Part Number Hot Search : 
HC705 SKHI1006 NKD135 PEB22716 6K6FK 13V99 3C272M CY3093
Product Description
Full Text Search
 

To Download SA963460 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  all technical caracteristics are subject to change without previous notice. caract?ristiques sujettes ? modifications sans pr?avis. p p p p r r r r o o o o u u u u d d d d t t t t o o o o s s s s e e e e r r r r v v v v e e e e y y y y o o o o u u u u celduc ? ? ? ? r e l a i s page 1 / 6f/gb s/mon/SA963460/b/18/11/2008 SA963460 celpac ? ? relais statique largeur 22,5mm entraxe de montage 47,6mm compatible boitier "hochey puck". relais synchrone sp?cialement adapt? aux charges r?sistives. 22,5mm pitch solid state relay for space-saving design. mounting compatible with sandard "hockey puck" ssrs (47,6mm between screws) zero cross solid state relay specially designed for resistive loads. ? sortie thyristors hautes performances technologie tms 2 (*) permettant une longue dur?e de vie : 24 ? 600vac 35a . new h igh e fficiency back to back thyristors on output with tms 2 technology(*) for a long lifetime expectancy: 24 to 600vac 35a . ? large plage de contr?le: 3,5 - 32vdc avec un courant de commande r?gul?. led de visualisation sur l'entr?e de couleur jaune. protection aux surtensions sur l'entr?e int?gr?e. large control range: 3.5-32vdc with input current limiter. yellow led visualization on the input. input over-voltage protection. ? protection ip20 avec capot de protection (1k522000), voir option volets ip20 protection with cover (1k522000) or in option by flaps ? construit en conformit? aux normes en60947-4-3 (iec947-4-3) et en60950/vde0805 (isolement renforc?) -ul-cul en cours designed in conformity with en60947-4-3 (iec947-4-3) and en60950/vde0805 (reinforced insulation) -ul-cul pending output : 24-600vac 35a input : 3,5-32vdc (*) : thermo mechanical stress solution relais statique monophas? de puissance power solid state relay typical application: 10kw resistor (ac-51 load) on 400 vac application typique: resistance 10 kw (cat?gorie ac-51) en 400 vac dimensions : avec capot transparent/ with transparent cover 2/t1 1/l1 a1/+ a2/- led fixation preliminary 400vac livr? avec capot transparent/ delivered with transparent cover
r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com caract?ristiques d'entr?e / control characteristics (at 25 c) dc param?tre / parameter symbol min typ max unit tension de commande / control voltage uc 3,5 5-12-24 32 v courant de commande / control current (@ uc ) ic <10 <14 <14 ma tension de non fonctionnement / release voltage uc off 2 v led d'entr?e / input led jaune / yellow tension inverse / reverse voltage urv 32 v tension de transil d'entr?e / clamping voltage (transil) uclamp 36 v immunit? / input immunity : en61000-4-4 2kv immunit? / input immunity : en61000-4-5 2kv caract?ristiques de sortie / output characteristics (at 25 c) param?tre / parameter conditions symbol min typ. max unit plage de tension utilisation / operating voltage range ue 24 400 600 v rms tension de cr?te / peak voltage up 1200 v niveau de synchronisme / zero cross level usync 20 v tension amor?age / latching voltage ie nom ua 10 v courant nominal / nominal current (ac-51) ie ac-51 35 48 a rms courant surcharge / non repetitive overload current tp=10ms (fig. 3) itsm 320 420 a chute directe ? l'?tat passant / on state voltage drop @ 25 c vt 0,85 v r?sistance dynamique / on state dynamic resistance rt 9,5 m ? puissance dissip?e (max) / output power dissipation (max value) pd 0,9x0,85xie + 0,0095 x ie 2 w r?sistance thermique jonction/semelle thermal resistance between junction to case rthj/c 0,7 0,9 k/w courant de fuite ? l'?tat bloqu? / off state leakage current @ue typ, 50hz ilk 1 ma courant minimum de charge / minimum load current iemin 5 ma temps de fermeture / turn on time @ue typ, 50hz ton max 10 ms temps d'ouverture / turn off time @ue typ, 50hz toff max 10 ms fr?quence utilisation / operating frequency range f mains f 0,1 50-60 800 hz dv/dt ? l'?tat bloqu? / off state dv/dt dv/dt 500 v/ s di/dt max / maximum di/dt non repetitive di/dt 50 a/ s i 2 t (<10ms) i 2 t 512 882 a 2 s immunit? / conducted immunity level iec/en61000-4-4 (bursts) 2kv criterion b immunit? / conducted immunity level iec/en61000-4-5 (surge) 2kv criterion a with external vdr emission conduite / conducted & emitted interference iec60947-4-3 class a for industrial applications protection court-circuit / short circuit protection voir/ see page 5 example fuse ferraz grc 25a/32a/50a input : ic = f( uc) page 2 / 6f/gb s/mon/SA963460/b/18/11/2008 celpac ? caract?ristiques g?n?rales / general characteristics (at 25 c) symbol isolement entr?e/sortie - input to output insulation ui 4000 vrms isolation sortie/ semelle - output to case insulation ui 4000 vrms r?sistance isolement / insulation resistance ri 1000 (@500vdc) m ? tenue aux tensions de chocs / rated impulse voltage uimp 4000 v degr? de protection / protection level / cei529 ip20 (with cover or flaps) vibrations / vibration withstand 10 -55 hz according to iec 60068-2-6 10/55hz 1,5 mm tenue aux chocs / shocks withstand according to iec 60068-2-27 half sinus /11ms 30 g n temp?rature de fonctionnement / ambient temperature (no icing, no condensation) - -40 /+80 c temp?rature de stockage / storage temperature (no icing, no condensation) -40/+125 c humidit? relative / ambient humidity hr 40 to 85 % poids/ weight 85 g conformit? / conformity en60947-4-3 (iec947-4-3) conformit? / conformity en60950 / ul/cul plastique du boitier / housing material pa 6 ul94v0 semelle / base plate aluminium 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 0 0 2 4 6 8 10 12 14 0 uc (vdc) ic(ma) celduc ? ? ? ?
r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com celduc ? ? ? ? page 3 / 6f/gb s/mon/SA963460/b/18/11/2008 fig 3 : courants de surcharges / overload currents fig. 2 courbes thermiques & choix dissipateur thermique / thermal curves and heatsink choice ?> warning ! semiconductor relays don't provide any galvanic insulation between the load and the mains. always use in conjunction with an adapted circuit breaker with isolation feature or a similar device in order to ensure a reliable insulation in the ev ent of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration ...). 1 -itsm non r?p?titif sans tension r?appliqu?e est donn? pour la d?termination des protections. 1 - no repetitive itsm is given without voltage reapplied . this curve is used to define the protection (fuses). 2 -itsm r?p?titif est donn? pour des surcharges de courant (tj initiale=70 c). attention : la r?p?tition de ces surcharges de courant diminue la dur?e de vie du relais. 2 - repetitive itsm is given for inrush current with initial tj = 70 c. in normal operation , this curve musn't be exceeded. be careful, repeated surge currents decrease life expectancy of the ssr. ?> attention ! les relais ? semi-conducteurs ne procurent pas d'isolation galvanique entre le r?seau et la charge. ils doivent ?tre utilis? s associ?s ? un disjoncteur avec propri?t? de sectionnement ou similaire, afin d'assurer un sectionnement fiable en amont de la l igne dans l'hypoth?se d'une d?faillance et pour tous les cas o? le relais doit ?tre isol? du r?seau (maintenance ; non utilisation sur un e longue dur?e...). 400 350 300 250 200 150 100 50 10 1 0,1 0,01 time (s) itsm (apeak) 1 2 surcharge de courant : itsm(apeak) = f(t) pour mod?le 35a (itsm=400a) surge current : itsm (apeak) =f(t) for 35a models with itsm=400a courbe de puissance dissip?e en fonction du courant commut? et du cycle de marche , de la r?sistance thermique du dissipateur et de la temp?rature ambiante. power dissipation curve in compliance with nominal load current, on/off duty cycle, thermal resistance of the heatsink and ambient temperature. celpac ? 0 5 10 15 20 25 30 35 40 45 50 0 0 5 10 15 20 25 30 35 40 45 50 0 courant de charge / rms load current (a) puissance dissip?e / power dissipation (w) 0 10 20 30 40 50 60 70 80 90 100 0 0 5 10 15 20 25 30 35 40 45 50 0 temp?rature ambiante / ambient temperature ( c) 3k/w 12k/w 6k/w 2k/w 1,5k/w full on state 50% on state 1k/w 4k/w duty cycle 90% i max = 48a @ tcase = 85 c i max = 34a @ tcase = 100 c
r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com page 4 / 6f/gb s/mon/SA963460/b/18/11/2008 celpac ? celpac ? raccordement de puissance / power wiring nombre de fils / number of wires mod?le de tournevis / screwdriver type couple de serrage recommand? 1 2 recommended torque fil rigide (sans embout) solid (no ferrule) fil multibrins (avec embout) fine stranded (with ferrule) fil rigide (sans embout) solid (no ferrule) fil multibrins (avec embout) fine stranded (with ferrule) m5 n.m 1,5 ... 10 mm 2 awg16....awg8 1,5 ... 6 mm 2 awg16....awg10 1,5 ... 10 mm 2 awg16....awg8 1,5 ... 6 mm 2 awg16....awg10 pozidriv 2 2 raccordement / connections celduc ? ? ? ? fastons : nous consulter / consult us directement avec fils avec ou sans embouts direct connection with wires with or without ferrules avec cosses/ with ring terminals washer for vibrations celpac ? raccordement de commande / control wiring nombre de fils / number of wires mod?le de tournevis / screwdriver type couple de serrage recommand? 1 2 recommended torque fil rigide (sans embout) solid (no ferrule) fil multibrins (avec embout) fine stranded (with ferrule) fil rigide (sans embout) solid (no ferrule) fil multibrins (avec embout) fine stranded (with ferrule) m3,5 n.m 0,75 ... 2,5 mm 2 0,75 ... 2,5 mm 2 0,75 ... 2,5 mm 2 0,75 ... 2,5 mm 2 pozidriv 2 or 0,8 x5,5mm 1,2
r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com s/mon/SA963460/b/18/11/2008 celpac ? page 5 / 6f/gb celduc ? ? ? ? montage / mounting: ?> l es relais statiques de la gamme celpac ? r?f?rences sa doivent ?tre mont?s sur dissipateur thermique. une gamme ?tendue de dissipateurs est disponible. voir exemples ci dessous et la gamme "wf" sur www.celduc.com. sa celpac ? ssrs must be mounted on heatsinks. a large range of heatsinks is available. see below some examples and "wf" range on www.celduc.com. ?> pour le montage du relais sur dissipateur utiliser de la graisse thermique for heatsink mounting, it is necessary to use thermal grease exemple avec un dissipateur wf311100/ example with a wf311100 heatsink ?> la r?sistance thermique de ce dissipateur thermique d?pend du montage qui doit ?tre vertical, du confinement du relais, de la ventilation de l'armoire. la r?sistance thermique de ce dissipateur wf311100, en fonction de la puissance dissip?e est comprise g?n?ralement suivant l'application et l'installation entre 2k/w et 3k/w. thermal resistance of wf311100 heatsink depends on mounting which must be vertical, confinement of the ssr, ventilation(fan) in the cabinet. generally, thermal resistance (rth) is between 2,2 ? 3,2k/w depending on application and installation en fonction de la temp?rature ambiante ( 40 c sur l'exemple), du cycle de marche ( g?n?ralement 90%), on peut d?terminer le courant maximum. dans ce cas avec un dissipateur ? 3k/w, nous obtenons alors un courant de 23a. dans le cas d'une bonne ventilation, la rth du dissipateur va diminuer, dans ce cas le courant peut augmenter. according ambient temperature ( 40 c in this example), on/off duty cycle ( often take 90%), we can determine the maximum current. in this example with an heatsink of 3k/w we can drive 23a. in case of a good ventilation (fan) , the heatsink rth decreases and we can use the ssr at an higher current (32a in the example with 2k/w) options / options: ?> l es relais statiques de la gamme celpac ? r?f?rence sa sont livr?s avec protection contre le toucher avec un capot transparent ( ip20). sa celpac ? ssrs are delivered with protection against touch : transparent cover (--> ip20) deux types de protection sont possibles pour une protection ip20 / 2 types of protection are possible for ip20 a) volets de protection / flaps protection b) capot transparent de protection/ transparent cover des ?tiquettes de rep?rage sont aussi disponibles. montage sur volets ou sur capot transparent. marking labels are also possible. mounting on flaps or transparent cover versions pr?mont?es sal en 22,5mm, sam en 45mm/ ready to use versions sal (22,5mm); sam (45mm) volet/ flap + etiquette/ + marking label capot/ cover + etiquette/ + marking label ready to use = sal963460 (1k52300) (1mz09000) (1k522000) (1mz09000) (SA963460 + wf311100) (fan) 0 5 10 15 20 25 30 35 40 45 50 0 0 5 10 15 20 25 30 35 40 45 50 0 courant de charge / rms load current (a) puissance dissip?e / power dissipation (w) 0 10 20 30 40 50 60 70 80 90 100 0 0 5 10 15 20 25 30 35 40 45 50 0 temp?rature ambiante / ambient temperature ( c) 3k/w 12k/w 6k/w 2k/w 1,5k/w full on state 50% on state 1k/w 4k/w duty cycle 90%
r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com s/mon/SA963460/b/18/11/2008 celpac ? page 6 / 6f/gb celduc ? ? ? ? application typiques / typical loads ?> les produit sa sont d?finis principalement pour charge r?sistive ac-51 (chauffage). sa products are specially designed for ac-51 r?sistive load (heating). protection / protection : ?> la protection d'un relais statique contre les court-circuits de la charge d?pend du type de coordination souhait?e. deux types de coordination sont admis, le type 1 ou le type 2. a) la coordination de type 1 exige qu?n conditions de court-circuit, l?ppareil ne cause pas de danger aux personnes ou ? l?n stallation et peut ne pas ?tre en ?tat de fonctionnement pour d?utres services sans r?paration ou remplacement de pi?ces. dans ce cas, mettre une protection adapt?e ? l'installation avec un risque de maintenance sur le relais. b) la coordination de type 2 exige qu?n conditions de court-circuit, l?ppareil ne cause pas de danger aux personnes et ? l?n stallation et doit convenir ? un usage ult?rieur. dans le cas d'une coordination de type "2" en conformit? avec la norme en60947-4-1, la protection doit ?tre faite par fusibles rapides avec des i 2 t = 1/2 i 2 t du relais . un test en laboratoire a ?t? effectu? sur les fusibles de marque ferraz. une protection par mcb ( disjoncteurs modulaires miniatures) est aussi possible. voir notre note application ( protection ssr) et utiliser des relais avec i 2 t >5000a2s ?> ssrs protection against short circuit of the load depends on the coordination wished. two types of coordination are permissible, type 1 or type 2. a) type 1 coordination requires that, under short-circuit conditions, the device shall cause no danger to perso ns or to the installation and may not be suitable for further service without repair and replacement of parts. in this case, use a protection adapted to the installation with the risk of ssr maintenance after a short circuit. b) type 2 coordination requires that, under short-circuit conditions, the device shall cause no danger to persons or to the ins tallation and shall be suitable for further use. in case of type 2 coordination, to protect the ssr against a short-circuit of the load , use a fuse with an i2t value = 1/2 i2 t value specified page 2. a test has been made with ferraz fuses . it is possible to protect ssr by mcb ( miniature circuit breaker). in this case, see application note ( ssr protection) and use a ssr with high i2t value (5000a2s minimum). emc : ?> immunit? : nous sp?cifions dans nos notices le niveau d'immunit? de nos produits selon les normes essentielles pour ce type de produit, c'est ? dire en61000-4-4 &5. immunity : we give in our data-sheets the immunity level of our ssrs according to the main standards for these products: en61000-4-4 &5. ?> emission: nos relais statiques sont principalement con?us et conformes pour la classe d'appareils a (industrie). l'utilisation du produit dans des environnements domestiques peut amener l'utilisateur ? employer des moyens d'att?nuation suppl?mentaires. en effet, les relais statiques sont des dispositifs complexes qui doivent ?tre interconnect?s avec d'autres ma teriels (charges, cables, etc) pour former un syst?me. etant donn? que les autres materiels ou interconnexions ne sont pas de la respon sabilit? de celduc ? , il est de la responsabilit? du r?alisateur du syst?me de s'assurer que les syst?mes contenant des relais statiques satisfont aux prescriptions de toutes les r?gles et r?glements applicables au niveau des syst?mes. consulter celduc ? qui peut vous conseiller ou r?aliser des essais dans son laboratoire sur votre application. emission: celduc ? ssrs are mainly designed in compliance with standards for class a equipment (industry). use of this product in domestic environments may cause radio interference. in this case the user may be required to employ additionnal devices to reduce noise. ssrs are complex devices that must be interconnected with other equipment (loads, cables, etc.) to form a system. because the other equipment or the interconnections may not be under the control of celduc ? , it shall be the responsability of the system integrator to ensure that systems containing ssrs comply with the requirement of any rules and regulations applicable at the system level. consult celduc ? for advices. tests can be preformed in our laboratory. ces sp?cifications peuvent ?voluer sans pr?avis/ specifcations are subject to change without notice


▲Up To Search▲   

 
Price & Availability of SA963460

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X