![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
1500W True Sine Wave DC-AC Inverter with Solar Charger Features : TN-1500 series True sine wave output (THD<3%) SPECIFICATION MODEL RATED POWER (Typ.) MAXIMUM OUTPUT POWER AC VOLTAGE FREQUENCY OUTPUT WAVEFORM AC REGULATION (Typ.) TRANSFER TIME SAVING MODE (Typ.) FRONT PANEL INDICATOR BAT. VOLTAGE DC CURRENT (Typ.) INPUT NO LOAD DISSIPATION OFF MODE CURRENT DRAW EFFICIENCY (Typ.) BATTERY TYPES FUSE BATTERY BAT. LOW ALARM INPUT PROTECTION BAT. LOW SHUTDOWN REVERSE POLARITY TN-1500-112 1500W TN-1500-124 High surge power up to 3000W U.P.S. mode and energy saving mode (selectable) High efficiency up to 91% Power ON-OFF switch Standby saving mode can be selectable Front panel indicator for operation status Thermostatically controlled cooling fan Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp. / Output short / Input polarity reverse / Overload / AC circuit breaker Application : Home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. Built-in solar / AC charger Optional monitoring software 2 years warranty E13 TN-1500-148 TN-1500-212 TN-1500-224 TN-1500-248 1725W for 180 sec. / 2250W for 10 sec. / surge power 3000W for 30 cycles Factory setting set at 110VAC 100 / 110 / 115 / 120VAC selectable by setting button S.W Factory setting set at 230VAC 200 / 220 / 230 / 240VAC selectable by setting button S.W 60 0.1Hz 3.0% 50/60Hz selectable by setting button S.W 50 0.1%Hz 50/60Hz selectable by setting button S.W True sine wave (THD<3%) at rated input voltage t<10ms inverter Load 12V Note.5 150A by pass 5W will be changed to standby mode 24V Battery voltage level, output load level, saving mode, fault and operation status 48V 42 ~ 60VDC 37.5A 12V 10.5 ~ 15VDC 150A 24V 21 ~ 30VDC 75A 48V 42 ~ 60VDC 37.5A 21 ~ 30VDC 75A VOLTAGE RANGE (Typ.)Note.1 10.5 ~ 15VDC 18W @ standby saving mode 1mA 89% Open & sealed Lead Acid 30A*3 22.5 4% 21 4% 82 5 90% 30A*2 45 4% 42 4% 96 5 88% 40A*5 11.3 4% 10.5 4% 68 5 90% 30A*3 22.5 4% 21 4% 68 5 91% 30A*2 45 4% 42 4% 68 5 Note.2 87% 40A*5 11.3 4% 10.5 4% By internal fuse open 82 5 OVER TEMPERATURE OUTPUT SHORT OUTPUT PROTECTION OVER LOAD (Typ.) CIRCUIT BREAKER GFCI PROCTECTION WORKING TEMP. ENVIRONMENT WORKING HUMIDITY Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH3 detect on heatsink of power transistor Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover 20A Optional (Only type F) Note.3 0 ~ +40 @ 100% load ; 60 @ 50% load 20% ~ 90% RH non-condensing -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH o 10A None STORAGE TEMP., HUMIDITY VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes EN60950-1 UL458 (only for "GFCI" receptacles-Type F ) Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE, E-Mark EMI CONDUCTION&RADIATION Compliance to FCC class A ----Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204 EMS IMMUNITY AC CHARGER SOLAR CHARGER CHARGE CURRENT (Typ.) CHARGE VOLTAGE CHARGE CURRENT (max.) CHARGE VOLTAGE CONTROL WIRING DIMENSION PACKING 5.5A 14.3V 4% 30A 2.7A 28.5V 4% 45V 1.35A 57V 4% 75V 57V 4% 5.5A 14.3V 4% 25V 14.3V 4% 2.7A 28.5V 4% 45V 28.5V 4% 1.35A 57V 4% 75V 57V 4% MAX OPEN CIRCUIT VOLTAGE 25V 28.5V 4% 14.3V 4% RJ11 -RS232 (Option) 420*220*88mm (L*W*H) 6.85Kg; 2pcs/14.7Kg/1.61CUFT OTHERS NOTE 1.Output derating capacity referenced by curve 1. 2.Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage. 3.Output derating capacity referenced by curve 2. 4.All parameters not specified above are measured at rated load, 25 of ambient temperature. 5.DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage. File Name:TN-1500-SPEC 2008-07-29 1500W True Sine Wave DC-AC Inverter with Solar Charger TN-1500 series Instructions for TN-1500 monitoring software 1. Installation of TN-1500 unit and PC 1 6 Phone Jack RJ11 DB9 FEMALE RJ11 PIN NO. DB9 PIN NO. 2 3 3 5 4 2 9 8 7 6 5 4 3 2 1 Figure 1 2. Explanation of Monitoring Manu 2.1 Main Page Inverter TN V.1.1 Setting Statistics R.C. Power off Pause Exit 1 2 3 4 Solar Charge AC Charge 100 0 Battery Battery Voltage 54.1 V INVERTER 100 0 Loading O/P Voltage 110 V O/P Frequency 60.0 Hz 5 Internal Temperature 10.0 AC In Utility Voltage 0.0 V TN-1500-143 By pass Start Date 2007/12/07 03:13:33 PM Reset Date 2007/12/21 01:40:56 PM 6 Power on Remote off Battery low Battery used up Stand by saving mode Abnormal Shutdown Figure 2 1. Setting: Adjustment for output voltage, charging related voltage, frequency, and operation mode. Please refer to Figure 3 for details. 2. Statistics: Calculate for the percentage of operating period for each operation mode. Please refer to Figure 4 for details. 3. R.C. Power off: Power can be turned ON or OFF at the remote location. 4. Pause: Stop refreshing the page of monitoring software. 5. Status of unit: Indicating current operating status of TN-1500. 6. Signals that display current condition of the unit. File Name:TN-1500-SPEC 2008-07-29 1500W True Sine Wave DC-AC Inverter with Solar Charger TN-1500 series 2.2 Setting Page Inverter Setting File Name D:\TN_110RR\20071205\REV\TN_110RR\TNF\TN_1K5_512.TNF Model name TN-1500-212 Manufacture MeanWell Revision REV:1.10 I/O Type Voltage Frequency Stand-by saving mode UPS mode Energy saving mode 212 230 50 On On On 1 Lead Hz Off V Series Number Date Of Manu. Equalization Volt. Floating Volt. Alarm Volt. Shutdown Volt. LOC-1234567890 06/23/2007 14.3 13.3 11.3 10.5 V V V V 13.5 ~ 15.0V 13.0 ~ 13.5V 1 11.0 ~ 11.5V 10.0 ~ 11.0V Comm Ports Read Write Bauds Rate 9600 Exit Read OK!! 2 3 4 Figure 3 1. User can adjust the settings based on the characteristics of batteries been used: Equalization Voltage, Floating Voltage, Alarm Voltage, and Shut-down Voltage. UPS Mode / Energy Saving Mode selection and AC output voltage and frequency can also be set in this page. 2. Read: Read current settings of the unit. 3. Write: Write the revised setting into the unit. 4. Load: Load in factory default settings. 2.3 Statistic Page Inverter Setting Start Date 2007/12/07 03:13:33 PM Inverter time rate 91.2 % Bypass time rate 0.0 % Shut Down rate 8.8 % Solar time rate 0.0 % Loading average 24.7 % Start Date 2007/12/21 01:40:56 PM Inverter time rate 31.9 % Bypass time rate 0.0 % Shut Down rate 68.1 % Solar time rate 0.0 % Loading average 63.7 % RESET Exit Figure 4 1. Start Date: Date that installing the monitoring software. 2. Reset Date: Date that resetting the statistics. The Start Date will not be influenced by resetting the statistics or turning off the unit. 3 .Inverter time rate: Operating period of "Inverter Mode" represents how many percent of the whole operating period. 4. Bypass time rate: Operating period of "Bypass Mode" (energy provides directly by the utility) represents how many percent of the whole operating period. 5. Shut down rate: Percentage of time period that the unit is under the condition of shut down. * Inverter time rate + Bypass time rate + Shut down rate = 100% 6. Solar time rate: Percentage of time period that the solar charger is functioning after turning on the TN-1500 unit. 7. Loading average: Average loading after turning on the TN-1500 unit. File Name:TN-1500-SPEC 2008-07-29 1500W True Sine Wave DC-AC Inverter with Solar Charger TN-1500 series TN True sine wave inverter +AC charger and solar charger 1500 112 A 12:12VDC Bat. Voltage: 24:24VDC 48:48VDC Output: 1:110VAC 2:230VAC O/P Wattage:1500W A :TYPE A OUTLET B :TYPE B OUTLET C :TYPE C OUTLET D :TYPE D OUTLET E :TYPE E OUTLET F :TYPE F OUTLET AC Output Receptacles (optional) TYPE-A USA TYPE-B EUROPE TYPE-C AUSTRALIA TYPE-D U.K TYPE-E JAPAN TYPE-F GFCI Mechanical Specification Unit:mm 12.1 Air flow direction 57.75 36.25 15.6 27.45 11.05 108.4 44.25 SOLAR CHARGE AC CHARGE BATTERY 100 20 10 47 7 203.2 420 AC OUTPUT ON OFF LOAD 100 Setting On 0 INVERTER 0 r cu it Br e ak er AC IN BY PASS Bat Low Saving Ci s to R se t e Remote port Type-A AC OUTPUT SOLAR CHARGE ON AC CHARGE BATTERY 100 OFF LOAD 100 Setting On 0 INVERTER 0 r cu it Br e ak er AC IN BY PASS Bat Low Saving Ci s to R se t e Remote port 207 220 Type-B File Name:TN-1500-SPEC 2008-07-29 88 AC INPUT NEG POS DC INPUT Solar Input (30A max) Reverse Polarity Will Damage The Unit. Cat.No.(1GG1HS-212) Wire Range(10-4 AWG Str Cu Soldered Wires) Torque (17.7-26.5 in lb) Chassis Ground 48 22 es Pr es Pr |
Price & Availability of TN-1500
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |