  Datasheet File OCR Text:
  oct 30, 2006 revised to nov 10, 2006 page 1 of 6 www.power-one.com FCP600-48 ac-dc front end data sheet 48v output, 600 watts applications ? telecommunications equipment advance product release features ? rohs lead-free solder and lead-solder-exempted products are available ? wide input voltage range 85-264 vac ? two outputs (one high current output) ? low conducted and radiated emi (en 55022 class b) ? ul recognized to ul 60950/csa 22.2 no. 60950-00, and tuv approved to en 60950-1 ? high density design 4? x 1.65? x 8.5? cassette ? highly-efficient topology ? 100 khz i 2 c interface ? overtemperature, output overvoltage, and output overcurrent protection ? supervisory signaling ? included oring diode for true redundant operation description the FCP600-48 is a highly-efficient ac-dc power suppl y with one high current output and an auxiliary standby output, which can be used in a wide range of applications. passive current share along with internal oring diodes allow this unit to be also used in redundant, hot-swap applications. the FCP600-48 meets international safety standards and displays the ce mark for the low voltage directive. model selection output 1 standby output model input voltage vac v o nom vdc i o max adc v o nom vdc i o max adc rated power w FCP600-48 85-264 48 13 3.35 2.5 632 ordering information options suffixes to add to part number rohs lead solder exemption no rohs suffix character required. rohs compliant for all 6 substances add "g " as the last character of the part number.
oct 30, 2006 revised to nov 10, 2006 page 2 of 6 www.power-one.com FCP600-48 ac-dc front end data sheet 48v output, 600 watts absolute maximum ratings stresses in excess of the absolute maximum ratings ma y cause performance degradation, adversely effect long- term reliability, and cause permanent damage to the converter. parameter conditions/description min max units input voltage continuous transient, 60 ms 264 300 vac vac operating temperature ambient v i min - v i max , i o nom , cooling by internal fan 0 55 c storage temperature non- operational -40 85 c environmental, mechanical, & reliability specifications all specifications apply over specified input voltage, output load and temperature ra nge, unless otherwise noted. parameter conditions/descrip tion min nom max units operating humidity relative humidity, non-condensing 10 90 % storage humidity relative humidity, non-condensing 5 95 % shock iec/en 60068-2-27, 11 ms 30 g n sinusoidal vibration iec/en 60068-2-6 2-8 hz 8-200 hz 200-500 hz 7.5 2 4 mil g n g n mtbf mil-hdbk-217f notice 2, g b , 25 c tbd kh isolation specifications the electric strength test is performed in the factory as routine test in accordance with en 550116, iec/en 60950, and ul 1950 and should not be repeated in the field. powe r-one will not honor any warranty claims resulting from electric strength field tests. parameter conditions/descrip tion min nom max units insulation safety rating input/case input/output output/case basic reinforced functional electric strength test voltage input/case input/output output/case 2.121 3.6 0.5 kvdc kvdc kvdc
oct 30, 2006 revised to nov 10, 2006 page 3 of 6 www.power-one.com FCP600-48 ac-dc front end data sheet 48v output, 600 watts emc specifications all specifications apply over specified input voltage, output load and temperature ra nge, unless otherwise noted. parameter description criterion electrostatic discharge iec/en 61000-4-2, level 4 (contact/air) 8/15 kv, criterion b electromagnetic field iec/en 61000- 4-3, level 3 10 v/m, criterion a electr. fast transients / burst iec/en 61000-4-4, level 3 (direct/capacitive) 2/1 kv, criterion b surge iec/en 61000-4-5, level 3 (l/l, l/c) 1/2 kv, criterion b voltage dips and interruptions iec/en 61000-4-11 criterion b rf conducted immunity iec/en 61000-4-6 10 vac, am 80%, 1 khz, criterion a emissions radiated/conducted cispr 22/en 55022/en 61204 class b harmonics iec/en 61000-3-2 class b voltage fluctuation and flicker iec/en 61000-3-3 pass input specifications all specifications apply over specified input voltage, output load and temperature ra nge, unless otherwise noted. parameter conditions/descrip tion min nom max units input voltage 85 115/230 264 vac turn-on input voltage ramping up 70 - 85 vac turn-off input voltage ramping down 70 - 85 vac input frequency 47 50/60 63 hz inrush current limitation 115/230 vac 20 a power factor v i nom , i o nom 0.96 efficiency v i = 230 vac, i o nom 88 % output specifications all specifications apply over specified input voltage, output load and temperature range unless otherwise noted. parameter conditions/descrip tion min nom max units output voltage setpoint accuracy v i = 230 vac, i o1 @ 6.5 adc, t c = 25 c -0.5 0.5. % v o nom output current v1 standby output 0 0 13 2.5 14.3 2.75 adc adc static line regulation v1 v i min - v i max , v i nom , 0-100% i o nom -0.5 0.5 % v o nom static load regulation v1 (droop characteristic) v i min - v i max , v i nom , 0-100% i o nom -250 mv/a hold-up time starting at v i = 230 vac, p o nom 20 ms dynamic load regulation load change = 33%, di o /dt = 2a/ s voltage deviation recovery time -2 2 400 % v o nom s start-up time v i nom , i o nom 1 s output voltage ripple and noise v i nom , i o nom , 20 mhz bandwidth 120 mvpp
oct 30, 2006 revised to nov 10, 2006 page 4 of 6 www.power-one.com FCP600-48 ac-dc front end data sheet 48v output, 600 watts protection all specifications apply over specified input voltage, output load and temperature ra nge, unless otherwise noted. parameter conditions/descrip tion min nom max units input fuse not user accessible 12.5 at input transient protection with varistor output no-load and short circuit proof short circuit proof overload (latch style) 110 130 % i o nom % i o nom % i o nom overvoltage protection latch style 110 115 % v o nom overtemperature protection automatic power shutdown at t c = tbd control all specifications apply over specified input voltage, output load and temperature ra nge, unless otherwise noted. parameter conditions/description i 2 c digital bus reports information and monitors alarm functions ps seated signal contact closure to gnd ps remote shutdown ttl compatible signal, inhibited at high or ttl ?1? ac fail pre-warning (i 2 c & oc)* supervisory ac input voltage; pre-warning time >6 ms dc fail (i 2 c & oc)* supervisory under- and overvoltage pre-oring diode of v1 temperature warning (i 2 c & oc)* indicates if unit is operating no rmally or in overtemperature, pre-warning time >10 ms fan ok (i 2 c & oc)* indicates if fan is operating or has failed current share droop load characteristic for v1 status indication leds: dc ok (green), ac ok (green) * signal providing by i 2 c interface (i 2 c) or by open collector (oc) features all specifications apply over specified input voltage, output load and temperature ra nge, unless otherwise noted. parameter conditions/description fan speed control 2 fan speed levels depending on internal heat sink temperature fan speed level and temperature information available on i 2 c digital bus c supply voltage in-/output (pin 10) if unit is operating: 5 to 7v is provided at pin 10. if unit is not operating, pin 10 is input from a parallel connected unit for c supply.
oct 30, 2006 revised to nov 10, 2006 page 5 of 6 www.power-one.com FCP600-48 ac-dc front end data sheet 48v output, 600 watts characteristic curves: 86 122 158 194 230 266 -5 55 82 83 84 85 86 87 88 89 90 91 eta [%] vi [v] temp [c] figure 1. efficiency vs. input voltage and ambient temperature, i o = i o nom nuclear and medical applications - power-one products are not de signed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous env ironments, or nuclear control systems without the express wr itten consent of the respecti ve divisional president of power-one, inc. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change dependi ng on the date manufactured. specifications are subject to change without notice.
oct 30, 2006 revised to nov 10, 2006 page 6 of 6 www.power-one.com FCP600-48 ac-dc front end data sheet 48v output, 600 watts mechanical data mechanical data (h, w, d) 4? (101.6mm) x 1.65? (41.9mm) x 8.5? (215.9mm) output connector descriptions rear view connector: molex (15-06-0241) output connector description pin location reference name 48v output 4,5,6,16,17,18 vo1 48v output rtn 1,2, 3,13,14,15 vo1 rtn ac-fail, dc-fail, temp.- fail 9 pf power supply present signal 23 pspres serial data line 11 sda serial clock line 12 scl address input line a0 21 a0 5 to 7v 10 c supply voltage bus fan fail 24 ff ps enable 22 psen 3.35v standby rtn 7 vo2 rtn / logic ground / 5 to 7v rtn 3.35v standby 19 vo2


▲Up To Search▲   

 
Price & Availability of FCP600-48

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X