101 rk-relays 1.5 ghz microwave relay mm inch 11.2 .441 9.7 .382 20.2 .795 ? excellent high frequency characteristics isolation: min. 60db (at 1.5 ghz) insertion loss: max. 0.3db (at 900 mhz) ? v.s.w.r.: max. 1.5 (at 900mhz) ? high sensitivity in small size size: 20.2 11.2 9.7 mm .795 .441 .382 inch nominal power consumption: 200 mw (single side stable type) ? sealed construction for automatic cleaning ? latching types are also available arrangement contact coil (at 25 c, 68 f ) contact material max. switching voltage isolation max. switching current insertion loss 0.01 a 24 v dc 10 w 1.2 ghz 3 10 5 10 5 v.s.w.r. min. 60 db (at 1.5 ghz) max. 0.3 db (at 900 mhz) max. 1.5 (at 900 mhz) 2 coil latching single side stable 200 mw nominal operating power 1 coil latching 400 mw 200 mw initial contact resistance, max. (by hp4328a) 1 form c gold-clad 100 m w nominal switching capacity high frequency characteristics ( impedance 50 w ) expected life (min. operations) 5 10 6 electrical mechanical rating max. switching power 30 v dc 0.5 a 0.01 a 24 v dc 10 w (at 1.2 ghz, impedance 50 w ) 10 w characteristics initial insulation resistance* 1 operate time [set time]* 3 (at nominal voltage) approx. 6 ms [approx. 5ms] max. 60 cwith nominal coil voltage across coil and at nominal switching capacity temperature rise initial breakdown voltage* 2 between open contacts between contact and coil between contact and earth terminal 500 vrms 1,000 vrms 500 vrms min. 100 m w at 500 v dc shock resistance vibration resistance unit weight remarks * specifications will vary with foreign standards certification ratings. * 1 measurement at same location as ?nitial breakdown voltage?section * 2 detection current: 10ma * 3 excluding contact bounce time * 4 half-wave pulse of sine wave: 11ms, detection time: 10 m s * 5 half-wave pulse of sine wave: 6ms * 6 detection time: 10 m s approx. 4.4 g .155 oz min. 196 m/s 2 {20 g} min. 980 m/s 2 {100 g} functional* 4 destructive* 5 functional* 6 destructive 10 to 55 hz at double amplitude of 3 mm 10 to 55 hz at double amplitude of 5 mm conditions for operation, transport and storage (not freezing and condensing at low temperature) ambient temp. humidity ?0 c to 60 c ?0 f to 140 f 5 to 85% r.h. release time (without diode) [reset time]* 3 (at nominal voltage) * 2 approx. 3 ms [approx. 5ms] typical applications ? audio visual equipment broadcast satellite tuners vcrs, catvs, tvs ? communication equipment automobile telephones maritime telephones ? instrumentation test equipment measuring equipment ordering information 1 ex. rk l2 contact arrangement 1: standard type 1r: r type (see schematic on next page.) note: standard packing; carton: 50 pcs. case 500 pcs. nil: single side stable l: 1 coil latching l2: 2 coil latching 3, 4.5, 5, 6, 9, 12, 24 v operating function coil voltage, dc 24v specifications
rk 102 part no. rk1-3v 3 2.25 0.3 45 66.7 200 200 3.3 5 3.75 0.5 125 40 .7 200 5.5 6 4.5 0.6 180 33.3 200 6.6 9 6.75 0.9 405 22.2 200 9.9 12 9 1.2 720 16.7 200 13.2 rk1-5v rk1-6v rk1-9v rk1-12v 24 18 2.4 2,880 8.3 200 26.4 rk1-24v rk1r-3v rk1-4.5v 4.5 3.38 0.45 101 44.4 4.95 rk1r-4.5v rk1r-5v rk1r-6v rk1r-9v rk1r-12v rk1r-24v nominal voltage, v dc pick-up voltage, max. v dc drop-out voltage, min. v dc coil resistance, w ( 10%) nominal operating current, ma nominal operating power, mw maximum. allowable voltage, v dc (at 60 c 140 f ) ?single side stable type part no. rk1-l-3v 3 2.25 2.25 45 66.7 200 3.3 5 3.75 3.75 125 40 200 5.5 6 4.5 4.5 180 33.3 200 6.6 9 6.75 6.75 405 22.2 200 9.9 12 9 9 720 16.7 200 13.2 rk1-l-5v rk1-l-6v rk1-l-9v rk1-l-12v 24 18 18 2.25 3.75 4.5 6.75 9 18 2,880 8.3 200 26.4 rk1-l-24v rk1r-l-3v rk1-l-4.5v 4.5 3.38 3.38 101 44.4 200 4.95 rk1r-l-4.5v rk1r-l-5v rk1r-l-6v rk1r-l-9v rk1r-l-12v rk1r-l-24v nominal voltage, v dc set voltage, max. v dc reset voltage, max. v dc coil resistance, w ( 10%) nominal operating current, ma nominal operating power, mw maximum. allowable voltage, v dc (at 60 c 140 f ) ?1 coil latching type part no. rk1-l2-3v 3 2.25 22.5 133.3 400 3.3 5 3.75 62.5 80 400 5.5 6 4.5 90 66.7 400 6.6 9 6.75 202.5 44.4 400 9.9 12 9 360 33.3 400 13.2 rk1-l2-5v rk1-l2-6v rk1-l2-9v rk1-l2-12v 24 18 1,440 16.7 400 26.4 rk1-l2-24v rk1r-l2-3v 3.38 rk1-l2-4.5v 4.5 3.38 50.6 88.9 400 4.95 rk1r-l2-4.5v rk1r-l2-5v rk1r-l2-6v rk1r-l2-9v rk1r-l2-12v rk1r-l2-24v nominal voltage, v dc set voltage, max. v dc reset voltage, max. v dc coil resistance, w ( 10%) nominal operating current, ma nominal operating power, mw maximum. allowable voltage, v dc (at 60 c 140 f ) ?2 coil latching type 14 1 + 7 n.c. com n.o. 13 12 11 10 9 8 standard contact arrangement pc board pattern (copper-side view) schematic (bottom view) mm inch rk1 single side stable (deenergized condition) 7.62 .300 10-0.9 dia. 10-.035 dia. 2.54 .100 2.54 .100 (2 coil latching) tolerance: 0.1 .003 3-0.6 0.3 3-.024 .012 4-0.6 0.25 4-.024 .010 3-0.45 3-.018 stand-off (2 coil latching) general tolerance: 0.3 .012 14 6 + ? 17 reset com set 13 12 11 10 9 8 rk1-l2 2 coil latching (reset condition) 6 + ? 17 14 set com reset 13 12 11 10 9 8 rk1r-l2 14 + 1 7 set com reset 13 12 11 10 9 8 rk1r-l 14 1 + 7 n.o. com n.c. 13 12 11 10 9 8 r type contact arrangement rk1r 7.62 .300 9-0.9 dia. 9-.035 dia. 2.54 .100 2.54 .100 (single side stable and 1 coil latching) 2-0.6 0.3 2-.024 .012 4-0.6 0.25 4-.024 .010 3-0.45 3-.018 stand-off (single side stable and 1 coil latching) 14 + 1 7 reset com set 13 12 11 10 9 8 rk1-l 1 coil latching (reset condition) 9.1 .358 7.62 .300 3.5 .138 2.54 .100 0.6 .024 20.2 .795 11.2 .441 types ane coil data (at 20c 68f ) dimensions
rk 103 reference data 1.-(1) high frequency characteristics (impedance 75 w ) sample: rk1-12v measuring method: measured with hp network analyzer (hp8753c) ? insertion loss characteristics ? isolation characteristics ? v.s.w.r. characteristics 0.8 1.0 0 0.2 0.6 0.4 300khz 1.5ghz 3ghz com-nc com-no frequency insertion loss, db 80 100 0 20 60 40 300khz 1.5ghz 3ghz com-nc com-no frequency isolation, db 1.2 1.0 2.0 1.8 1.4 1.6 300khz 1.5ghz 3ghz com-no com-nc frequency v.s.w.r. 1.-(2) high frequency characteristics (impedance 50 w ) sample: rk1-5v measuring method: measured with hp network analyzer (hp8753c) ? insertion loss characteristics ? isolation characteristics ? v.s.w.r. characteristics 0.8 1.0 0 0.2 0.6 0.4 300khz 1.5ghz 3ghz com-nc com-no frequency insertion loss, db 80 100 0 20 60 40 300khz 1.5ghz 3ghz com-nc com-no frequency isolation, db 1.2 1.0 2.0 1.8 1.4 1.6 300khz 1.5ghz 3ghz com-no com-nc frequency v.s.w.r. 2. coil temperature rise sample: rk1-12v, rk1-l-12v, rk1-l2-12v no. of samples: n = 6 carrying current: 10 ma ambient temperature: 25c 77f 3.-(1) operate/release time (single side stable) sample: rk1-12v; no. of samples: n = 6 3.-(2) set/reset time (latching) sample: rk1-l-12v, rk1-l2-12v no. of samples: n = 12 0 20 40 60 80 100 80 100 130 150 rk1-l2-12v rk1-12v, rk1-l-12v voltage applied to coil, %v temperature rise, c 0 2 4 6 8 10 80 100 120 150 max. min. max. min. voltage applied to coil, %v operate/reset time, ms operate time release time 0 2 4 6 8 10 80 100 130 max. min. max. min. set time reset time voltage applied to the coil (%v) set/reset time, ms
rk 104 4.-(1) mechanical life test (single side stable) sample: rk1-12v; no. of samples: n = 12 4.-(2) mechanical life test (latching) sample: rk1-l2-12v no. of samples: n = 12 4.-(3) mechanical life test sample: rk1-12v no. of samples: n = 20 (20 2 contacts) 0 2 4 6 8 10 12 100 500 1,000 min. max. min. max. no. of operations, 10 4 pick-up/drop-out voltage, v pick-up voltage drop-out voltage 0 2 4 6 8 10 12 100 500 1,000 min. max. no. of operations, 10 4 set/reset voltage, v 0 50 100 150 200 250 300 50 100 500 1,000 min. max. no. of operations, 10 4 contact resistance, m w 5. electrical life test (0.01 a 24 v dc) sample: rk1-12v; no. of samples: n = 6 6. ambient temperature characteristics sample: rk1-12v; no. of samples: n = 6 7. contact resistance distribution (initial) sample: rk1-12v no. of samples: n = 50 (50 2 contacts) 0 2 4 6 8 10 12 10 20 30 min. max. min. max. no. of operations, 10 4 pick-up/drop-out voltage, v pick-up voltage drop-out voltage ?0 ?0 ?0 ? 0 20 68 40 20 ?0 ?0 rate of change, % ambient temperature, c f 40 104 60 140 80 176 pick-up voltage drop-out voltage 0 10 20 30 40 50 10 20 30 40 50 contact resistance, m w quantity 8.-(1) in?uence of adjacent mounting sample: rk1-12v; no. of sample: n = 10 8.-(2) in?uence of adjacent mounting sample: rk1-12v; no. of samples: n = 10 ?0 0 10 ?0 0 10 5 .197 10 .394 on on off off off condition on condition inter-relay distance, (mm, inch ) rate of change, % rate of change, % pick-up voltage drop-out voltage on on off off ?0 0 10 ?0 0 10 5 .197 10 .394 0 10 off condition inter-relay distance, (mm, inch ) rate of change, % rate of change, % on condition drop-out voltage pick-up voltage notes 1. soldering perform soldering under the conditions below. ? within 10 s at 260c 500f ? within 3 s at 350c 662f 2. latching relay in order to assure proper operating re- gardless of changes in the ambient usage temperature and usage conditions, nomi- nal operating voltage should be applied to the coil for more than 30 ms to set/reset the latching type relay. for cautions for use, see relay technical information (page 48 to 76). 9/1/2000 all rights reserved, ? copyright matsushita electric works, ltd. go to online catalog
|