|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Fiber-Optic Accessories Various Accessories Expand the Usefulness of the Fiber-Optic Cables Lenses extend sensing distances Side-view attachments provide space savings Flexible stainless steel tubes protect plastic fibers from mechanical damage Thin fiber adapters as replacement Splices for 2.2 mm fiber can be used to repair cut fiber E39 Ordering Information ATTACHMENTS Description Focusing lens pair (use with E32-TC50/200/500/1000, E32-T11(L), E32-TC200C, E32-T61) Side-view reflector pair Convergent beam conversion kit (to fit fibers that accept E39-F1 lenses) Pinpoint focusing lens (for E32-D32) Side-view diffuse reflective conversion kit (for through-beam fibers) Part number E39-F1 E39-F2 E39-F3 E39-F3A E39-F5 PROTECTIVE STAINLESS STEEL FLEXIBLE TUBES FOR PLASTIC FIBERS Description E32-DC200E, E32-DC200F(4), E32-D21, E32-D21L Single tubes Appearance Length (L) 0.5 m 1m 0.5 m 1m 0.5 m Pairs Part number E39-F32A5 E39-F32A E39-F32D5 E39-F32D E39-F32B5 E39-F32B E39-F32C5 E39-F32C E32-DC200, E32-DC200B(4), E32-CC200, E32-D11 E32-D11L, E32-D51 E32-TC200E, E32-TC200F(4), E32-T21, E32-T12L E32-TC200, E32-TC200B(4), E32-T11, E32-T11L, E32-T51L 1m 0.5 m 1m ADAPTERS/REPAIR PARTS Description Thin fiber adapter (1.0 mm to 2.2 mm dia.) Splice for 2.2 mm dia. fiber (except E32-T51/E32-D51) Fiber cutting tool (supplied with each trimmable plastic fiber optic cable) Fiber probe bending tool Mounting bracket replacement for E32-T16 (order two) Part number E39-F9 E39-F10 E39-F4 E39-F11 E39-L4 E39 E39 Dimensions Unit: mm (inch) ATTACHMENTS E39-F1 Lens kit (pair) E39-F2 Side-view attachment (pair) Note: One set includes two units. Note: One set includes two units. E39-F3 Convergent beam conversion kit M3 toothed washers Two, 4 dia. Two, M3 x 3 Slotted head machine screws 18 6.4 12 3.6 3 8.5 Two, 3.2 +0.2 0 dia. 8 0.2 20.7 6.4 6.5 M3 x 6 Angle fixing screw E39-F5 Side-view diffuse reflective conversion kit E39-F3A Reflective unit lens (Allen wrench included) PROTECTIVE STAINLESS STEEL TUBES E39-F32A, E39-F32A5 E39-F32B, E39-F32B5 Note: 1. L is as follows: E39-F32A and E39-F32B: 1,000 E39-F32A5, E39-F32B5: 500 2. These are sold as pairs. 2 E39 Unit: mm (inch) E39 E39-F32C, E39-F32C5 Note: 1. L is as follows: E39-F32C: 1,000 E39-F32C5: 500 2. These are sold as single pairs. E39-F32D, E39-F32D5 Note: 1. L is as follows: E39-F32D: 1,000 E39-F32D5: 500 2. These are sold as single tubes. ADAPTERS/REPAIR PARTS E39-F4 Fiber cutter E39-F11 Bending tool E39-F9 Attachment for thin fiber E39-F10 Fiber connector 3 E39 E39 Installation INSTALLING ACCESSORIES E39-F1 Lens Kit This pair of lenses increases the sensing distance of selected fiber-optic cables. To install, screw each lens onto the threaded tip of each sensing head. Amplifer Part number E3X-A Sensing distance with fiber-optic cables Fiber-optic E32-T11 cable w/ lens w/o lens E3X-DA w/ lens w/o lens E3X-F w/ lens w/o lens E3X-H w/ lens w/o lens E3X-NH w/ lens w/o lens E3X-NHB w/ lens w/o lens E3X-NM w/ lens w/o lens E3X-NT w/ lens w/o lens E3X-NV w/ lens w/o lens E3X-NVG w/ lens w/o lens E3X-VG w/ lens w/o lens 1m (3.3 ft) 180 mm (7.1 in) 4m (13.1 ft) 850 mm (33.5 in) 400 mm (15.8 in) 80 mm (3.2 in) 2m (6.6 ft) 360 mm (14.2 in) 2m (6.6 ft) 360 mm (14.2 in) 250 mm (9.8 in) 90 mm (3.5 in) 1.3 m (4.3 ft) 240 mm (9.4 in) 1.4 m (4.6 ft) 260 mm (10.2 in) 1.4 m (4.6 ft) 260 mm (10.2 in) 120 mm (4.7 in) 10 mm (0.4 in) 120 mm (4.7 in) 10 mm (0.4 in) E32-T11L 1m (3.3 ft) 350 mm (13.8 in) 4m (13.1 ft) 1.66 m (5.5 ft) 550 mm (21.7 in) 150 mm (5.9 in) 2m (6.6 ft) 700 mm (27.6 in) 2m (6.6 ft) 700 mm (27.6 in) 250 mm (9.8 in) 90 mm (3.5 in) 1.2 m (3.9 ft) 500 mm (19.7 in) 1.28 m (4.2 ft) 540 mm (21.3 in) 1.28 m (4.2 ft) 540 mm (21.3 in) 120 mm (4.7 in) 40 mm (1.6 in) 120 mm (4.7 in) 40 mm (1.6 in) E32-T11R 1m (3.3 ft) 140 mm (5.5 in) 4m (13.1 ft) 670 mm (26.4 in) Contact Omron Contact Omron 2.1 m (6.9 ft) 280 mm (11.0 in) 2.1 m (6.9 ft) 280 mm (11.0 in) Contact Omron Contact Omron 1.3 m (4.3 ft) 180 mm (7.1 in) 1.4 m (4.6 ft) 200 mm (7.9 in) 1.4 m (4.6 ft) 200 mm (7.9 in) Contact Omron Contact Omron Contact Omron Contact Omron E32-TC50 1.5 m (4.9 ft) 200 mm (7.9 in) Contact Omron Contact Omron -- -- 3m (9.8 ft) 400 mm (15.7 in) Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron 190 mm (7.5 in) 28 mm (1.1 in) E32-TC200 E32TC200C 1.5 m (4.9 ft) 200 mm (7.9 in) 4m (13.1 ft) 950 mm (37.4 in) 670 mm (26.4 in) 80 mm (3.1 in) 3m (9.8 ft) 400 mm (15.7 in) 3m (9.8 ft) 400 mm (15.7 in) 420 mm (16.5 in) 55 mm (2.2 in) 2m (6.6 ft) 270 mm (10.6 in) 2.1 m (6.9 ft) 290 mm (11.4 in) 2.1 m (6.9 ft) 290 mm (11.4 in) 190 mm (7.5 in) 28 mm (1.1 in) 190 mm (7.5 in) 28 mm (1.1 in) 800 mm (31.5 in) 150 mm (5.9 in) Contact Omron Contact Omron 350 mm (13.8 in) 60 mm (2.4 in) 1.6 m (5.2 ft) 300 mm (11.8 in) 3.6 m (11.8 ft) 300 mm (11.8 in) Contact Omron Contact Omron 800 mm (31.5 in) 200 mm (7.9 in) 850 mm (33.5 in) 210 mm (8.3 in) 850 mm (33.5 in) 210 mm (8.3 in) 100 mm (3.9 in) 18 mm (0.7 in) 100 mm (3.9 in) 18 mm (0.7 in) E32-TC500 E32TC1000 1.5 m (4.9 ft) 200 mm (7.9 in) Contact Omron Contact Omron -- -- 3m (9.8 ft) 400 mm (15.7 in) Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron -- -- 1m (3.3 ft) 500 mm (19.7 in) Contact Omron Contact Omron 1m (3.3 ft) 500 mm (19.7 in) 1m (3.3 ft) 500 mm (19.7 in) Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron Contact Omron 1m (3.3 ft) 500 mm (19.7 in) E32-T61 1.5 m (4.9 ft) 150 mm (5.9 in) 4m (13.1 ft) 570 mm (22.4 in) 450 mm (17.7 in) 60 mm (2.4 in) 3m (9.8 ft) 300 mm (11.8 in) 3m (9.8 ft) 300 mm (11.8 in) Contact Omron Contact Omron 2m (6.6 ft) 180 mm (7.1 in) 2.1 m (6.9 ft) 190 mm (7.5 in) 2.1 m (6.9 ft) 190 mm (7.5 in) 130 mm (5.1 in) 18 mm (0.7 in) 130 mm (5.1 in) 18 mm (0.7 in) 4 E39 E39-F2 Side View Attachment These attachments provide 90 angle viewing for through-beam cables. Use then with E32-TC50, E32-TC200 and E32TC200C plastic filament cables and E32T61 glass filament cables. Screw each piece onto the threaded tip of each sensing head. Note: This attachment does not increase sensing distance. E39 E39-F3 Diffuse Reflective Conversion Bracket This bracket converts through-beam fiber cables for diffuse reflective sensing. Use it with E32-TC50, E32-TC200 and E32TC200C plastic filament cables. A set of E39-F1 lenses are supplied with this conversion bracket. To install, first remove the mounting nuts from the fiber-optic sensing heads. Then loosen the two set screws on the bracket. Insert the sensing ends through the bracket, then attach the lenses. Tighten the two set screws to hold the sensing heads in place. Mount the bracket at the detection site, then loosen the large center screw to adjust the angle. When the angle that produces reliable detection has been found, tighten the screw to retain that angle. E39-F3A Reflective Unit Lens (for E32-D32 Fiber) When E39-F3A is attached to an E32-D32 fiber, adjust the focal point so that the amplifier will not detect its own light reflected from inside the E39-F3A. Place the object to be detected or while paper at the sensing distance, then adjust the insertion depth of the fiber into the E39-F3A so that the light spot is as small as possible. Then fasten the sensing head using the Allen head wrench supplied with the E39-F3A. In the example shown, A = The focus is farther than the E39-F3A B = The focus is closer than the E39-F3A. E39-F5 Diffuse Reflective Side View Conversion Block This reflective side view block may be used with E32-TC200A plastic filament fiber-optic cable only. It provides a 2 cm (0.79 in) sensing distance. To install, first remove mounting nuts and washers from fiber-optic sensing head. Then, screw the threaded heads as far as they will go onto the mounting holes on the narrow side of the block. 5 E39 Protective Stainless Steel Tubes Insert the fiber into the protective armor tube from the head connector side (threaded) of the tube. Secure the tube on a suitable place with the attached nut. E39 position other than at the end cap, apply tape to the tube so that the portion becomes thicker in diameter Push the fiber into the armor tube. The tube should be straight so that the fiber is not twisted when inserted. Then turn the end cap of the tube. Use the attached saddle to secure the end cap of the tube. To secure the tube at a Chemical Resistance Do NOT use a fiber-optic cable and amplifier in an atmosphere containing organic solvents such as paint thinner vapors. NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. One East Commerce Drive Schaumburg, IL 60173 OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON Cat. No. CEDSAX3 416-286-6465 10/99 Specifications subject to change without notice. Printed in the U.S.A. 6 |
Price & Availability of E3X-DA |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |