If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
key features ? wide input, 3.0-5.5 vdc ? programmable output, 0.75 - 3.6 vdc ? under voltage protection ? short circuit protection ? remote sense ? remote on/off ? design for environment (dfe) ? european commission directive 2002/95/ec (rohs) compliant e datasheet dc/dc regulator input 3.0 - 5.5 v output 16 a pmb 4518t wp the pmb series of sil dc/dc regulators (pol) are intended to be used as local distributed power sources in distributed power architec - ture level 4. the single in-line design makes the pmb series suitable for applications where boardspace is limited. the high efficiency and high reliability of the pmb series makes them particularly suited for the communications equipment of today and tomorrow. these products are manufactured using the most advanced technologies and materials to com - ply with environmental requirements. designed to meet high reliability requirements of systems manufacturers, the pmb responds to world-class specifications. ericsson power modules is an iso 9001/14001 certified supplier. contents product program . . . . . . . . . . . . . . . . . . . . . . 2 mechanical data . . . . . . . . . . . . . . . . . . . . . . 2 connections . . . . . . . . . . . . . . . . . . . . . . . . . 2 absolute maximum ratings . . . . . . . . . . . . . 3 input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 product qualification specification . . . . . . . . 4 safety specification . . . . . . . . . . . . . . . . . . . 5 adjusted to 1.0 v out - data . . . . . . . . . . . . . 6 adjusted to 1.2 v out - data . . . . . . . . . . . . . 9 adjusted to 1.5 v out - data . . . . . . . . . . . . 1 2 adjusted to 1.8 v out - data . . . . . . . . . . . . 1 5 adjusted to 2.5 v out - data . . . . . . . . . . . . 1 8 adjusted to 3.3 v out - data . . . . . . . . . . . . 2 1 emc specification . . . . . . . . . . . . . . . . . . . . 2 4 operating information . . . . . . . . . . . . . . . . . 2 4 thermal considerations . . . . . . . . . . . . . . . 2 7 soldering information . . . . . . . . . . . . . . . . . 2 8 delivery package information . . . . . . . . . . . 2 8 reliability . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 8 compatibility with rohs requirements . . . . 2 8 sales offices and contact information . . . . 2 9
en/lzt 146 049 r4a ? ericsson power modules, march 2007 pmb 4518t wp datasheet 8 , 8 0 [ 0 . 3 4 6 ] 7 , 4 0 [ 0 . 2 9 1 ] 5 1 , 8 0 [ 2 . 0 3 9 ] 4 8 , 2 6 [ 1 . 9 0 0 ] r e c o m m e n d e d f o o t p r i n t ( c u s t o m e r b o a r d ) , n o c o m p o n e n t s w i t h i n b o r d e r . h o l e s : ? 1 , 0 [ 0 . 0 4 ] t h r o u g h p l a t e d h o l e s w i t h ? 1 , 5 [ 0 . 0 6 ] p a d s o n b o t h s i d e s . n o t e 1 : f o r o t h e r p i n l e n g t h s , r e f e r t o p r o d u c t p r o g r a m / o r d e r i n g i n f o r m a t i o n 1 2 3 4 5 6 7 8 9 1 0 d i m e n s i o n s i n m m [ i n c h ] t o l e r a n c e s ( u n l e s s s p e c i f i e d ) : x , x + / - 0 , 5 [ 0 . 0 2 ] x , x x + / - 0 , 2 5 [ 0 . 0 1 ] e 7 , 0 [ 0 . 2 7 ] 8 , 5 [ 0 . 3 3 ] m a x c h o k e 3 5 , 5 6 [ 1 . 4 0 0 ] 4 8 , 2 6 [ 1 . 9 0 0 ] 2 , 5 4 [ 0 . 1 0 0 ] ( 7 x ) ( 1 , 2 7 [ 0 . 0 5 ] ) 1 3 , 2 0 [ 0 . 5 2 0 ] 5 0 , 8 [ 2 . 0 0 ] p i n l e n g t h 3 , 6 0 [ 0 . 1 4 2 ] ( n o t e 1 ) 1 1 mechanical data product program delivery option m.o.q. suffix example tray 100 pcs /b pmb 4xxxt wp /b ordering information * input voltage limited to 3.8-5.5v for 3.3 vout and for output voltages of 3.3v and 4.5-5.5 for output voltages above 3.3v. v i v o /i o max p o max ordering no. comment output 1 3.0-5.5 v* 0.8-3.6 v/16 a 52.8 w pmb 4518t wp standard version 3.0-5.5 v 1.0 v/16 a 16.0 w pmb 4118na wp on request 3.0-5.5 v 1.2 v/16 a 19.2 w pmb 4118la wp on request 3.0-5.5 v 1.5 v/16 a 24.0 w pmb 4218h wp on request 3.0-5.5 v 1.8 v/16 a 28.8 w pmb 4218g wp on request 3.0-5.5 v 2.5 v/16 a 40.0 w pmb 4419 wp on request 3.8-5.5 v 3.3 v/16 a 52.8 w pmb 4510 wp on request option suffix example positive remote control logic p pmb 4518t wpp en/lzt 146 049 r4a ? ericsson power modules, march 2007 pmb 4518t wp datasheet characteristics min typ max unit t ref operating reference temperature, see pg. 27 -45 +115 ?c t s storage temperature -55 +125 ?c v i input voltage -0.3 +5.5 vdc characteristics conditions min typ max unit v i input voltage range 3.0 5.5 vdc v ioff turn-off input voltage ramp from higher voltage, v out = 1.0- 2.5 v, v in = 3.3 v 2.2 vdc ramp from higher voltage, v out = 3.3 v, v in = 5.0 v 3.4 v ion turn-on input voltage ramp from lower voltage, v out = 1.0- 2.5 v, v in = 3.3 v 2.7 vdc ramp from lower voltage, v out = 3.3 v, v in = 5.0 v 3.5 c i input capacitance 20 f p ii input idling power i o = 0 a, v i = 5 v 680 mw p rc input stand-by power (rc active) non operation, v i = 5 v 7.5 mw v i ac input ripple 1) 20 hz ... 5 mhz, i o max, v i = 5 v 400 mv input stress in excess of absolute maximum ratings may cause permanent damage. absolute maximum ratings, sometimes referred to as no destruction limits, are normally tested with one parameter at a time exceeding the limits of output data or electrical characteristics. if exposed to stress above these limits, function and performance may degrade in an unspecified manner. absolute maximum ratings t ref = -30 ... +90 ?c, v i = 3.0...5.5 v unless otherwise specified typ values specified at: t ref = +25 ?c, v i nom, i o max = 16 a 1) measured with 2 x 22 f ceramic capacitors connections weight 7.7g pin designation function 1 + out positive output 2 + out positive output 3 + sense positive sense 4 + out positive output 5 gnd ground 6 gnd ground 7 + in positive input 8 + in positive input 9 vadj output voltage adjust 10 rc remote control pins material: copper alloy plating: matte tin over nickel en/lzt 146 049 r4a ? ericsson power modules, march 2007 pmb 4518t wp datasheet characteristics random vibration iec 60068-2-64 frequency acceleration density 5 ... 500 hz 0.5 g 2 /hz mechanical shock (half sinus) iec 60068-2-27 peak acceleration duration 50 g 11 ms lead integrity iec 60068-2-21 ub simultaneous bending all leads temperature cycling jesd22-a104-b g temperature number of cycles -40 ... +125 ?c 300 accelerated damp heat jesd22-a101-b temperature humidity duration bias +85 ?c 85 % rh 1000 hours max input voltage solderability iec 60068-2-54 (aged according to jesd22-a101- b, 240h no bias) solder immersion depth time for onset of wetting wetting force 2 mm < 2.5 s > 200 mn/m cold (in operation) iec 60068-2-1 temperature duration -45 ?c 72 h high temperature storage jesd22-a103-b a temperature duration +125 ?c 1000 h product qualification specification fundamental circuit diagram gnd gnd pw m +in +out +sense vadj controller re f gnd error amplifier rc rc gnd block en/lzt 146 049 r4a ? ericsson power modules, march 2007 pmb 4518t wp datasheet ericsson power modules dc/dc converters and dc/dc regulators are designed in accordance with safety standards iec/en/ul 60 950, safety of information technology equipment. iec/en/ul60950 contains requirements to prevent injury or damage due to the following hazards: ? electrical shock ? energy hazards ? fire ? mechanical and heat hazards ? radiation hazards ? chemical hazards on-board dc-dc converters are defined as component power supplies. as components they cannot fully comply with the provisions of any safety requirements without conditions of acceptability. it is the responsibility of the installer to ensure that the final product housing these components complies with the requirements of all applicable safety standards and directives for the final product. component power supplies for general use should comply with the requirements in iec60950, en60950 and ul60950 safety of information technology equipment. there are other more product related standards, e.g. iec61204-7 safety standard for power supplies", ieee802.3af ethernet lan/man data terminal equipment power, and ets300132-2 power supply interface at the input to telecommunications equipment; part 2: dc, but all of these standards are based on iec/en/ul60950 with regards to safety. ericsson power modules dc/dc converters and dc/dc regulators are ul 60 950 recognized and certified in accordance with en 60 950. the flammability rating for all construction parts of the products meets ul 94v-0. the products should be installed in the end-use equipment, in accordance with the requirements of the ultimate application. normally the output of the dc/dc converter is considered as selv (safety extra low voltage) and the input source must be isolated by minimum double or reinforced insulation from the primary circuit (ac mains) in accordance with iec/en/ul 60 950. safety specification isolated dc/dc converters. the input voltage to the dc/dc regulator is selv (safety extra low voltage) and the output remains selv under normal and abnormal operating conditions. it is recommended that a slow blow fuse with a rating twice the maximum input current per selected product be used at the input of each dc/dc regulator. non-isolated dc/dc regulators. 24 v dc systems. the input voltage to the dc/dc converter is selv (safety extra low voltage) and the output remains selv under normal and abnormal operating conditions. 48 and 60 v dc systems. if the input voltage to ericsson power modules dc/dc converter is 75 v dc or less, then the output remains selv (safety extra low voltage) under normal and abnormal operating conditions. single fault testing in the input power supply circuit should be performed with the dc/dc converter connected to demonstrate that the input voltage does not exceed 75 v dc. if the input power source circuit is a dc power system, the source may be treated as a tnv2 circuit and testing has demonstrated compliance with selv limits and isolation requirements equivalent to basic insulation in accordance with iec/en/ul 60 950. it is recommended that a fast blow fuse with a rating twice the maximum input current per selected product be used at the input of each dc/dc converter. if an input filter is used in the circuit the fuse should be placed in front of the input filter. in the rare event of a component problem in the input filter or in the dc/dc converter that imposes a short circuit on the input source, this fuse will provide the following functions: ? isolate the faulty dc/dc converter from the input power source so as not to affect the operation of other parts of the system. ? protect the distribution wiring from excessive current and power loss thus preventing hazardous overheating. the galvanic isolation is verified in an electric strength test. the test voltage (v iso ) between input and output is 1500 vdc or 2250 vdc for 60 seconds (refer to product specification). leakage current is less than 1a at nominal input voltage. general information. en/lzt 146 049 r4a ? ericsson power modules, march 2007 pmb 4518t wp datasheet characteristics conditions output unit min typ max v oi output voltage adjusted setting t ref = +25 c, v i nom, i o max, r adj 80 k ? 0.98 1.00 1.02 v v o output voltage tolerance band i o = 0.01...1.0 x i o max 0.97 1.03 v idling voltage i o = 0 0.98 1.02 v line regulation v i min ... v i max, i o max 11 mv load regulation i o = 0.01...1.0 x i o max, v i nom 10 mv v tr load transient voltage deviation load step = 0.25 ... 0.75 x i o max, di/dt = 5 a/s, c o = 150 f, v i = 3.3 v 100 mv t tr load transient recovery time 60 s t coeff temperature coefficient t ref = -30 ... +90 c, i o max -0.1 0 +0.1 mv/c t s start-up time from v i connected to v o = 0.9 x v oi , i o = 0.1 ...1.0 x i o max, v i nom 8.5 ms t r ramp-up time 0.1...0.9 x v o , i o = 0.1 ...1.0 x i o max, v i nom 4 ms t r fall time, v o x 0.1 i o = i o max, v i nom 0.2 ms t r fall time, v o x 0.1 i o = 0 a, v i nom 5 s t rc off rc shut-down time to v o x 0.1 i o = i o max, v i nom 0.2 ms t rc on rc start-up time to v o x 0.9 i o = i o max, v i nom 8 ms t rc rc fall time, v o x 0.1 ... 0.9 i o = 0 a, v i nom 10 s i o output current 0 16 a p o max max output power at v o = v onom 16 w i lim current limit threshold t ref < t ref max 22 28 35 a v oac output ripple 20 hz ... 5 mhz, i o max 10 20 mv p-p efficiency - 50% load i o = 0.5 x i o max, v i = 5 v 87.2 % efficiency - 100% load i o = i o max, v i = 5 v 81 83.4 % p d power dissipation i o = i o max, v i = 5 v 3.1 3.8 w fo switching frequency i o = 0 ... 1.0 x i o max 250 300 350 khz i sense remote sense current 8 ma i i static input current v i = 3.0 v, i o = i o max, t ref = 25 c 6.7 a mtbf predicted reliability t ref = 40 c 6 million hours t ref = -30 ... +90 c, v i = 3.0 ... 5.5 v unless otherwise specified. input filter 2 x 22 f, output filter 1 x 150 f typ values specified at: t ref = +25 c and v i nom. i o max = 16 a. note: +sense connected to +out adjusted to 1.0 v out - data en/lzt 146 049 r4a ? ericsson power modules, march 2007 pmb 4518t wp datasheet output current derating at v input start-up output voltage vs. load current. available load current vs. ambient air temperature and airflow at vin = 5 v. see conditions on page 27. start-up at i o = 16 a resistive load at t ref = +25 c, vin = 3.3 v. start enabled by connecting v in . top trace: output voltage (0.5 v/div.). bottom trace: input voltage (2 v/div.). time scale: 2 ms/div. efficiency power dissipation output characteristics adjusted to 1.0 v out - typical characteristics efficiency vs. load current and input voltage at t ref = +25 c < |