maxi m u m ratings t ypical ope r ati on the eimac 4cx25,000c is a ceramic/metal power tetrode intended for use as a vhf power amplifer. it features a type of internal mechanical structure which results in high rf operating effciency. low rf losses in this structure permit operation at full ratings to 110 mhz. the 4cx25,000c is recommended for use in in- band-on-channel (iboc) fm broadcast service with combined digital and analog components. the anode is rated for 25 kilowatts of dissipation with forced-air cooling and incorporates a com - pact, highly effcient cooler of new design. r a d ial b ea m p ow e r cpi | 4 c w50,000j for information on this and other cpi products, visit our website at: www.cpii.com , or contact: cpi mpp, eimac operation, 607 hansen way, palo alto, ca 94303 telephone : 1(800) 414-8823. fax : (650) 592-9988 | email : powergrid@cpii.com july 2011 the values listed above represent specifed limits for the product and are subject to change. the data should be used for basic information only. formal, controlled specifcations may be obtained from cpi for use in equipment design. c ha r acte r istics 1 electrical filament: thoriated tungsten mesh voltage 10.0 0.5 v current at 10.0 volts 140 a amplifcation factor, average, grid to screen 6.7 direct interelectrode capacitances (grounded cathode) 2 cin 195 pf cout 22.7 pf cgp 0.6 pf direct interelectrode capacitances (grounded grid and screen) 2 cin 87.4 pf cout 23.1 pf c pk 0.08 pf maximum frequency for full ratings (cw) 110 mhz mechanical: maximum overall dimensions: length 10.1 in; 256.54 mm diameter 8.9 in; 226.0 mm net weight 26.5 lbs. 58.3 kg operating position vertical, base up or down maximum operating temperature: ceramic/metal seals 250 c anode core 250 c cooling forced air base special, coaxial recommended socket for vhf eimac sk-360 recommended socket for dc to hf eimac sk-320 cpi | r a d ial b ea m p ow e r tet rod e 4 cx 25,000 c tet rod e 4 cx 25,000 c 1 characteristics and operating values are based upon performance tests. 2 in shielded fxture. 1
absolute maximum ratings: dc anode voltage 13.0 kilovolts dc screen voltage 2.0 kilovolts dc grid voltage -1.5 kilovolts dc anode current 5.0 amperes anode dissipation 20 kilowatts screen dissipation 450 watts grid dissipation 200 watts note: typical operation data are obtained by actual measurement or by calculation from published characteristic curves. to obtain the anode current shown at the specifed bias, screen and anode voltages, adjustment of rf grid voltage is assumed. if this procedure is followed, there will be little variation in output power when the tube is replaced, even though there may be some variation in grid and screen currents. the grid and screen currents which occur when the desired anode current is obtained are incidental and vary from tube to tube. these current variations cause no performance degradation providing the circuit maintains the correct voltage in the presence of the current variations. r a d i o fr e q uency p ow e r a m pli f ie r cath od e g ro un de d fm continuous service g rid driven c lass c absolute maximum ratings: dc anode voltage 13.0 kilovolts dc screen voltage 2.0 kilovolts dc grid voltage -1.5 kilovolts dc anode current 5.0 amperes anode dissipation 20 kilowatts screen dissipation 450 watts grid dissipation 200 watts r a d i o fr e q uency p ow e r a m pli f ie r g r i d s g ro un d e d for rf fm continuous service c athode driven c lass b typical o pe r ati o n (measured data at 107.1 m h z): anode voltage 9.0 11.5 12.0 kvdc screen voltage 800 650 1000 vdc grid voltage -300 -400 -500 vdc anode current 4.15 3.75 3.54 adc screen current* 200 160 238 madc grid current* 38 60 53 madc driving power* 360 405 340 w useful power output*# 28.9 33.2 34.4 kw efficiency* 77.4 77.6 81.0 % power gain* 19.0 19.1 20.0 db * will vary from tube to tube # delivered to load (1:1.1 vswr) typical o pe r ati o n (measured data at 97.6 m h z): anode voltage 11.0 kvdc screen voltage 900 vdc grid bias voltage -200 vdc anode current 4.1 adc screen current* 235 madc grid current* 30 madc driving power* 1025 w useful power output# 36.1 kw power gain 15.5 db * will vary from tube to tube # delivered to load (1:1.1 vswr) r ange v alues for e q uip m ent d esign min nom max filament current at 10.0 volts 135 --- 146 a 4 cx 25,000 c cpi | r a d ial b ea m p ow e r tet rod e 4 cx 25,000 c 2 m echanical storage - if a tube is to be stored as a spare it should be kept in its original shipping carton, with the original packing material, to minimize the possibility of handling damage. mounting - the 4cx25,000c must be operated with its axis vertical. the base of the tube may be up or down at the convenience of the designer. socket - the eimac air-system socket type sk-320 is designed for use with the 4cx25,000c in dc or lf/ hf applications. for vhf applications a type sk-360 air-system socket is recommended. the use of the recommended air fow through an air-system socket will provide effective cooling of the base. cooling - the maximum temperature rating for the external surfaces of this tube is 250c, and suffcient forced-air cooling must be used in all applications to keep the temperature of the anode (at the base of the cooling fns) and the temperature of the ceramic/metal seals comfortably below this rated maximum. it is considered good engineering practice to design for a maximum anode core temperature of 225c. temper - ature-sensitive paints are available for checking base and seal temperatures before any design is fnalized. cpi eimac application bulletin #20 titled measuring tem - perature of power grid tubes is available on request. it is also good practice to allow for variables such as dirty air flters, rf seal heating, and the fact that the anode cooling fns may not be clean if the tube has been in service for a considerable length of time. special attention is required in cooling the center of the stem (base), by means of special directors or some other provision. an air interlock system should be incorporated in the design to automatically remove all voltages from the tube in case of even partial failure of the tube cooling air. sensing exhaust air temperature is recommended. minimum air fow requirements for a maximum anode temperature of 225c (or a maximum outlet air tempera - ture of 160c, whichever is reached frst) for various altitudes and dissipation levels are listed on page 4. pressure drop values are approximate and are for the tube anode cooler only. pressure drop in a typical instal - lation will be higher because of system loss and back pressure in ducting. when long life and consistent performance are factors cooling in excess of minimum requirements is normally benefcial. if all cooling air is not passed around the base of the tube and through the socket, then arrangements must be made to assure adequate cooling of the tube base and the socket contacts. movement of cooling air around the base of the tube accomplishes a double purpose in keeping the tube base and the socket contact fngers at a safe operating temperature. the contact fngers in the socket are made of beryllium copper. if this material is allowed to reach 150c and held there for an appreciable length of time the fngers may lose their temper, or springy characteristics. if this were to happen poor contact and resultant arcing can take place which can burn/melt the metal at the tube surface, which is a part of the vacuum envelope. cata - strophic tube loss could occur. air fow must be applied before or simultaneously with the application of power, including the tube flament and should normally be maintained for a short period of time after all power is removed to allow for tube cool down. pressure drop will be higher if the sk-360 socket is used unless additional air passages are provided around the mounted socket. 4 cx 25,000 c cpi | r a d ial b ea m p ow e r tet rod e 4 cx 20,000 c 3 inlet air temperature = 25c anode air flow pressure dissipation (cfm) drop (kilowatts) (in. of water) sea level 12.5 257 0.6 15.0 367 1.0 17.5 498 1.5 20.0 652 2.4 5000 feet 12.5 311 0.6 15.0 444 1.1 17.5 603 1.7 20.0 789 2.7 10,000 feet 12.5 377 0.7 15.0 537 1.2 17.5 730 1.9 20.0 955 3.0 inlet air temperature = 35c anode air flow pressure dissipation (cfm) drop (kilowatts) (in. of water) sea level 12.5 299 0.7 15.0 426 1.2 17.5 579 1.9 20.0 758 2.9 5000 feet 12.5 362 0.7 15.0 516 1.3 17.5 701 2.1 20.0 917 3.3 10,000 feet 12.5 438 0.8 15.0 625 1.4 17.5 848 2.4 20.0 1111 3.8 inlet air temperature = 50c anode air flow pressure dissipation (cfm) drop (kilowatts) (in. of water) sea level 12.5 379 0.9 15.0 540 1.6 17.5 733 2.6 20.0 960 4.1 5000 feet 12.5 459 1.0 15.0 654 1.8 17.5 888 3.0 20.0 1162 4.7 10,000 feet 12.5 555 1.1 15.0 791 2.0 17.5 1075 3.4 20.0 1407 5.4 elect r ical absolute maximum ratings - values shown for each type of service are based on the absolute system and are not to be exceeded under any service conditions. ratings are limiting values outside which the serviceability of the tube may be impaired . in order not to exceed absolute ratings the equipment de - signer has the responsibility of determining an average de - sign value for each rating below the absolute value of that rating by a safety factor so that the absolute values will never be exceeded under any usual conditions of supply- voltage variation, load variation, or manufacturing variation in the equipment itself. it does not necessarily follow that combinations of absolute maximum ratings can be attained simultaneously . filament warmup - in-rush current should be limited to 300 amperes. a suitable step-start procedure can ac - complish this, or an impedance-limited transformer de - signed for this purpose can be used. once normal flament voltage has been applied, a warm-up period of fve seconds is generally suffcient before commencing operation at full power . filament operation - this tube is designed for com - mercial service, with no more than one normal off/on fla - ment cycle per day. if additional cycling is anticipated it is recommended the user contact an applications engineer at cpi eimac for additional information . 4 cx 25,000 c cpi | r a d ial b ea m p ow e r tet rod e 4 cx 25,000 c 4 4 cx 25,000 c cpi | 4 c w50,000j cpi | r a d ial b ea m p ow e r tet rod e 4 cx 25,000 c with a new tube, or one that has been in storage for some period of time, operation with flament voltage only applied for a period of 30 to 60 minutes is recommended before full operation begins. this allows the active getter mounted within the flament structure to absorb any residual gas molecules, which have accumulated during storage. at rated (nominal) flament voltage the peak emission capa - bility of the tube is many times that needed for communica - tions service. a reduction in flament voltage will lower the flament temperature, which will substantially increase life expectancy. the correct value of flament voltage should be determined for the particular application. it is recom - mended the tube be operated at full nominal voltage for an initial stabilization period of 100 to 200 hours before any action is taken to operate at reduced voltage. the voltage should gradually be reduced until there is a slight degrada - tion in performance (such as power output or distortion.) the voltage should then be increased a few tenths of a volt above the value where performance degradation was noted for operation. the operating point should be re - checked after 24 hours . filament voltage should be closely regulated when voltage is to be reduced below nominal in this manner, to avoid any possible adverse infuence by normal line voltage varia - tions. periodically throughout the life of the tube the procedure outlined above for voltage reduction should be repeated with voltage reset as required, to assure best tube life. filament voltage should be measured at the tube base or socket with a known-accurate rms-responding meter. eimac application bulletin #18 titled extending transmit - ter tube life contains valuable information and is avail - able on request . electrode dissipation ratings - the maximum dissipation ratings for the 4cx25,000c must be respected to avoid damage to the tube. an exception is the anode dissipation which may be permitted to rise above the rated maximum during brief periods (ten seconds maximum) such as may occur during tuning . grid operation - the maximum rated control grid dis - sipation is 200 watts, determined approximately by the product of the dc grid current and the peak positive grid voltage. a protective spark-gap device should be con - nected between the control grid and the cathode to guard against excessive voltage. the maximum dc grid voltage (bias) is -1.5 kvdc . screen operation - the maximum screen grid dissipa - tion is 450 watts. with no ac applied to the screen grid, dissipation is simply the product of dc screen voltage and the dc screen current. with modulation dissipation is de - pendent on rms screen voltage and rms screen current . cw operation at vhf frequencies above the maximum frequency rating for cw service may add signifcantly to the total screen grid dissipation due to the ac charging current in internal capacitance between the screen grid and anode. operation at lower anode voltage and/or lower drive levels will reduce the dissipation . anode voltage, anode loading, or bias voltage must never be removed while flament and screen voltages are pres - ent, since screen dissipation ratings will be exceeded. a protective spark-gap device should be connected between the screen grid and the cathode to guard against excessive voltage. the tube may exhibit reversed (negative) screen current under some operating conditions. the screen supply volt - age must be maintained constant for any values of negative and positive screen current which may be encountered. dangerously high anode current may fow if the screen power supply exhibits a rising voltage characteristic with negative screen current. stabilization may be accom - plished with a bleeder resistor connected from screen to cathode to assure that net screen supply current is always positive. this is essential if a series electronic regulator is employed. fault protection - in addition to the normal anode over-current interlock, screen current interlock, and cool - ing air fow interlock, the tube must be protected from in - ternal damage caused by an internal anode arc which may occur at high voltages. a protective resistance of approx. 5 to 10 ohms, 500 watts should always be connected in se - ries with the tube anode to absorb power supply stored en - ergy if an internal arc should occur. if power supply stored energy is high an electronic crowbar, which will discharge power supply capacitors in a few microseconds after the start of an arc, is recommended. the protection criteria for each electrode supply is to short each electrode to ground, one at a time, through a vacuum relay switch and a 6-inch section of #30 awg copper wire. the wire will remain in - tact if protection is adequate. eimacs application bulletin #17 titled fault protection contains considerable detail and is available on request. high voltage - normal operating voltages used with this tube are deadly. the equipment must be designed properly and operating precautions must be followed. design all equipment so that no one can come in contact with high voltages. all equipment must include safety enclosures for 5 high voltage circuits and terminals, with interlock switch - es to open primary circuits of the power supply and to discharge high voltage capacitors whenever access doors are opened. interlock switches must not be bypassed or cheated to allow operation with access doors open. always remember that high voltage can kill. radio-frequency radiation - avoid exposure to strong rf felds even at relatively low frequency. ab - sorption of rf energy by human tissue is dependent on frequency. under 300 mhz most of the energy will pass completely through the human body with little attenuation or heating effect. public health agencies are concerned with the hazard, and the published osha (occupational safety and health administration) or other local recom - mendations to limit prolonged exposure of rf radiation should be followed. interelectrode capacitance - the actual internal electrode capacitance of a tube is infuenced by many variables in most applications, such as stray capacitance to the chassis, capacitance added by the socket used, stray capacitance between tube terminals and wiring effects. to control the actual capacitance values within the tubes, as the key component involved, the industry and military services use a standard test procedure as described in electronic industries association standard rs-191. this requires the use of specially constructed test fxtures which effectively shield all external tube leads from each other and eliminates any capacitance reading to ground. the test is performed on a cold tube. other fac - tors being equal, controlling internal tube capacitance in this way normally assures good interchangeability of tubes over a period of time, even when the tube may be made by different manufacturers. the capacitance values shown in the manufacturers technical data, or test specifcations, normally are taken in accordance with standard rs-191. the equipment designer is therefore cautioned to make al - lowance for the actual capacitance values which will exist in any normal application. measurements should be taken with the socket and mounting which represent approxi - mate fnal layout if capacitance values are highly signif - cant in the design. special applications - when it is desired to oper - ate this tube under conditions widely different from those listed here, write to cpi mpp, eimac operation, applica - tions engineering, 607 hansen way, palo alto, ca 94304 u.s.a. 4 cx 25,000 c cpi | r a d ial b ea m p ow e r tet rod e 4 cx 25,000 c operating hazards proper use and safe operating practices with respect to power tubes are the responsibility of equipment manufacturers and users of such tubes. all persons who work with and are exposed to power tubes, or equipment that utilizes such tubes, must take precau - tions to protect themselves against possible serious bodily injury. do not be careless around such products. the operation of this tube may involve the following hazards, any one of which, in the absence of safe operating practices and pre - cautions, could result in serious harm to personnel. high voltage C normal operating voltages can be deadly. remember that high voltage can kill. low-voltage high-current circuits - personal jewelry, such as rings, should not be worn when working with flament contacts or connectors as a short circuit can produce very high current and melting, resulting in severe burns. rf radiation C exposure to strong rf felds should be avoided, even at relatively low frequencies. cardiac pacemakers may be affected. hot surfaces C surfaces of tubes can reach temperatures of several hundred c and cause serious burns if touched for several minutes after all power is removed. material compliance - this product and package conforms to the conditions and limitations specifed in 49cfr 173.424 for radioactive material, excepted package-instruments or articles, un2910. in addition, this product and package contains no beryllium oxide (beo). 6 4 cx 25,000 c cpi | r a d ial b ea m p ow e r tet rod e 4 cx 25,000 c 7 4 cx 25,000 c cpi | r a d ial b ea m p ow e r tet rod e 4 cx 25,000 c 8 |
Price & Availability of 4CX25-000C11 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |