![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
ds250-5 nov ?06 ? 2006 reg no 277 4001, england. page 1 gsm t elemetry s ystem 250 ? remote control from a mobile phone ? standalone dual band gsm telemetry controller. ? 2 digital inputs (volt free) ? 2 relay outputs rated at 240 volts 12 amps. ? automatically sends sms message when input activated to up to 5 mobiles per input. ? outputs controlled by sms text message. ? request status via sms. ? accepts all major sim cards. ? ip65 rated enclosure. ? easy to install and configure (no pc required). ? dual band modem gsm / gprs (telit) applications ? remote control by gsm mobile phone. ? remote maintenance, warnings / alarms. ? irrigation systems. ? remote system monitoring. ? plant maintenance. ? security systems ? alert / panic caller ordering information part no description 250R1 gsm telemetry system with integrated gps module psu12v1ain power supply, 110-230vac (iec input), o/p 12vdc, 900ma
ds250-5 nov ?06 ? 2006 reg no 277 4001, england. page 2 gsm t elemetry s ystem 250 user manual 1. definitions....................................................................................2 2. sim card .......................................................................................3 3. input and output circuits ............................................................3 4. output relays ..............................................................................4 5. power up ......................................................................................4 6. power loss ..................................................................................4 7. user set-up of 250 ......................................................................4 8. user set-up commands .............................................................5 9. control co mmands .....................................................................7 10. messages generated by the unit.............................................9 11. technical specifications .......................................................10 1. definitions the following definitions are used throughout this docum ent and generally in connection with the control unit. message an sms (?text?) message sent fr om one mobile station to another. ~ denotes a ?space? in the format of a message. alphanumeric . characters in the range a to z (upper and lower case), numbers in the range 0 ? 9. mobile . a mobile telephone that is used to send and receive sms messages. ds250-5 nov ?06 ? 2006 reg no 277 4001, england. page 3 gsm t elemetry s ystem 250 2. sim card the unit will accept sim cards of most ty pes subject to the following restrictions. 1. only 3 volt sim cards will be correctly read and older 5 volt types will be ignored. 2. some types of pay-as-you-go sim cards may require regular call activity (once every six months) to remain registered. 3. sim cards that have been pr otected by means of a pin (in a mobile phone) will not operate in the unit. 4. incoming voice calls to the sim card s hould be barred before it is used in the gsm 250 unit to avoid any error messages being sent back to the user. this can be achieved by calling the service provider. 5. the message memory of the sim card shoul d be clear before it is fitted to the 250 unit. the sim card should be inserted into the side of the module (marked telit). the pcb may need to be removed from the enclosure in order to insert the sim card. 3. input and output circuits the two inputs are provided via screw terminals g nd/in1 and gnd/in2 terminals. these two volt-free digital inputs are designed to be actuated by contac t ?switch? closures across the input pins. gnd in1 in2 users switch contacts gnd ds250-5 nov ?06 ? 2006 reg no 277 4001, england. page 4 gsm t elemetry s ystem 250 4. output relays two relay outputs are provided, which when acti vated provide a ?switch? output as below. 5. power up the 250 unit can be powered from 12 or 24vdc, a mains power supply is also available. connecting to the 3 pin terminal block provides the 250 with power. on power up the pwr led will illuminate steady green. the gsm engine takes several seconds to warm-up. the gsm led may flash when the gsm engine is active. the gsm will come on after several seconds and should st art to blink, indicating that the gsm modem has registered with the network and that the unit is r eady to accept user commands. the stat led blinks whenever there is gsm activity, i.e. t he unit is sending or receiving a text. 6. power loss in the event of power loss to the 250 the unit will maintain the user configured data entered during the user set-up sequence, as this inform ation is stored in non-volatile me mory. however the status of the relays will be lost. 7. user set-up of 250 prior to usage, it is necessary to program the 250 unit with the following parameters. (some are optional) note that the user password is case sensitive but the commands are not case sensitive and will be converted into upper case before the unit handles them. this means that any user command responses, which echo the original command will do so in upper case. all commands are sent as text messages from a mobile phone. com no nc relay connections when transmitter not operating com no nc relay connections when transmitter operating ch1 ch2 ds250-5 nov ?06 ? 2006 reg no 277 4001, england. page 5 gsm t elemetry s ystem 250 8. user set-up commands please note: ~ denotes a ?space? in the format of a message command description command syntax example unit password (upw) the string ds250-5 nov ?06 ? 2006 reg no 277 4001, england. page 6 gsm t elemetry s ystem 250 user setup commands cont.. please note: ~ denotes a ?space? in the format of a message command description command syntax example power failure number-to-text (pnum) (optional) this command is used to identify the mobile number which is to be text if power has be removed from the 250. pnum can store up to 5 mobile numbers. ds250-5 nov ?06 ? 2006 reg no 277 4001, england. page 7 gsm t elemetry s ystem 250 9. control commands please note: ~ denotes a ?space? in the format of a message command description command syntax example activate and deactivate outputs (out) this command is used to turn a relay output on or off. ds250-5 nov ?06 ? 2006 reg no 277 4001, england. page 8 gsm t elemetry s ystem 250 control commands cont? please note: ~ denotes a ?space? in the format of a message retrieve saved numbers to text for inumn this command requests the mobile phone numbers for input 1 or 2 (inumn) to be returned to this caller. ds250-5 nov ?06 ? 2006 reg no 277 4001, england. page 9 gsm t elemetry s ystem 250 10. messages generated by the unit please note: ~ denotes a ?space? in the format of a message message description message syntax example change of status of inputs (in) this message reports a change of input state to the designated mobile number (set using the inum command). a message is sent with the following format. a change of input will only be ?valid? after 5msecs where the 250 unit is processing an sms messages then the response time could be up to 250ms. ds250-5 nov ?06 ? 2006 reg no 277 4001, england. page 10 gsm t elemetry s ystem 250 11. technical specifications storage temperature: -10 to +70 o celsius. operating temperature: 0 to +55 o celsius. enclosure dimensions: 145 x 90 x 45mm pcb dimensions: 124 x 78mm electrical characteristics min typical max dimension notes supply voltage for 12vdc 11 12.0 14 v supply voltage for 24vdc 23 24.0 26.0 v supply current for 250: idle operating 35 200 44 370 100 1000 ma ma 1 2 mains rated relay rating (230vac) 5 12 a 3 notes 1. refers to maximum supply current required with all components idle. 2. refers to peak supply current required with all components operating. in practice internal reservoir capacitance limits the instantaneous peak current to less than 500 ma. 3. the relay contacts in this unit are for functional switching only and must not be used for isolation purposes. for more information or general enquiries, please call; r f solutions ltd., unit 21, cliffe industrial estate, lewes, e. sussex. bn8 6jl. england. email : sales@rfsolutions.co.uk http://www.rfsolutions.co.uk tel: +44 (0)1273 898 000 fax: +44 (0)1273 480 661 rf solutions is a member of the low power radio association. information contained in this document is believed to be accurate , however no representation or warranty is given and no liabi lity is assumed by r.f. solutions ltd. with respect to the accuracy of such information. use of r.f.solutions as critical components in life support systems is not authorised except with express wri tten approval from r.f.solutions ltd. |
Price & Availability of 250R1
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |