1/97 n/al. 8.300. 300.01 b07 miniature series 07 general purpose filter/regulator 1/8 " and 1/4 " port sizes l compact design l full flow gauge ports l low torque, non-rising adjusting knob l snap action knob locks pressure setting when pushed in l standard relieving models allow reduction of outlet pressure even when the system is dead-ended l protects air operated devices by removing liquid and solids contaminants l screw-on bowl reduces maintenance time l can be disassembled without the use of tools or removal from the air line ordering information see ordering information on the following pages. technical data fluid: compressed air maximum pressure: transparent bowl: 10 bar (145 psig) metal bowl: 17 bar (250 psig) operating temperature:* transparent bowl: -20 to +50? (0 to +125?) metal bowl: -20 to +65? (0 to +150?) * air supply must be dry enough to avoid ice formation at temperatures below +2? (+35?) particle removal: 5 ? or 40 ? filter element air quality: within iso 8573-1, class 3 and class 5 (particulates) typical flow at 10 bar (100 psig) inlet pressure, 6,3 bar (90 psig) set pressure and a droop of 1 bar (15 psig) from set: 1/8" ports: 6 dm 3 /s (13 scfm) with 5 ? element 1/4" ports: 6 dm 3 /s (13 scfm) with 5 ? element nominal bowl size: 31 ml (1 oz) gauge ports: 1/8" ptf with ptf main ports 1/8" iso rc with iso rc main ports 1/8" iso rc with iso g main ports drain connection: 1/8" pipe automatic drain operation: spitter type drain operates momentarily when a rapid change in air flow occurs or when the supply pressure is reduced. materials: body: zinc bonnet: acetal valve: brass/nitrile valve seat: acetal bowl: transparent: polycarbonate metal: zinc element: sintered polypropylene elastomers: nitrile iso symbols automatic drain relieving manual drain relieving our policy is one of continuous research and development. we reserve the right to amend, without notice, the specifications given in this document. automatic drain non-relieving manual drain non-relieving
n/al. 8.300. 300.0 2 1/97 b07 our policy is one of continuous research and development. we reserve the right to amend, without notice, the specifications given in this document. alternative models - h h h h h h - 0 h b 7 threads substitute ptf a iso rc taper b iso g parallel g drain substitute automatic a manual m port size substitute 1/8" 1 1/4" 2 element substitute 5 m 1 40 m 3 bowl relief type gauge substitute transparent relieving without 01 transparent non-relieving without 03 metal relieving without 33 metal non-relieving without 35 metal relieving without 05** metal non-relieving without 07** inlet pressure: 10 bar g (145 psig) flow characteristics 0 2 4 6 8 10 dm 3 /s air flow 0 4 8 12 16 20 24 scfm 8 6 4 2 0 outlet pressure bar g 100 80 60 40 20 0 psig outlet pressure adjustment ranges* substitute 0.1 to 0.7 bar (1 to 10 psig) a 0.3 to 3.5 bar (5 to 50 psig) e 0.3 to 7 bar (5 to 100 psig) k 0.3 to 10 bar (5 to 145 psig) m** * outlet pressure can be adjusted to pressures in excess of, and less than, those specified. do not use these units to control pressures outside of the specified ranges. ** when specifying 10 bar (145 psig) unit, eg. b07-2 05 -a3 m g, also note correct code at 5th and 6th digits. o r dering inf ormation. models listed include iso g threads, transparent bowl, relieving diaphragm, automatic drain, 40 m element, 0,3 to 7 bar (5 to 100 psig) outlet pressure adjustment range* . port size model number flow? dm 3 /s (scfm) weight kg (lbs) g1/8 B07-101-A3KG 6,2 dm 3 /s (13) 0,26 (0.57) g1/4 b07-201-a3kg 6,5 dm 3 /s (14) 0,26 (0.57) ? typical flow with 7 bar (100 psig) inlet pressure, 6,3 bar (90 psig) set pressure and a 1 bar (14.5 psig) droop from set. wall mounting bracket and tamper resistant 40 mm panel nut for p1h unit panel nut field modification pressure gauge r1/8 connection 1/8"ptf connection plastic: 18-025-003 plastic: 2962-89 knob and screw: 18-001-092 2 bar (30 psig): 18-013-214 metal: 2962-04 screw only: 6097-08 4 bar (60 psig): 18-013-990 18-013-211 10 bar (150 psig): 18-013-989 18-013-212 25 bar (350 psig): 18-013-908 accessories t ypical p erf ormance characteristics port size: 1/4" range: 0,3 to 7 bar (5 to 100 psi) e lement: 40 m
1/97 n/al. 8.300. 300.0 3 b07 our policy is one of continuous research and development. we reserve the right to amend, without notice, the specifications given in this document. ser vice kits item type part number service kit relieving models, 40 m element 3820-14 non-relieving models, 40 m element 3820-13 replacement drains manual 773-03 automatic 3654-02 item part number all models 18-025-003 brac ket mounting use 3mm (1/8") screws to mount bracket to wall. brac ket kit ref erence 38 (1.49) 46 (1.81) 6 (0.22) 38 (1.50) 7 (0.29) 24 (0.93) 63 (2.47) 28 to 44 (1.09 to 1.73) automatic drain manual drain 54 (2.13) 41 (1.63) 38 (1.50) 38 (1.50) 214 (8.41)* 28 (1.12) 68 (2.67) 164 (6.44) 28 (1.1) 210 (8.26)* 28 (1.12) 68 (2.67) 160 (6.29) 28 (1.1) dimensions mm (inc hes) service kit includes slip ring, diaphragm, valve seat with o-ring, valve, valve spring, element, element gasket, and bowl o-ring. panel mounting hole diameter 30 mm (1.19 " ) panel thickness 0 to 6 mm (0 to 0.25 " ) * minimum clearance to remove bowl
b07 n/al. 8.300. 300.0 4 1/97 our policy is one of continuous research and development. we reserve the right to amend, without notice, the specifications given in this document. w arning these products are intended for use in industrial compressed air systems only. do not use these products where pressures and temperatures can exceed those listed under ?echnical data? before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult norgren. through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. the system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. system designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. system designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. water vapor will pass through these units and will condense into liquid if air temperature drops in the downstream system. install an air dryer if water condensation could have a detrimental effect on the application.
|