 Limit Switches XCKML--General Specifications and Complete Devices
www.SquareD.com
For the most up-to-date information
www..com
2 N.O. and 2 N.C. Direct Opening Snap Action Contacts Rated Power Conforms to IEC 947-5-1 Duty Categories AC15 and DC13.
XCKML is a general duty limit switch, larger than the XCKL, for applications such as machine tools, material handling, and other applications where electrical redundancy and contact state signaling are required. Key features include: * 2 normally closed direct opening and two normally open snap action contacts available in 4 head styles * Direct opening contacts standard: snap action 2-pole (isolated N.O. + N.C.) or slow-make-slow-break 2-pole (isolated N.O. + N.C.) * 4 position indexing rotary head (field convertible) * Captive screws and gaskets * Captive saddle clamp terminals * Feature FINGERSAFE(R) contact block * Lever operated--positive lever to shaft positioning to ensure the direct opening feature. Direct opening contacts meet IEC 947-5-1 requirements for positive opening contacts. * Plunger operated: top rod, top roller * Metal type, IP66 * Complete switches with 3 cable entries * Tapped for 13 mm cable gland, DE9RA1212 adapter to 12" NPT included UL Listed CSA Certified, IEC, VDE, CENELEC and other international approvals, CE Characteristics
Products Machine assemblies Protective treatment Ambient air temperature to vibration Resistance to shocks Electric shock protection Degree of protection Minimum force of for tripping torque for positive opening Maximum actuation speed Switch actuation Repeat accuracy Conforming to standards Rated operational characteristics Rated insulation voltage Rated impulse withstand voltage Positive operation Short-circuit protection Cable entry Cabling IEC 947-5-1, EN 60 947-5-1 IEC 204-1, EN 60 204-1, NF C 79-130 Standard version: "TC" Operation: -25 to +70 C 25 gn (10 to 500 Hz) conforming to IEC 68-2-6 50 gn conforming to IEC 68-2-27 Class I conforming to IEC 536 and NF C 20-030 IP66 conforming to IEC 529; IP65 conforming to NF C 20-010 15 N 12 N 8N 0.2 N.m 60 N 50 N 50 N 0.5 N.m 0.5 m/s 0.5 m/s 1.5 m/s 1.5 m/s On end By 30 cam 0.1 mm on the tripping points ~ AC-15; A300 or Ue = 240 V, le = 3 A (for make and break ratings see XCKL page 19-20) DC-13; Q300 or Ue--250 V, le = 0.27 A conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1 Ui = 500 V degree of pollution 3 conforming to IEC 947-1 U imp = 6 kV conforming to IEC 947-1, IEC 664 N.C. contacts with direct opening operation conforming to IEC 947-5-1 Appendix K, EN 60 947-5-1 10 A cartridge fuse gG (gl) 3 tapped entries for 13 mm cable glands conforming to NFC 68-300 (DIN Pg 13.5). Clamping capacity 9 to 12 mm. Screw and captive cable clamp terminals. Clamp capacity: minimum 1 x 0.34 mm2, maximum: 2 x 1.5 mm2 or 1 x 2.5 mm2 depending on contact. Tightening torque: minimum 0.8 Nm, maximum 1.2 Nm
LIMIT SWITCHES
Note:Heads use the same lever as those used on the XCKL line. For direct opening operation use rigid operators. For characteristics of XESP*** and XENP*** contact blocks, please refer to our Limit Switch catalog 9007CT9701. (Only the heads shown below are UL Listed.)
19
Selection Table
Type of Operating Head Plunger Rotary
Type of operator
Metal end plunger References ( N.C. contact with direct opening operation)
13 21
13 21
Steel roller plunger
Thermoplastic roller lever plunger. Horizontal actuation in 1 direction
Thermoplastic roller lever a
Two contact blocks, 2-pole 1 N.C. + 1 N.O. snap action Two contact blocks, 2-pole 1 N.C. + 1 N.O. break before make, slow break Weight (kg)
14
22
A
14
B
3 entries 13 mm
13 21
13 21
22
XCKML110 $88.
XCKML102 $108.
XCKML121 $108.
XCKML115 $91.
22
14
A
14
B
3 entries 13 mm 0.400 0.405 0.450 0.430
a Adjustable throughout 360 in 5 steps, or in 90 steps by reversing the notched washer. b Do not replace head. Order complete unit.
22
XCKML510 $88.
XCKML502 $108.
XCKML521 $108.
XCKML515 $91.
For additional information, reference Catalog #9006CT0101.
19-22
9/8/03
T
Discount Schedule
(c) 2003 Schneider Electric All Rights Reserved 9/8/03


▲Up To Search▲   

 
Price & Availability of IEC947-5-1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X