 HJF-A Series
0 /180 POWER DIVIDERS/COMBINERS
5 to 500 MHz / 4-Port Hybrid Junction / High Isolation / Low Insertion Loss / Hi-Rel Hermetic Pkg
Functional Schematic, shown used as 0/180 Power Divider
PRINCIPAL SPECIFICATIONS
Model Number HJF-A-200 Frequency Range, MHz 5 - 400 Performance Bandwidth, MHz 5 - 10 10 - 200 200 - 400 100 - 500 Isolation, E - H Ports, dB, Min 30 30 30 25 Insertion Loss, dB, Max. 1.5 1.0 1.5 1.5 Amplitude Phase Balance, Balance, dB, Max. Max. 0.4 0.3 0.4 0.4 3 3 3 4 VSWR, Max. 1.5:1 1.3:1 1.5:1 1.4:1
HJF-A-300
100 - 500
A-Size Flatpack Outline
GENERAL SPECIFICATIONS
Impedance: Coupling: CW Input: Weight: Operating Temperature: 50 nom. -- 3 dB nom. 1 Watt max. 0.1 oz (2.8 g)nom. -- 55 to +85C
Input/Output Relationships
E Isol. In H In Isol. 1 0 ref. 0 ref. 2 0 -- 180
NOTES:
1. Tolerance on 3 place decimals .010(.25) except as noted. 2. Dimensions in inches over millimeters. 3. All unmarked pins are case ground. 4. Dimensions marked with * apply only at body.
Typical HJF-A-200 Performance
General Notes:
1. The HJF-A series of four port hybrid junctions uses lumped element circuits to provide a variety of signal processing functions. Among these are: a) Power division with phase shift: Signals applied to the delta () port, or E-arm, will divide equally between output ports 1 and 2 (co-linear arms) and be 180 out of phase. b) Power division with no phase shift: Signals applied to the sum () port, or H-arm, will divide equally between output ports 1 and 2 (co-linear arms) and be in phase. c) Vector addition: Simultaneous application of signals to both E and H arms results in their vector addition to one co-linear port and vector subtraction at the other. Correction for the phase difference between E and H paths to the co-linear ports must be made . This phase equalization may be applied externally or factory installed within the unit at additional cost. 2. All units comply with MIL-P-23971 and can be supplied screened for compliance with additional specifications for military and aerospace applications requiring the highest reliability.
22Feb96
For further information contact MERRIMAC / 41 Fairfield Pl., West Caldwell, NJ, 07006 / 973-575-1300 / FAX 973-575-0531


▲Up To Search▲   

 
Price & Availability of HJF-A-300

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X