  data sheet pnc1 compact controller s (fixed function type) is a compact single-loop controller using a microprocessor. it accepts uniform signals, and signals from a thermo- couple and resistance bulbs as input, and includes sufficient control and computation functions which permit composition of a flexible system for pid control, square-root extraction, non-linear control, etc. 1. pid auto turing function optimum pid parameter can be obtained for processing. 2. high reliability led's (red and green) are used for the bar graph indicator and for parameter indication (red). a non-volatile memory retains the control and computation parameters even if power should be interrupted. 3. all operations are performed from the front of the panel operations such as parameter setting, auto/manual changeover are performed from the front of the panel. 4. transmission function incorporation of transmission function permits setting of concentrated monitoring data at the host system. fc series compact controller s (step output type) features functional diagram personal computer to other controllers bar graph indicator communication terminal linearize a.m 4 to 20ma, thermocouple/ resistance bulb conversion external input terminal d/a converter opening/resistance conversion valve position input (w 0 ) process value input (pv) external set point input (cas) pulse input (pi) manual mode command (smv) pv tracking (di1) remote acknowledge signal (di3) : option a/d converter internal input terminal filter r r m mode non-linear pulse width conversion m mode r mode fault l or scc mode square-root extraction p i d sh sl h mv l m r.a alarm flt lamp h lamp l lamp control output (pulse width) (po) valve position output (voltage) (ao1) compensated pv signal output (kpv) set point transmit signal output (sv) manual mode output (m) local mode output (do1) remote request (r-req) fault output (flt) high alarm output (h) low alarm output (l) external output terminal date EDS11-101E jan. 27, 1999
pnc1 2 (2) operation mode indication indication method: led (red and green) red: m, scc green: a, r (3) numerical indication, setting indication method: led (red), name in 3 digits + number in 5 digits (negative sign included) indication contents: process variable (engineering unit), set point (engineering unit), alarm high/low values, pid parameters, etc. indication contents are select by using f/s, , , keys setting method: by using of f/s, , , , st keys on front panel (4) sv setting function fixed value setting method: by using , pushbuttons on front panel setting speed, about 40 sec/fs remote setting method: by external set point signal (voltage or pulse width input) (5) mv operating function manual operating method: by using , buttons on front of the panel (6) operation mode changeover by using r/a/m button on front panel 2. input signal (1) pv input signal: one point select from the following inputs. input resistance, 1m ? or more allow. error, 0.2%/fs 24v dc power is supplied to transmitter with ac power used. allow. error, 0.2%/fs 10mv dc span, or more self-contained basic contact compensating function allow. error 0.5%/fs 50 c span or more allow. error 0.5%f/s (1) control output signal: 1 set (3) digital output signal: 6 points 4. indication, setting and operating functions (1) bar graph indication mv indicator led (red) 51 + 2 0 to 100%, linear 2%/fs 50mm indication system indication indication segment indication range indication resolution scale length indication mode pv indicator led (red) 101 + 2 0 to 100% linear 1 %/fs 100mm 1 to 5v dc 4 to 20ma dc type j:0 to 600 c k:0 to 1200 c e:0 to 800 c r:0 to 1600 c jpt100/pt100 ?0 to 500 c voltage input signal current input signal thermocou- ple input resistance bulb input i + i 0 i 3. output signal open-collector output (photo-coupler insulation) po + po pulse width fault output manual mode output high alarm output low alarm output local mode output remote request signal flt m h l do1 do2 open-collector output (photo- coupler insula- tion) output rating, 30v x 0.1a dc, max. 1. control functions pid control: proportional band (p); 1.0 to 3276.7% integration time (i); 0.1 to 3276.7 sec derivative time (d); 0.0 to 900.0 sec pid auto tuning function additional function: segmented line approximation; 15 seg- mented lines square-root extraction; with low input cut function filter; filter time constant 0.0 to 900.0 sec non-linear control output change rate limiter; 0.0 to 100.0% alarm functions: select any 1 of 3 types at left front panel led (h, l) on, digital output (h, l) "on" pv high/low limit alarm pv change rate alarm dv high/low limit alarm control cycle: 0.1 sec (2) analog input signal: 1 point (3) digital input signal: 3 points 1 to 5v dc input resistance, 1m ? or more allow. error 0.2%/fs cas external set point manual mode command pv tracking command remote acknouwledge signal smv di1 di3 contact in- put (photo- coupler insulation) on/0v, off/24v (input current, approx. 11ma/24v dc) (4) pulse width or pulse number input signal: any 1 set on/0v, off/24v (input current, approx. 11ma/24v dc) on/0v, off/24v (approx. 11ma/24v dc), max. input frequency 500hz contact input (photo-coupler insulation) pulse width input signal pulse number input signal pi + , pi (5) valve position input w 0 w + w 0 w voltage input signal resistance input signal 1 to 5v dc 50 to 1000 ? width (note 2) input resistance, 1m ? or more allow. error, 0.5%/fs 3-wire system potentiometer allow. error, 0.5%/fs notes: (1) fs: full scale (2) basic value is 10 to 100 to 10 ? . others should be specified. output rating, 30v x 0.1a dc max. (2) analog output signal: 3 points compensated pv value signal set point transmission signal value position (voltage) kpv sv ao1 1 to 5v dc output resistance, 1 ? or less allow. error, 0.2%/fs sv indicator led (green) 101 + 2 0 to 100% linear 1 %/fs 100mm 0 to 100% bar graph indication, 0 to 100% reverse bar graph indication, dot indication, ?0 to +50% deviation indication r a changeover balanceless bumpless a r changeover voltage signal balance bumpless pulse width input balanceless bumpless a or r m changeover balanceless bumpless specifications
3 transmission speed: 19.2 kbps no. of units to be connected: 15 max. transmission distance: 500m max. transmission form: multi-drop code format: 12 bit binary 2) rs-422: universal interface transmission speed: 2400, 4800, 9600, 19200bps, select- able no. of units connectable: 31 max. code format: stop bit .... 1 or 2 bit parity bit ... even, odd or none 8. other functions data protection function by use of pass code 9. operating conditions power supply: select from the following 3 types 24v dc (20 to 30v) 100v ac (85 to 132v/47 to 63hz ac) 200v ac (187 to 264v/47 to 63hz ac) power consumption: approx. 12w (dc) approx. 20va (ac) dielectric strength: 1500v ac, 1 min. insulation resistance: 500v dc, 100m ? or more ambient temperature: 0 to 50 c ambient humidity: 90% rh or less enclosure: steel case enclosure class: front ip65 (iec 529) name plate: 100 (h) x 70 (w), white acryl dimensions: 144 (h) x 72 (w) x 391 (d) mm, iec (din) standards mass {weight}: approx. 2.9kg mounting method: flush on indoor panel, vertical mounting is standard practice. mounting on tilted surface possible (angle ) finish color: munsell n1.5 for the both of front and case. range of delivery: controller and mounting bracket items prepared separately: transmission cable (type pnz) 5. power failure processing functions power failure detection: control stoppage at power failure detec- tion during power failure: operating parameters backed up by ca- pacitor when power faulure occurs wthin 5 minutes initial set point and manipulated output values, pid parameters, etc. are stored in nonvolatile memory (lasts for 10 years or longer at ambient temperature of 50 c or less). power failure recovery time: initial or continuous start set for power failure within 5 minutes. recovery from power failure lasting longer than 5 minutes is done by initial. * operation mode at initial set. m: manual mode a: auto mode r: remote mode scc: scc mode 6. self-diagnosis function computation/control circuit abnormality: flt indicator lights, flt contact output turns "on", and computation and control stop. manipulated output can be controlled manually at flt (soft manual). input/output signal abnormality, manipulated output disconnection: flt indicator lights, control stops and manipulated output is held. computation processing and output processing other than for manipulated output continue. fault contents indication: cause of fault is indicated numerically on numerical indicator on front of the panel. 7. transmission functions (1) transmission items supervisory items: from pnc to host process variable, set point, manipulated output, deviation, operation mode, alarm information, pid parameters, various limiter values, constants, segmented line, analog input/output, digital input/output, etc. setting operation items: from host to pnc set point, manipulated output, operation mode, pid parameters, various limiter values, constants, segmented line, etc. (2) transmission setting inhibit: parameter setting enable/inhibit can be designated by transmission from the host. designation is made by using f/s, , , , st keys on the front of the panel. (3) transmission interface: cc data line or rs422 interface select 1) cc data line: connected with transmission controller (pmn) interface: pmn and pna; cc data line (pmn and host rs-232c) =0 to 90
pnc1 4 notes: (1) standard resistance is 10 to 100 to 10 ? . others should be specified. (2) symbols of resistance bulbs are as follows. jpt100 ..... jis c 1604-1981 pt100 ....... iec pub751-1983 (jpt/pt changeover is possible with front key.) terminal cover terminal panel thickness 8mm or less 140 16 support bracket 200min. when mounting one unit when mounting "n" units 355 36 mounting bracket 144 72 panel cutout 250min. (72.2n 4) +1 0 138 +1 0 no. of units n 2 200min. 138 +1 0 68 +0.7 0 = > code symbols outline diagram (unit:mm) 12345678 9101112 pnc1 a b c d e f g w a b 1 2 3 a 0 1 2 r c a 5- description pid auto turing function provided process variable input signal 1 to 5v dc 4 to 20ma dc j thermocouple k thermocouple e thermocouple r thermocouple resistance bulb, jpt100, 3-wire system, 50 c span or more resistance bulb, pt100, 3-wire system, 50 c span or more 10mv dc span or more, with basic junction compensat- ing function setting method a-m type r-a-m type power supply 24v dc (20 to 30v dc) 100v ac (85 to 132v/47 to 63hz ac) 200v ac (187 to 264v/47 to 63hz ac) valve position input voltage input (1 to 5v dc) resistance input (50 to 1000 ? span) (note 1) transmission function rs-422 cc data line (communication controller required)
5 block terminals (m4 screws) process value input terminal connections ao (compensated process value signal output) ao (set point transmit signal) ao (valve position output signal) w 0 (valve position input) ai, ao common bus po (operation output) do (high alarm output) do (low alarm output) power supply (24v dc, ac power) di, do 24v power kpv sv ao 1 w 0 sc po + po h l pc* pcd g note: * symbols for ac power supply are vpo, pco. output is 24v dc (0.1a max.) approx. 51 52 53 54 55 56 57 58 59 60 61 62 ground 71 72 73 74 75 76 77 78 79 80 81 82 + + cas ai1 ai2 w + w sc do 2 di 3 di 2 di 1 vp* vpd ai (external set point) unused w + (valve position input) w (valve position input) ai, ao common bus do (remote request) di (remote acknowledge) unused di pv tracking command power supply (24v dc, ac power) di, do 24v power ? ? ? ? ? ? 1 to 5v dc the 5th digit of code symbols: a 4 to 20ma dc the 5th digit of code symbols: b thermocouple the 5th digit of code symbols: c,d,e,f resistance bulb the 5th digit of code symbols: g,w 4 to 20ma dc power supply the 5th digit of code symbols: b 11 + 31 12 11 12 11 12 11 12 11 12 31 31 60 pc 31 31 + + + + + + + connection diagram i + (pv) ai (process value input) do (manual mode) do (local mode) do (manual mode command) i (sc) m do 1 smv ac 13 12 11 14 15 33 32 31 34 35 pi pi+ i 0 flt ac 16 pi (pulse width input or pulse number input) do (flt output) power supply (ac)
pnc1 transmission connector 6 7 8 9 1 2 3 4 5 sig gnd (vst) shld inh txd+ txd rxd+ green red yellow brown black white rxd 6 7 8 9 1 2 3 4 5 sig gnd (vst) shld inh txd+ txd rxd+ rxd 6 7 8 9 1 2 3 4 5 sig gnd (vst) shld inh txd+ txd rxd+ green red yellow brown black host master controller white rxd 6 7 8 9 1 2 3 4 5 sig gnd (vst) shld inh txd+ txd rxd+ terminating resister rxd pnc1 pnc1 pnc1 pnc1 host transmission cable termination resistor end controller 1st controller information in this catalog is subject to change without notice. printed in japan head office 6-17, sanbancho, chiyoda-ku, tokyo 102-0075, japan http://www.fesys.co.jp/eng sales div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http: //www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDS11-101E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X