Part Number Hot Search : 
ELM7S00B M64ET WFU4N60 EDI8L HD643 E13005 RM2E1 BI600
Product Description
Full Text Search
 

To Download EUS15-120-PHBRC Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  technical enquiries email: sales@murata-ps.com, tel: + 508 339 3000 1 features: 9 48 vin, isolated, 4:1 fixed conversion ratio 9 220 watt nominal output (at 48 vin, 55 c, 200 lfm) 9 170 watt output (at 38 vin, 55 c, 200 lfm) 9 industry standard 1/8 brick footprint 9 remote enable (primary side , positive or negative) 9 over-temperature and over current protection 9 direct parallel operation for higher power applications 9 rohs compliant table 1 input characteristics notes & conditions (1) min typ. max units input voltage operating range 36 48 55 vdc input voltage absolute maximum 60 vdc turn-on threshold 36 37.5 vdc turn-off threshold 34 35.5 vdc input undervoltage lockout hysteresis voltage 2 vdc turn-on threshold 56 58 vdc turn-off threshold 55 57 vdc input overvoltage lockout hysteresis voltage 2 vdc maximum input current steady-state (23 a out) 5.5 adc no-load input current enabled state, on load (48 vin) 80 ma disabled input current disabled state (48 vin) 6 ma input reflected ripple current 50 ma p-p inrush current transient 0.2 a 2 s enable ? negative logic version internal 10 k pull-up to 5 v. on state range off state range -0.1 2.4 0.8 5.0 vdc vdc enable ? positive logic version internal 100 k pull-down to gnd. on state range off state range 2.4 -0.1 5.0 0.8 vdc vdc table 2 output characteristics notes & conditions (1) min typ. max units output voltage set point (vo=vin/4 +0/-0.5%) vin = 48.0 v, io = 0 a 11.94 11.98 12.0 vdc output load regulation io = 0 to 15 a 0.7 v output voltage total regulation vin = 36 to 55 v, io = 0 to 15 a, 8.3 13.75 vdc vin = 42 to 53 v, io = 0 to 15 a, 9.7 13.25 vdc output ripple voltage & noise 20 mhz bandwidth 90 150 mv p-p output current operating range 0 15 a efficiency vin = 48 v, io = 15 a 96 % turn-on time vin present: enable to 90% vout 10 ms start-up inhibit time enabled: vin applied to 90% vout 80 ms transient response (3) 25% step, 0.1a/ s, vo 160 mv recovery time 100 s maximum output capacitance (4) 3000 f bus converte r eus15-120 model
2 table 1 protection characteristics notes & conditions (1) min typ. max units output over-current shutdown non-latching 21 23 25 a re-start rate tbd msec short circuit current peak tbd ap over temperature shutdown (5) non-latching 125 130 c over temperature restart hysteresis 10 c table 2 general specifications notes & conditions (1) min typ. max units isolation voltage input to output 2250 vdc isolation resistance input to output 10 mohm storage temperature range non-condensing -40 125 c operating temperature range ambient (7) -40 100 c thermal measurement location temperature (7) see mechanical drawing for location 120 c material flammability ul 94v-0 mtbf calculated (bellcore tr-332) 1 tbd x10 6 hrs demonstrated tbd x10 6 hrs dimension 2.28l x 0.9w x 0.48h (max) (57.9l x 22.9w x 12.19h mm max) weight grams table 3 standards compliance notes & conditions (6) ul/csa 60950 basic insulation en60950 certified by tuv notes: (1) vin = 48vdc, ta = 25 c, airflow = 200 lfm for all data unless otherwise noted. (2) output ripple voltage and noise is specified when measured with no external capacitance. (3) transient response is specified without a capacitor at the output of the converter. (4) product operates with an external capac itance greater than specified. for higher values please contact a celestica represe ntative. (5) thermal shutdown is monitored at the thermal measurement location (tml). see ?mechanical information? on page 3 for tml loc ation. (6) see ?safety considerations? shown on last page. (7) de-rating curves are conducted in a cont rolled environment. end application testi ng is required to ensure the thermal meas urement location temperature is below the maximum specified. (8) recommended airflow direction is from pin 1 to pin 3, or 3 to 1 (transverse airflow). bus converte r eus15-120 model
3 mechanical information figure 1 pin assignment table 4 pin # pin name function notes & conditions 1 vi(+) positive input voltage 2 en input enable / disable referenced to vi(-). positive logic: floating = enabled negative logic: floating = disabled 3 vi(-) negative input voltage 4 vo(-) negative output voltage 5 vo(+) positive output voltage bus converter eus15-120 model
4 efficiency curves figure 2 output voltage vs. current figure 3 vo (v) vs. io (a) and vin (v) 6 7 8 9 10 11 12 13 14 0 2 4 6 8 101214161820 55 vin 48 vin 42 vin 38 vin efficiency (%) vs. iout (a) and vin (v) 88% 89% 90% 91% 92% 93% 94% 95% 96% 97% 0 2 4 6 8 101214161820 55vin 48vin 42vin 38vin bus converter eus15-120 model
5 thermal derating curves (transverse) t tml =120c airflow from pin 3 to pin 1 fi g ure 7 iout (a) vs. tamb (c) and air flow (lfm) 38 vin 0 2 4 6 8 10 12 14 16 18 20 22 24 25 35 45 55 65 75 85 100 lfm 200 lfm 300 lfm 400 lfm iout (a) vs. tamb (c) and air flow (lfm) 42 vin 0 2 4 6 8 10 12 14 16 18 20 22 24 25 35 45 55 65 75 85 100 lfm 200 lfm 300 lfm 400 lfm iout (a) vs. tam b (c) and air flow (lfm) 55 vin 0 2 4 6 8 10 12 14 16 18 20 22 24 25 35 45 55 65 75 85 100 lfm 200 lfm 300 lfm 400 lfm iout (a) vs. tamb (c) and air flow (lfm) 48 vin 0 2 4 6 8 10 12 14 16 18 20 22 24 25 35 45 55 65 75 85 100 lfm 200 lfm 300 lfm 400 lfm figure 4 figure 5 figure 6 bus converte r eus15-120 model
6 figure 8 pout (w) vs. tamb (c) and vin (v) 200 lfm 0 25 50 75 100 125 150 175 200 225 250 275 25 35 45 55 65 75 85 38 vin 42 vin 48 vin 55 vin bus converte r eus15-120 model
7 turn-on from vin (enable on) turn-on from enable (vin present) figure 9 ch3: en; ch2: vout figure 10 ch3: vin; ch2: vout vin=48v, io=15a, co=3000uf vin=48v, io=15a, co=3000uf output ripple/noise figure 11 vin=48v, io=15a vripple = 114 mvpp bus converte r eus15-120 model
safety considerations figure 12 ordering information the eus series of converters are certified to the standards list ed in the standards compliance section in the table above. i f this product is built into information technology equipment, the installation must comply with the above standard. an external input fuse (10 a recommended), mu st be used to meet the above requirements. the output of the converter [vo(+)/vo(-)] is considered to remain within selv limits when the input to the converter meets selv or tnv-2 requirements. the converters and materials meet ul 94v-0 flammability ratings. bus converte r eus15-120 model


▲Up To Search▲   

 
Price & Availability of EUS15-120-PHBRC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X