  agilent N7786B polarization synthesizer data sheet introduction the agilent N7786B contains a high-speed lithium- niobate based polarization controller and a polarization analyzer plus a microcontroller-based driving circuitry. this unit can operate in various modes: as a polarization stabilizer , it provides a stable output state of polarization (sop) even with fluctuations and drifts of the input sop. the stabilized output signal is guided in a standard single-mode fiber (smf). the out- put sop can be defined in the following ways: set-and-forget: when the front button is pushed, the current sop is stored and maintained, even if polarization changes occur on the instrument input. defined stokes : the target output sop can be defined by the user using the stokes parameters. as a synchronous scrambler , the device switches the sop of the output signal in a random (pseudo) way with a cycling speed of up to 100 ksops/s. sop switching occurs within a few microseconds. an electrical trigger input can be used to synchronize the scrambler with external events. as an sop switch , the N7786B cycles through a sequence of sops with a speed of more than 40 khz, which corresponds to a cycle time of less than 25 microseconds. the sequence of sops can easily be defined by the user using stokes coefficients. as a traditional scrambler , the N7786B varies the output sop in a random way. full coverage of the poincar sphere is achieved within a few ms. as a polarization analyzer , the instrument provides truly high-speed capabilities: more than 500k samples can be taken with a sample rate of up to 1 megasample per second. the unit does not contain any moving parts, and therefore is robust and withstands even rough environmental conditions. all above-mentioned applications of the N7786B are supported by agilent pc software that comes with this instrument. various instrument drivers and connectivity to external applications are provided through a dll interface. examples are included. figure 1. N7786B bench-top instrument
2 agilent N7786B polarization synthesizer data sheet figure 2. instrument setup applications transmission system test: polarization sensitivity analysis on link / transmission quality recirculating loop experiments: loop-synchronous polarization scrambling interferometry: polarization stabilization to maximize contrast ratio polarization analysis agilent N7786B instrument setup and application examples key bene? ts comprehensive polarization stabilization/control switching capabilities reset-free/endless operation covers entire range from 1.3 m window up to the l-band compact size standalone operation robust, no moving parts the instrument setup is shown in figure 2. a dsp-based electronics controls the polarization analyzer as well as the polarization controller. the sop can be stabilized by means of a closed-loop operation of the dsp. application examples the transmission quality of links is known to depend on the state of polarization (sop) of the launching signal. the N7786B is well suited to launch the modulated signal with prede? ned sops into the link. this allows probing for a range of sops on the poincar sphere to get information about particular polarization issues of a link. the results obtained in re-circulating loop experiments depend heavily on the pmd and pdl pr operties of the l oop. loop synchronous polarization scrambling schemes have proven to be necessary for generating results comparable to deployed systems. the N7786B is ideally suited to provide the synchronous scrambling capability in such experiments. fiber-optic-based interferometers or coherent receiver schemes need polarization stabilization in order to avoid fading problems of the interference signal. these fading effects are caused by orthogonally polarized fractions of the light. the N7786B allows elimination of such effects by alignment of the signal polarization. figure 3. transmission experiments figure 4. recirculating loop figure 5. interferometry/coherent detection input port output port smf smf usb gpib trigger in trigger out polarization controller polarization analysis power in microcontroller board tx ampli?er ampli?er ampli?er ampli?er bert eye-diagram n7786 b polari zation synthesi zer rx dcf dcf dcf dcf n7785b synchronous scrambler computer trigger tx unit ampli?er switch rx unit fiber loop pol contr laser interferogram N7786B polarization synthesizer sensor
3 agilent N7786B polarization synthesizer data sheet table 1: speci? cations 1 N7786B polarization synthesizer wavelength speci? cation wavelength range 1270 nm ... 1375 nm, 1460 nm ... 1620 nm (opt 400, o/c/l-band) 1460 nm ... 1620 nm (opt 500, c/l-band) operating wavelength range 2) 1260 nm ... 1640 nm polarization control and stabilization sop switching time (non deterministic) < 10 s sop cycling time 6) < 25 s remaining sop error after deterministic sop setting (typical) 7) < 3 at input sop movement rate of 1.2 rad/s < 6.5 at input sop movement rate of 40 rad/s polarization analysis sop uncertainty (typical) 1,5 dop uncertainty 2,0% dop uncertainty after user 3),5) calibration (typical) 0,5% optical power measurement relative power uncertainty 3) c/l-band: 140 mdb ( 120 mdb typ.) o-band: 160 mdb ( 140 mdb typ.) input power range -38 dbm ... +19 dbm optical power insertion loss < 4.0 db (< 3.5 db, typ) pdl (typical) < 0.2 db maximum safe input power 20 dbm 1) ambient temperature change max. 0.5c since normalization. specification valid on day of calibration. 2) sop/dop measurements are possible outside the specification wavelength range if the user performs a manual calibration. 3) input power > -20 dbm. 4) dop > 95%. 5) user calibration requires a source with a known dop. 6) the instrument adaptively finds the polarization controller settings to let the sop cycle through user-defined polarization states (closed loop operation). after having found these settings, the sop can cycle through the polarization states in open loop operation. 7) this value is defined to be 5 times the standard deviation of the angular sop error on the poincar sphere. valid if con- troller is turned on. power at instrument input > -10 dbm.
www.agilent.com/? nd/emailupdates get the latest information on the products and applications you select. www.agilent.com/? nd/agilentdirect quickly choose and use your test equipment solutions with con? dence. agilent email updates agilent direc t www.agilent.com for more information on agilent technologies products, applications or services, please contact your local agilent office. the complete list is available at: www.agilent.com/find/contactus americas canada (877) 894-4414 latin america 305 269 7500 united states (800) 829-4444 asia paci? c australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 112 929 japan 81 426 56 7832 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 thailand 1 800 226 008 europe austria 0820 87 44 11 belgium 32 (0) 2 404 93 40 denmark 45 70 13 15 15 finland 358 (0) 10 855 2100 france 0825 010 700 germany 01805 24 6333* *0.14/minute ireland 1890 924 204 italy 39 02 92 60 8 484 netherlands 31 (0) 20 547 2111 spain 34 (91) 631 3300 sweden 0200-88 22 55 switzerland (french) 41 (21) 8113811(option 2) switzerland (german) 0800 80 53 53 (opt ion 1) united kingdom 44 (0) 118 9276201 other european countries: www.agilent.com/find/contactus revised: may 7, 2007 product speci? cations and descriptions in this document subject to change without notice. ? agilent technologies, inc. 2008 printed in usa, april 30, 2008 5989-8115en remove all doubt our repair and calibration services will get your equipment back to you, performing like new, when promised. you will get full value out of your agilent equipment throughout its lifetime. your equipment will be serviced by agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. you will always have the utmost con? dence in your measurements. agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. for more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt