rhombus transformers & magnetic products industries inc. name: sheet: date: rhombus p/n: cust p/n: 15801 chemical lane, huntington beach, ca 92649-1595 phone: (714) 898-0960 fax: (714) 896-0971 www.rhombus-ind.com 10/23/97 1 of 1 10base-t/ethernet isolation transformer parameter min. max. units open circuit inductance 140 m hy leakage inductance 0.2 m hy interwinding capacitance (c w/w )12pf rise time 3.5 ns et 2.7 v m s primary dc resistance 0.3 ohms secondary dc resistance 0.3 ohms high potential test 2000 v rms test conditions: 100mv @ 100 khz operating temp. range -45 0 c to +85 0 c ieee 802.3 & ecma compatible schematic diagram: physical dimensions all dimensions in inches (mm): turns ratio 1ct:1ct & 1ct:1.41ct* *pins 6 & 8 : 9 & 11 T-13006 flammability: materials used in the production of these units meet requirements of ul94-vo and iec 695-2-2 needle flame test. parts shipped in anti-static tubes. 19 pieces per tube .300 (7.62) .285 (7.24) max. .008 r (0.20) .365 (9.27) max. .010 (0.25) typ. .120 (3.05) min. .205 (5.21) max. .020 (0.51) .885 (22.48) max. .050 (1.27) typ. .020 (0.51) typ. .100 (2.54) typ. a surface mount version of this part is available. add suffix "g" to part number (T-13006g)
|