If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Series MX 2-Pole or 3-Pole 4A 460 Vac DIN-Rail SSR Part Number MX2P46D4T-02 MX3P46D4S-02 Description 4A, 460 Vac 4A, 460 Vac Part Number Explanation MX 2P 46 D 4 T -02 NOTES 1) Poles: 2P = 2 pole; 3P = 3 pole 2) Line Voltage: 46 = 460 Vac 3) Switch Type: D = Zero-cross turn-on 4) Control Range: T = 15-40 Vdc; S = 12-35 Vdc 5) Options: 02 = With LED FEATURES/BENEFITS * New generation of solid-state relays for DIN-rail mounting * Two- or three-pole output with single control * Tight zero-cross window for low EMI * Control visualization by LED * Integrated clamping voltage * High immunity to surges DESCRIPTION The Series MX relays are a new generation of solidstate relays for DIN-rail fixation. The MX relays are internally wired to provide a common control. The relays are placed on a single DIN-rail fixture, saving designers time and space. The Series MX relays provide a control status LED and internal output protection. APPLICATIONS * Interface applications * Vending machines * Light/lamp control * Contactor driver * Fan speed control * HVAC controls * Heating control MECHANICAL SPECIFICATION L1 L2 L3 input output 6-30Vdc 400Vac 4A L1 L2 A1+ 1 3.01 (76.4) 0.4 A1+ A1- L1 L2 4- 3+ T1 T2 Input 24-460Vac 12-35Vdc 4A AC3 A1T1 T2 A2- A1+ input 10-35VDC T1 T2 T3 1.14 2.09 0.2 0.2 (29) 0.1 (53) .98 (25) MX2P46D4T-02 1.87 0.1 (47.5) WEIGHT: 1.06 oz (30g) MX3P46D4S-02 Figure 1 -- MX relays; dimensions in inches (mm) INPUT (CONTROL) SPECIFICATION Min Control Range MX2P46D4T-02 MX3P46D4S-02 Input Current Range MX2P46D4T-02 MX3P46D4S-02 Must Turn-Off Voltage MX2P46D4T-02 MX3P46D4S-02 Input Resistance (Typical) MX2P46D4T-02 MX3P46D4S-02 (c) 2003 TELEDYNE RELAYS Max 40 35 Units V V 15 12 4.4 7.5 17 30 mA mA A1 + Rc 3.01 (76.4) 2 0.4 BLOCK DIAGRAM A1 + Rc L1 L1 T1 8 6 V V T1 L2 T2 L2 L3 A1 - T2 2000 1000 Ohms Ohms A1 - T3 Figure 2a -- MX2P relay Figure 2b -- MX3P relay MX 1 MX\032003\Q1 (800) 284-7007 * www.teledynerelays.com Series MX CONTROL CHARACTERISTICS 18 16 OUTPUT (LOAD) SPECIFICATION Min Operating Range Peak Voltage Load Current Range (Resistive) Inductive Load Current (See Figure 5) On-State Voltage Drop Zero-Cross Window Off-State Leakage Current (60Hz) Turn-On Time (60Hz) Turn-Off Time (60Hz) .005 4 2.5 120 1.6 12 0.3 8.3 8.3 500 10 440 50 Arms Arms A V V mA ms ms V/s Hz A2S 24 Max 460 1200 Unit Vrms V Input Current (mA) 14 12 10 8 6 4 2 0 0 5 10 15 20 25 30 35 40 Maximum Surge Current Rating (Non-Repetitive) Control Voltage (V) Figure 3a -- MX2P relay 30 25 Input Current (mA) 20 Off-State dv/dt Operating Frequency I t for match fusing (<8.3ms) 2 15 10 5 0 0 5 10 15 20 25 30 35 ENVIRONMENTAL SPECIFICATION Control Voltage (V) Min Operating Temperature Storage Temperature Input-Output Isolation Input-Output Capacity -40 -40 Max 80 150 4000 3 Unit C C Vrms pF Figure 3b -- MX3P relay TYPICAL APPLICATIONS 3 phases 200 up to 480 Vac L1 L2 L3 Y wiring SURGE CURRENT 150 Non-Repetitive wiring Apeak 100 50 Repetitive with initial Tj = 70C 0 single phase 0.01 0.1 t(s) 1 10 Figure 5 -- MX relays Figure 4a -- MX2P relay L1 L2 L3 LOAD Figure 4b -- MX3P relay MX 2 NOTES: 1. Electrical parameters at 25C unless otherwise specified. 2. For 800Hz applications, contact factory. 3. For additional/custom options, contact factory. (c) 2003 TELEDYNE RELAYS MX\032003\Q1 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE |
Price & Availability of MX2P46D4T-02
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |