power entry modules with line filter kmf www.schurter.com/pg0 6 emc products iec appliance inlet c14 with filter, fuseholder 1- or 2-pole, line switch 2-pole kmf: with shield and line filter plug removal necessary for fuse replacement c14 70 c description - panel mount: snap-in version from front side - 4 functions: appliance inlet protection class i, line switch 2-pole, fuseholder for fuse-links 5 x 20 mm 1- or 2-pole, line filter in standard and medical version - quick connect terminals 4.8 x 0.8 mm approvals - vde certificate number: 126123 - ul file number: e72928 characteristics - ultra-compact design. small dimensions in front of and behind the pa - nel - all single elements are already wired - for added safety "extra-safe" fuse drawers are available fuse drawer meets requirements of medical standard iec/en 60601-1 the fuse drawer can only be opened with the aid of a tool the fuseholder is accessible from the equipment front - innovative emc-shielding with flexible steel segments for an excellent contact - qualified for use in equipment according iec/en 60950 other versions on request - fuse drawer 1-pole, plus spare fuse case - fuse drawer 2-pole, with shorting bar - other rocker marking references alternative: version without line filter k m alternative: version for screw mounting dd1 2 weblinks pd f , general product informatio n , approval s , roh s , china-roh s , mating connector s , e-stor e , schurter-stock-chec k , distributor- stock-chec k , accessorie s , wire harnes s technical data ratings iec 1 - 10 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 1 - 10 a @ ta 40 c / 125 vac; 60 hz leakage current standard < 0.5 ma (250 v / 60 hz) medical < 5 a (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 terminal quick connect terminals 4.8 x 0.8 mm panel thickness s snap-in: 1/1.5/2/2.5 mm (all steps with one variant) material: housing thermoplastic, black, ul 94v-0 appliance-inlet/-outlet c14 acc. to iec/en 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class 1 fuseholder 1 or 2 pole, shocksafe category pc2 acc. to iec 60127-6, for fuse-links 5 x 20 mm rated power acceptance @ ta 23 c 5 x 20: 2 w (1 pole)/ 1.4 w (2-pole) per pole power acceptance @ ta > 23c admissible power acceptance at hig - her ambient temperature see derating curves line switch rocker switch 2-pole, non-illuminated, acc. to iec 61058-1 technical detail s line filter standard and medical version, iec 60939, iec 60601-1, ul 1283, ul 544, en 133 200, csa c22.2 no. 8 technical detail s mtbf > 1'800'000 h acc. to mil-hb-217 f
power entry modules with line filter kmf www.schurter.com/pg0 6 emc products dimensions 42.9 mm r1.5 30.5 50 32 10.7 l 46.8 27.8 30.4 25.7 40.4 2.5 s 0.05 max. r 0.3 47.8 +0.10 -0.05 +0.10 -0.05 0 28.8 n technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 11 47 2.2 - 2 standard version 2 x 4 47 2.2 - 4 standard version 2 x 1.6 47 2.2 - 6 standard version 2 x 0.7 47 2.2 - 10 standard version 2 x 0.4 47 2.2 - 1 medical version (m5) 2 x 11 47 - 1 2 medical version (m5) 2 x 4 47 - 1 4 medical version (m5) 2 x 1.6 47 - 1 6 medical version (m5) 2 x 0.7 47 - 1 10 medical version (m5) 2 x 0.4 47 - 1 diagrams standard version 1) line 2) load medical version 1) line 2) load derating curves 1-pole admissible power ac - ceptance in watt 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n 2.0 1.5 1.0 0.5 0.0 ambient air temperature ta c 2-pole admissible power ac - ceptance in watt per pole 0 2 0 4 0 6 0 8 0 100 0.2 0.0 i = < < i n i = 0.7 i n i = 1.0 i n 1.4 0.6 0.4 1.0 0.8 1.2 ambient air temperature ta c
power entry modules with line filter kmf www.schurter.com/pg0 6 emc products attenuation loss - - - - differential mode _____ common mode standard version 1 a 2 a 4 a 6 a 10 a medical version (m5) 1 a 2 a 4 a 6 a 10 a variants fuse drawer must be ordered separately (see accessories). rated current [a] filter-type fuseholder line switch order number 1 standard version 1-pole 2-pole kmf1.1211.11 2 standard version 1-pole 2-pole kmf1.1221.11 4 standard version 1-pole 2-pole kmf1.1241.11 6 standard version 1-pole 2-pole kmf1.1261.11 10 standard version 1-pole 2-pole kmf1.1291.11 1 standard version 2-pole 2-pole kmf1.1111.11 2 standard version 2-pole 2-pole kmf1.1121.11 4 standard version 2-pole 2-pole kmf1.1141.11 6 standard version 2-pole 2-pole kmf1.1161.11 10 standard version 2-pole 2-pole kmf1.1191.11 1 medical version (m5) 1-pole 2-pole kmf1.1213.11 2 medical version (m5) 1-pole 2-pole kmf1.1223.11 4 medical version (m5) 1-pole 2-pole kmf1.1243.11 6 medical version (m5) 1-pole 2-pole kmf1.1263.11 10 medical version (m5) 1-pole 2-pole kmf1.1293.11 1 medical version (m5) 2-pole 2-pole kmf1.1113.11 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 standard version 2 x 11 47 2.2 - 2 standard version 2 x 4 47 2.2 - 4 standard version 2 x 1.6 47 2.2 - 6 standard version 2 x 0.7 47 2.2 - 10 standard version 2 x 0.4 47 2.2 - 1 medical version (m5) 2 x 11 47 - 1 2 medical version (m5) 2 x 4 47 - 1 4 medical version (m5) 2 x 1.6 47 - 1 6 medical version (m5) 2 x 0.7 47 - 1 10 medical version (m5) 2 x 0.4 47 - 1
power entry modules with line filter kmf www.schurter.com/pg0 6 emc products rated current [a] filter-type fuseholder line switch order number 2 medical version (m5) 2-pole 2-pole kmf1.1123.11 4 medical version (m5) 2-pole 2-pole kmf1.1143.11 6 medical version (m5) 2-pole 2-pole kmf1.1163.11 10 medical version (m5) 2-pole 2-pole kmf1.1193.11 packaging unit 20 pcs required accessor y description fusedrawer 2 fusedrawer with and without voltage selector insert fingergrip, 2-pole 4301.1401 extra-safe, 2-pole 4301.1403 fingergrip, 1-pole 4301.1405 extra-safe, 1-pole 4301.1407 ... accessorie s assorted cover s rear cover 0859.0076 wire harnes s wire harness for schurter products cord retaining kit s cord retaining strain relief flat head, a 4700.0001 mating outlets/connector s category / description appliance outletoverview complet e iec appliance outlet f, screw-on mounting, front side, solder terminal 478 7 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 478 8 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 509 1 iec appliance outlet f or h, screw-on mounting, front side, solder or quick-connect terminal 509 2 appliance outletfurther types tokm f
power entry modules with line filter kmf www.schurter.com/pg0 6 emc products connectoroverview complet e iec connector c15, rewireable, straight 010 1 iec connector c15a, rewireable, straight 010 2 iec connector c15a, rewireable, straight 0102- g iec connector c15a, rewireable, angled 011 2 iec connector c13, rewireable, angled 401 2 connectorfurther types tokm f ... power cordoverview complet e power cord with iec connector c13, angled 031 1 power cord with iec connector c13, angled 301 1 power cord with iec connector c13, angled 301 2 power cord with iec connector c13, angled 301 3 power cord with iec connector c13 302 0 power cordfurther types tokm f ... the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.
|