features ? 0.18 in 2 board space ? 5, 12, 24 and 48 vdc inputs ? 80% efficiency ? 1000 vdc isolation ? 15 watts per in 3 ? industry standard pinouts dc/dc converters ia series 1 watt electrical specifications all specifications typical at nominal line, full load and 25? input voltage range 10% input reflected noise (20mhz bw) 100mv p-p max. output voltage accuracy 5% line regulation 1.2%/1% of vin load regulation (20% to 100% load) 10% output ripple and noise (20 mhz bw) 75mv p-p max. efficiency at full load 9v, 12v and 15v outputs 80% typical efficiency at full load 3.3v and 5v outputs 70% typical short circuit protection 1 second max. input output isolation 1000vdc min. temperature coefficient 0.03% per ? max operating temperature range -40? to 85? storage temperature range -55? to 125? 260 hopping brook road holliston, massachusetts 01746 tel. (508) 429-4440 fax (800) 226-2100 http://www.intlpower.com specifications subject to change. unit requires 10mm of air space. shown actual size models chart output output part numbers voltage(s) current(s) 5vdc input 12vdc input 24vdc input 48vdc input 3.3vdc 150ma ia0503 ia1203 ia2403 ia4803 5vdc 100ma ia0505 ia1205 ia2405 ia4805 9vdc 55ma ia0509 ia1209 ia2409 ia4809 12vdc 42ma ia0512 ia1212 ia2412 ia4812 15vdc 33ma ia0515 ia1215 ia2415 ia4815 add suffix ??for single-in-line package, suffix ??for dual-in-line package.
mechanical specifications single-in-line package dual-in-line package derating curve pin connections pins .01 x .02 inches * 0.280 max for 48vdc input models 0.240 max* 0.780 max 0.015 0.400 max 0.120 min 0.100 0.045 0.010 max 0.500 0.400 max 0.800 max 0.110 min 0.310 max 0.300 0.010 0.300 typ 0.600 0.18 bottom single-in-line package dual-in-line package (top view) 12 456 vcc gnd -v 0v +v vcc gnd nc -v 0v +v 17 14 11 9 8 1.5 1.25 1.0 .75 .5 0 -40 0 25 50 75 100 85 safe operating area s a f e o p e r a t i n g a r e a safe operating area ambient temperature c output power (watts) temperature derating graph
|