 POWER GENERAL
HD2-100 Series
100W DUAL OUTPUT DC-DC CONVERTER
-- Independent Dual Low-Voltage Outputs --
Features
* Independently Regulated Outputs 5V and 3.3V 5V and 2.5V 3.3V and 2.5V 3.3V and 1.8V 2.5V and 1.8V * 36-75 VDC Input (48V Nominal) * 84% Efficiency (Typ.) * Remote On/Off * Built-in EMI Suppression Filter * Fixed Operating Frequency * Under-Voltage Lockout * Over-Voltage Shutdown * Short-Circuit Protection * Thermal Protection * 1500V I/O Isolation * International Safety Standards * Compact 2.4"x2.3"x0.5" Package * Aluminum Base Plate * Two-Year Warranty * 600,000-Hour Minimum MTBF
HD2-100 Characteristics
Input Voltage............................................................ Input Current............................................................ EMI Suppression ..................................................... Input/Output Isolation .............................................. Continuous Output Power ....................................... DC Output................................................................ Base-Plate Temperature.......................................... Output Voltage Adjustment ...................................... Short-Circuit Protection ........................................... Under-Voltage Protection ........................................ Over-Voltage Protection .......................................... Transient Response................................................. Frequency of Operation........................................... 36-75 VDC (48V, nominal). 2.5A, typical at nominal input (Note 1). Pi input filter, standard. 1500 VDC, input to output, for one minute. Total output power should not exceed 100W. See Electrical Characteristics table. +100C, maximum: Internal thermal shutdown circuitry; automatic recovery. Outputs V1 and V2 each adjustable by 5%, minimum. Continuous cycle-by-cycle current limiting, each output, with automatic recovery Lockout activated at 34V- 35.5V input; automatic recovery with 2V3V hysteresis (typical). 5V output,shutdown at 6.5V, typical; 3.3V output, shutdown at 3.9V, typical; 2.5V output, shutdown at 3.2V, typical. RESET at VIN = 0V. 200s recovery after half-load to full load step change to within 1% of the regulation band with no more than 5% deviation. 400 kHz, fixed.
POWER GENERAL
A Division of Nidec America Corporation 152 Will Drive * Canton, MA 02021 USA * Phone 781-828-6216 * Fax 781-830-1155 * Email power@nidecpg.com * http://www.nidec.com
POWER GENERAL
HD2-100 Characteristics (Continued)
HD2-100 Series
Design Topology ...................................................... Forward converter with secondary side controller. Each output regulated by an independent control loop. Efficiency ................................................................. 84%, typical, at nominal input voltage, full load (Note 3). Remote Shutdown ................................................... OFF = Pin 3 at 1.4V or less. ON = Pin 3 >1.4V (to VIN(MAX)) or open. Operating Temperature Range................................ -40C to +100C (baseplate). Temperature Coefficient .......................................... 0.02%/C over the operating temperature range. Relative Humidity .................................................... 0% to 95%, non-condensing. Altitude .................................................................... 0 to 10,000 feet. Storage Temperature Range................................... -40C to +100C. Storage Humidity..................................................... 0% to 95%, non-condensing. Mean Time Between Failures .................................>600,000 hours, calculated using Bellcore TR-NWT-000332 (TA= +40C).
Electrical Characteristics
Output Voltage Output (V) V1 V2 V1 V2 V1 V2 V1 V2 V1 V2 5.0 3.3 5.0 2.5 3.3 2.5 2.5 1.8 3.3 1.8 Output Current Min. Max. (A) (A) 1.0 0.0 1.0 0.0 1.0 0.0 1.0 0.0 1.0 0.0 20 25 20 25 25 25 25 25 25 25 Output Voltage Tolerance 1.0% 1.5% 1.0% 1.5% 1.0% 1.5% 1.0% 1.5% 1.0% 1.5% Ripple & Noise 5 (mVpp) 100 100 100 100 100 100 100 100 100 100 Line Regulation 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% 0.2% Load Regulation 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
Model Number HD2-100-1D HD2-100-2D HD2-100-3D HD2-100-4D HD2-100-5D Notes
6
6,7
1. Use of an external input line fuse is recommended: Use a 5.0A/125V slow-blow fuse. 2. Peak-to-peak and RMS metering equipment must have a 20 MHz frequency response with probes and cables that maintain a frequency response of 20 Hz to 20 MHz. Output ripple and spikes are measured directly at the output terminals of the converter with a 0.1 F ceramic capacitor. The probe ground band must make direct contact with the output return or the common terminal of the converter to prevent erroneous noise measurements. 3. Output = 5V/20A. 4. All measurements are at nominal input, full load, and +25C, unless otherwise specified 5. Ripple and noise figures are maximum values. See application note below. 6. Preliminary data. 7. Remote shutdown operation for model HD2-100-5D is inverted: ON = Pin 3 at 1.4V or less. OFF = Pin 3 >1.4V (to VIN(MAX)) or open.
Ripple/Noise Reduction
In applications with loads between two and three inches from the HD2-100 module, the circuit board's trace inductance can be used in conjunction with a 47 F, low-ESR capacitor across each load to lower ripple and noise to 50 mVpp.
--2--
POWER GENERAL
HD2-100 Series
Mechanical Outline and Output Configuration
Pin-Out
Pin 1
2 3 4 5 6 7 8 9 10
Function
-VIN Case On/Off +VIN V2 Out V2 Rtn V2 Adj V1 Out V1 Rtn V1 Adj
Diameter*
0.040 0.040 0.040 0.040 0.080 0.080 0.040 0.080 0.080 0.040 in. in. in. in. in. in. in. in. in. in.
Output Adjustment
Dimension Notes 1. Dimensions above are in inches. 2. Tolerances: 0.000 = 0.007 inches. 0.00 = 0.010 inches.
* 0.002 inches
Specifications are subject to change without notice. PG/AAAG


▲Up To Search▲   

 
Price & Availability of HD2-100-2D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X