![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Embedded Power for Business-Critical Continuity LPS40 Series 40 Watts Total Power: Input Voltage: # of Outputs: 40-55Watts 85-264VAC 120-300VDC Single Rev. 7.8.09_4 LPS40 Series of 3 Special Features * * * * * * * * * * * * Universalinput 3"x5"footprint Lessthan1Uhigh Remotesense Terminalblockoption(-T) Built-inEMIfilter Lowoutputripple Adjustableoutput Overvoltageprotection Overloadprotection 110KHzswitchingfrequency LPX40enclosurekitavailable Electrical Specifications Input Inputrange: Frequency: Inrushcurrent: Inputcurrent: Efficiency: EMIfilter: Safetyground leakagecurrent: 85-264VAC;120-300VDC 47-440Hz <18Apeak@115VAC;<36Apeak@230VAC,coldstart@25C 1Amax.(RMS)@115VAC 70% typical at full load FCCClassBconducted;CISPR22ClassBconducted; EN55022ClassBconducted;VDE0878PT3classBconducted <0.5mA@50/60Hz,264VACinput Output Maximumpower: Adjustmentrange: Hold-uptime: Overloadprotection: 40Wforconvection;55Wwith30CFMforcedair -5,+10%minimum 20ms@40Wload,115VACnominalline Shortcircuitprotectiononalloutputs Caseoverloadprotected@110 -145%abovepeakrating Safety * UL UL60950 E132002 * CSA CSA22.2-234Level3 LR53982C * NEMKOEN60950/EMKO-TUE P94100375(74-sec)203 * CB Certificate and report 1119,1125,1126,1127 * CE Mark(LVD) Overvoltageprotection: 5Voutput;5.7to6.7VDC.Otheroutputs10%to25%abovenominal output Remotesense: Compensatesfor0.5Vleaddropminimum Willoperatewithoutremotesenseconnected Reverseconnectionprotected Embedded Power for Business-Critical Continuity EnvironmentalSpecifications Operatingtemperature: 0to50Cambient.Derateeachoutput2.5%perdegreefrom50to70C,-20Cstartup. Storagetemperature: -40Cto+85C Temperaturecoefficient: 0.4%perC Electromagnetic DesignedtomeetIEC801,-2,-3,-4,-5,-6,Level3 susceptibility: Humidity: Vibration: MTBFdemonstrated: Operating;non-condensing5%to95%RH Threeorthogonalaxes,sweepat1oct/min,5min.dwellatfourmajorresonances0.75Gpeak5Hz to500Hz,operational >550,000hoursatfullloadand25Cambientconditions Rev. 7.8.09_4 LPS40 Series of 3 OrderingInformation ModelNumber LPS41(-T) LPS42(-T) LPS43(-T) LPS44(-T) LPS45(-T) LPS48(-T) Output Minimum MaximumLoadwith Voltage Load ConvectionCooling 3.3V 5V 12V 15V 24V 48V 0A 0A 0A 0A 0A 0A 8A 8A 3.3A 2.6A 1.7A 0.9A MaximumLoadwith 30CFMForcedAir 11A 11A 4.5A 3.6A 2.3A 1.2A PeakLoad1 Regulation2 RippleP/P(PARD)3 12A 12A 5A 4A 2.5A 1.3A 2% 2% 2% 2% 2% 2% 50mV 50mV 120mV 150mV 240mV 480mV 1. Peakcurrentlasting<30secondswithamaximum10%dutycycle. 2. At25Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactorysettings. 3. Peak-to-peakwith20MHzbandwidthand10Finparallelwitha0.1Fcapacitoratratedlinevoltageandloadranges. 4. (-T)indicatesTerminalBlockoptionforinputandoutput(insteadofMolextype) Power Derating Curve 55W 30 CFM Forced Air Cooling 40W 30W Output Power (Watts) 20W Natural Convection Cooling 27.5W 20W 10W 0W 0C 10C 20C 30C 40C 50C 60C 70C TA - Ambient Temperature - C Embedded Power for Business-Critical Continuity MechanicalDrawing 0.22" (5.6) M1 GND 4.55" (115.6) 5.00" (127) Americas 5810VanAllenWay Carlsbad,CA92008 USA Telephone:+17609304600 Facsimile: +17609300698 Rev. 7.8.09_4 LPS40 Series 3 of 3 SK201 M2 _ + SK 2 3.00" (76.2) 2.55" (64.8) 3 1 Remote Sense Connector Voltage Adj. Pot Europe (UK) SK 1 N L 1 2 3 4 5 6 WaterfrontBusinessPark MerryHill,Dudley WestMidlands,DY51LX UnitedKingdom Telephone:+44(0)1384842211 Facsimile: +44(0)1384843355 Asia (HK) 0.15" (4) DIA (4 places) 14/F,LuPlaza 2WingYipStreet KwunTong,Kowloon HongKong Telephone:+85221763333 Facsimile: +85221763888 Forglobalcontact,visit: www.PowerConversion.com 1.14" (29) techsupport.embeddedpower @emerson.com 0.197" (5) Whileeveryprecautionhasbeentakentoensure accuracyandcompletenessinthisliterature,Emerson NetworkPowerassumesnoresponsibility,anddisclaims allliabilityfordamagesresultingfromuseofthis informationorforanyerrorsoromissions. PinAssignments Connector SK1-1 SK1-3 SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 ACInput: LPS41 Line Neutral +3.3V +3.3V +3.3V Common Common Common +Sense -Sense LPS42 Line Neutral +5V +5V +5V Common Common Common +Sense -Sense LPS43 Line Neutral +12V +12V +12V Common Common Common +Sense -Sense LPS44 Line Neutral +15V +15V +15V Common Common Common +Sense -Sense LPS45 Line Neutral +24V +24V +24V Common Common Common +Sense -Sense LPS48 Line Neutral +48V +48V +48V Common Common Common +Sense -Sense Emerson Network Power. Thegloballeaderinenabling business-criticalcontinuity. ACPower Connectivity DCPower EmbeddedComputing Embedded Power Monitoring OutsidePlant PowerSwitching&Controls PrecisionCooling Racks&IntegratedCabinets Services SurgeProtection EmersonNetworkPower.com EmersonNetworkPowerandtheEmerson NetworkPowerlogoaretrademarksand servicemarksofEmersonElectricCo. (c)2009EmersonElectricCo. MatingConnectors Molex09-50-8031(USA)Notrequiredfor(-T)option 09-91-0300(UK) PINS:08-52-0113 DCOutputs: Molex09-50-8061(USA)Notrequiredfor(-T)option 09-91-0600(UK) PINS:08-52-0113 Remote Molex22-01-2025 Sense: PINS:08-52-0123 EmersonNetworkPowerConnectorKit#70-841-006,includesalloftheabove 1. Specificationssubjecttochangewithoutnotice. 2. Alldimensionsininches(mm),toleranceis0.02"(0.5mm) 3. MountingholesM1andM2shouldbegroundedforEMIpurposes. 4. MountingholeM1issafetygroundconnection. 5. Specificationsareforconvectionratingatfactorysettingsat115VACinput,25Cunlessotherwisestated. 6. Warranty:2year 7. Weight:0.5lbs/0.23kg |
Price & Availability of LPS4109
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |