Part Number Hot Search : 
MODELC 1N5461A H8S2111B P3020 TGP6336 GP30A MK1210 4013B
Product Description
Full Text Search
 

To Download 240U60D Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  document number: 93504 for technical ques tions, contact: ind-modules@vishay.com www.vishay.com revision: 28-may-08 1 standard recovery diodes (stud version), 320 a 240u(r).. series vishay high power products features ? diffused diode ? wide current range ? high voltage ratings up to 1200 v ? high surge current capabilities ? stud cathode and stud anode version ? hermetic metal case ? rohs compliant ? designed and qualified for industrial level typical applications ?welders ? power supplies ? machine tool controls ? high power drives ? medium traction applications ? battery charges ? freewheeling diodes electrical specifications product summary i f(av) 320 a do-205ab (do-9) rohs compliant major ratings and characteristics parameter test conditions values units i f(av) 320 a t c 100 c i f(rms) 500 a i fsm 50 hz 4500 a 60 hz 4700 i 2 t 50 hz 101 ka 2 s 60 hz 92 v rrm range 600 to 1200 v t j - 40 to 180 c voltage ratings type number voltage code v rrm , maximum repetitive peak reverse voltage v v rsm , maximum non-repetitive peak reverse voltage v i rrm maximum at t j = t j maximum ma 240u(r).. 60 600 700 15 80 800 900 100 1000 1100 120 1200 1300
www.vishay.com for technical questi ons, contact: ind-modules@vishay.com document number: 93504 2 revision: 28-may-08 240u(r).. series vishay high power products standard recovery diodes (stud version), 320 a note ? the table above shows the increment of thermal resistance r thjc when devices operate at diffe rent conduction angles than dc forward conduction parameter symbol test conditions values units maximum average forward current at case temperature i f(av) 180 conduction, half sine wave 320 a 100 c maximum rms forward current i f(rms) dc at 80 c case temperature 500 a maximum peak, one cycle forward, non-repetitive surge current i fsm t = 10 ms no voltage reapplied sinusoidal half wave, initial t j = t j maximum 4500 t = 8.3 ms 4700 t = 10 ms 100 % v rrm reapplied 3800 t = 8.3 ms 4000 maximum i 2 t for fusing i 2 t t = 10 ms no voltage reapplied 101 ka 2 s t = 8.3 ms 92 t = 10 ms 100 % v rrm reapplied 72 t = 8.3 ms 66 maximum i 2 t for fusing i 2 t t = 0.1 to 10 ms, no voltage reapplied 1010 ka 2 s slope resistance r f t j = t j maximum 0.6 m threshold voltage v f(t0) 0.83 v maximum forward voltage drop v fm i pk = 750 a, t j = 25 c, t p = 10 ms sinusoidal wave 1.33 thermal and mechanical specifications parameter symbol test conditions values units maximum junction operating and storage temperature range t j , t stg - 40 to 180 c maximum thermal resistance, junction to case r thjc dc operation 0.18 k/w maximum thermal resistance, case to heatsink r thcs mounting surface, smooth, flat and greased 0.8 maximum allowed mounting torque + 0 - 20 % not lubricated threads 37 (330) n m (lbf in) lubricated threads 28 (250) approximate weight 250 g case style see dimensions - link at the end of datasheet do-205ab (do-9 r thjc conduction conduction angle sinusoidal conduction recta ngular conduction test conditions units 180 0.019 0.015 t j = t j maximum k/w 120 0.023 0.025 90 0.030 0.034 60 0.045 0.047 30 0.076 0.076
document number: 93504 for technical ques tions, contact: ind-modules@vishay.com www.vishay.com revision: 28-may-08 3 240u(r).. series standard recovery diodes (stud version), 320 a vishay high power products fig. 1 - current ratings characteristics f ig. 2 - current ratings characteristics fig. 3 - forward powe r loss characteristics fig. 4 - forward powe r loss characteristics average forward current (a) maximum allowable case temperature (c) 80 90 100 110 120 130 140 150 160 170 180 0 50 100 150 200 250 300 350 30 60 90 120 180 conduction angle 240u(r) rthjc (dc) = 0.18 k/w average forward current (a) maximum allowable case temperature (c) 60 80 100 120 140 160 180 0 100 200 300 400 500 600 30 60 90 180 dc 120 240u(r) rthjc (dc) = 0.18 k/w conduction period average forward current (a) maximum allowable ambient temperature (c) 0 20406080100120140160180 rthsa = 0.1 k/w - de lta r 0.2 k/w 0.3 k/w 0.5 k/w 0.7 k/w 1 k/w 3 k/w 1.5 k/ w 0 50 100 150 200 250 300 350 400 450 0 50 100 150 200 250 300 35 0 rms limit conduction angle 180 120 90 60 30 240u(r).. tj = 180c average forward current (a) maximum allowable ambient temperature (c) 0 20406080100120140160180 rthsa = 0.1 k/w - delta r 0.2 k/w 0.3 k/w 0.5 k /w 0.7 k/ w 1 k/w 3 k/w 1.5 k/w 0 100 200 300 400 500 600 0 100 200 300 400 500 60 0 dc 180 120 90 60 30 rms limit conduction period 240u(r) series tj = 180c
www.vishay.com for technical questi ons, contact: ind-modules@vishay.com document number: 93504 4 revision: 28-may-08 240u(r).. series vishay high power products standard recovery diodes (stud version), 320 a fig. 5 - maximum non-repetitive surge current fig. 6 - maximum non-repetitive surge current fig. 7 - forward volt age drop characteristics fig. 8 - thermal impedance z thjc characteristic number of equal amplitude half cycle current pulses (n) peak half sine wave forward current (a) 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 11010 0 per junction at any rated load condition and with rated vrrm applied following surge. initial tj = 180c @ 60 hz 0.0083 s @ 50 hz 0.0100 s pulse train duration(s) peak half sine wave on-state current (a) 2000 2500 3000 3500 4000 4500 5000 0.01 0.1 1 maximum non repetitive surge current versus pulse train duration. control per junction of conduction may not be maintained. initial t j = 180c no voltage reapplied rated v rrm reapplied instantaneous forward voltage (v) instantaneous forward current (a) 10 100 1000 10000 0.5 1 1.5 2 2.5 3 3.5 tj = 25c tj = 180c square wave pulse duration (s) transient thermal impedance z thjc (k/w) 0.001 0.01 0.1 1 0.0001 0.001 0.01 0.1 1 10 steady state value rthjc per junction = 0.18 k/w dc operation)
document number: 93504 for technical ques tions, contact: ind-modules@vishay.com www.vishay.com revision: 28-may-08 5 240u(r).. series standard recovery diodes (stud version), 320 a vishay high power products ordering information table device code 5 13 24 6 24 0 u r 120 d 1 - 24 = essential part number 2 - 0 = standard device 3 - u = stud normal polarity (cathode to stud) 4 5 5 - voltage code x 10 = v rrm (see voltage ratings table) 6 - diffused diode note = for metric device m16 x 1.5 contact factory - none = stud normal polarity (cathode to stud) r = stud reverse polarity (anode to stud) links to related documents dimensions http://www.vishay.com/doc?95317
document number: 95317 for tec hnical questions, contact: indmodules@vishay.com www.vishay.com revision: 02-jul-08 1 do-205ab (do-9) for 240u(r) series outline dimensions vishay semiconductors dimensions in millimeters (inches) note (1) for metric device m16 x 1.5 contact factory 190 (7.48) max. 19.2 (0.76) max. ? 8.9 (0.35) ? 8.4 (0.33) 53.3 (2.1) max. 3.18 (0.12) max. unthreaded portion 10 (0.39) max. 3/4"-16unf-2a (1) 21 (0.82) max. sw 32 ? 27.9 (1.1) max. 23 (0.91) plone min. 4.2 (0.17) max.
legal disclaimer notice www.vishay.com vishay revision: 12-mar-12 1 document number: 91000 disclaimer all product, product specifications and data are subject to change without notice to improve reliability, function or design or otherwise. vishay intertechnology, inc., its affiliates, agents, and employee s, and all persons acting on it s or their behalf (collectivel y, vishay), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any o ther disclosure relating to any product. vishay makes no warranty, repres entation or guarantee regarding the suitabilit y of the products for any particular purpose or the continuing production of any product. to the maximum extent permitted by applicable law, vi shay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation specia l, consequential or incidental damages, and (iii) any and all i mplied warranties, including warra nties of fitness for particular purpose, non-infringement and merchantability. statements regarding the suitability of products for certain type s of applications are based on vishays knowledge of typical requirements that are often placed on vishay products in generic applications. such statements are not binding statements about the suitability of products for a particular application. it is the customers responsib ility to validate that a particu lar product with the properties descri bed in the product specification is suitable fo r use in a particular application. parameters provided in datasheets and/or specification s may vary in different applications an d performance may vary over time. all operating parameters, including typical pa rameters, must be validated for each customer application by the customers technical experts. product specifications do not expand or otherwise modify vish ays terms and condit ions of purchase, including but not limited to the warranty expressed therein. except as expressly indicate d in writing, vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the vi shay product could result in personal injury or death. customers using or selling vishay products no t expressly indicated for use in such applications do so at their own risk and agr ee to fully indemnify and hold vishay and it s distributors harmless from and against an y and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale , including attorneys fees, even if such claim alleges that vis hay or its distributor was negligent regarding th e design or manufacture of the part. please contact authorized vishay personnel t o obtain written terms and conditions regardin g products designed for such applications. no license, express or implied, by estoppel or otherwise, to any intellectual prope rty rights is granted by this document or by any conduct of vishay. product names and markings noted herein may be trad emarks of their respective owners. material category policy vishay intertechnology, inc. hereby certi fies that all its products that are id entified as rohs-compliant fulfill the definitions and restrictions defined under directive 2011/65/eu of the euro pean parliament and of the council of june 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (eee) - recast, unless otherwis e specified as non-compliant. please note that some vishay documentation may still make reference to rohs directive 2002/95/ ec. we confirm that all the products identified as being compliant to directive 2002 /95/ec conform to directive 2011/65/eu.


▲Up To Search▲   

 
Price & Availability of 240U60D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .