on the back panel. 2. 2,3, or 8 stage charging select charger normal work between pin5 and pin6(ry15) on (short) off (open) 3.charger ok relay(ry15) 99 10 10 cn100 cn100 ry13 ry13 nc nc ry15 ry15 gnd gnd rc- rc- ry13 ry13 nc nc ry15 ry15 ry15 rth rth rc+ rc+ 11 22 failure or the protection function is activating function description of cn100 the function of leds pin no. battery function description color of led 1,2 fail charging battery full 5,6 7,8 9,10 ry13 relay contact rating(max.) : 30v/1a resistive. ; "short" when the batt ery is full, relay contact rating(max.) : 30v/1a resistive. ; "short" when the unit i s working properly, temperature sensor comes along with the charger can be connected to the uni t to allow turn the output on and off by electrical or dry contact between pin 10 (rc+) and pi n 9(rc-) "open" when the battery is still charging "open" when the unit stop charging temperature compensation of the charging voltage open : normal work , short : stop charging red orange green ry15 gnd / rth rc- / rc+
bank 1.bank ok (ry13) between pin1 and pin2(ry13) color of led on (short) green off (open) orange 4.output ok (ry13) 9 10 cn100 ry13 nc ry15 gnd rc- ry13 nc ry13 ry15 rth rc+ 1 2 pb-600 series 600w single output battery charger file name:pb-600-spec 2011-04-20 power 10 1 2 3 4 5 6 7 8 9 power 10 1 2 3 4 5 6 7 8 9 + battery - + battery - temperature sensor comes along with the charger can 5.temperature compensation be connected to the unit to allow temperature compensation of the charging voltage. if the sensor is not used, the charger still works normally. cn100 ntc ry13 nc ry15 gnd rc- ry13 nc ry15 rth rc+ 1 2 9 10 battery full charging the temperature sensor can either be attached to the battery or placed in its surrounding environment. stage 8/3/2stage 8/3/2


▲Up To Search▲   

 
Price & Availability of PB-600-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X