  Datasheet File OCR Text:
 FERROXCUBE
DATA SH EET A SHEET
E58/11/38 Planar E cores and accessories
Supersedes data of February 2002 2004 Sep 01
Ferroxcube
Planar E cores and accessories
CORES Effective core parameters of a set of E cores SYMBOL (I/A) Ve Ie Ae Amin m PARAMETER core factor (C1) effective volume effective length effective area minimum area mass of core half VALUE 0.268 24600 80.6 308 308 62 UNIT mm-1 mm3 mm mm2 mm2 g
handbook, halfpage
E58/11/38
58.4 1.2 50 min. 8.1 0.2 6.5 0.13 10.5 0.13
38.1 0.8
R0.64 ref. typ.
R0.81 ref. typ.
CBW413
Dimensions in mm.
Fig.1 E58/11/38 core half.
Effective core parameters of an E/PLT combination SYMBOL (I/A) Ve Ie Ae Amin m PARAMETER core factor (C1) effective volume effective length effective area minimum area mass of core half VALUE 0.224 20800 67.7 310 310 44 UNIT mm-1 mm3 mm mm2 mm2 g
handbook, halfpage
58.4 1.2 4.1 0.13
Ordering information for plates GRADE 3C90 3C92 3C93 3C94 3F3 3F4 TYPE NUMBER PLT58/38/4-3C90 PLT58/38/4-3C92 PLT58/38/4-3C93 PLT58/38/4-3C94 PLT58/38/4-3F3 PLT58/38/4-3F4
Dimensions in mm.
CBW414
38.1 0.8
R0.64 ref. typ.
Fig.2 PLT 58/38/4.
2004 Sep 01
2
Ferroxcube
Planar E cores and accessories
E58/11/38
Core halves for use in combination with an E core AL measured in combination with a non-gapped core half, clamping force for AL measurements, 40 20 N, unless stated otherwise. GRADE 3C90 AL (nH) 315 3%(1) 400 630 3%(1) 5%(1) e 67 85 134 213 341 1800 1410 1640 67 85 134 213 341 1800 67 85 134 213 341 1640 67 85 134 213 341 860 AIR GAP (m) 1400 1100 650 400 200 0 0 0 1400 1100 650 400 200 0 1400 1100 650 400 200 0 1400 1100 650 400 200 0 TYPE NUMBER E58/11/38-3C90-E315-E E58/11/38-3C90-E400-E E58/11/38-3C90-E630-E E58/11/38-3C90-A1000-E E58/11/38-3C90-A1600-E E58/11/38-3C90 E58/11/38-3C92 E58/11/38-3C93 E58/11/38-3C94-E315-E E58/11/38-3C94-E400-E E58/11/38-3C94-E630-E E58/11/38-3C94-A1000-E E58/11/38-3C94-A1600-E E58/11/38-3C94 E58/11/38-3F3-E315-E E58/11/38-3F3-E400-E E58/11/38-3F3-E630-E E58/11/38-3F3-A1000-E E58/11/38-3F3-A1600-E E58/11/38-3F3 E58/11/38-3F4-E315-E E58/11/38-3F4-E400-E E58/11/38-3F4-E630-E E58/11/38-3F4-A1000-E E58/11/38-3F4-A1600-E E58/11/38-3F4
1000 5% 1600 10% 8480 25% 3C92 3C93 3C94 6600 25% 7710 25% 315 630 3%(1) 5%(1) 400 3%(1) 1000 5% 1600 10% 8480 25% 3F3 315 400 3%(1) 3%(1)
630 5%(1) 1000 5% 1600 10% 7710 25% 3F4 315 400 3%(1) 3%(1)
630 5%(1) 1000 5% 1600 10% 4030 25% Note
1. Measured in combination with an equal gapped E core half, clamping force for AL measurements, 40 20 N.
2004 Sep 01
3
Ferroxcube
Planar E cores and accessories
Core halves for use in combination with a plate (PLT) AL measured in combination with a plate (PLT), clamping force for AL measurements, 40 20 N. GRADE 3C90 AL (nH) 315 3% 400 3% 630 5% 1000 5% 1600 10% 9970 25% 3C92 3C93 3C94 7770 25% 9070 25% 315 3% 400 3% 630 5% 1000 5% 1600 10% 9970 25% 3F3 315 3% 400 3% 630 5% 1000 5% 1600 10% 9070 25% 3F4 315 3% 400 3% 630 5% 1000 5% 1600 10% 4780 25% e 56 71 112 178 285 780 1390 1620 56 71 112 178 285 780 56 71 112 178 285 1620 56 71 112 178 285 850 AIR GAP (m) 1400 1100 650 400 200 0 0 0 1400 1100 650 400 200 0 1400 1100 650 400 200 0 1400 1100 650 400 200 0
E58/11/38
TYPE NUMBER E58/11/38-3C90-A315-P E58/11/38-3C90-A400-P E58/11/38-3C90-A630-P E58/11/38-3C90-A1000-P E58/11/38-3C90-A1600-P E58/11/38-3C90 E58/11/38-3C92 E58/11/38-3C93 E58/11/38-3C94-A315-P E58/11/38-3C94-A400-P E58/11/38-3C94-A630-P E58/11/38-3C94-A1000-P E58/11/38-3C94-A1600-P E58/11/38-3C94 E58/11/38-3F3-A315-P E58/11/38-3F3-A400-P E58/11/38-3F3-A630-P E58/11/38-3F3-A1000-P E58/11/38-3F3-A1600-P E58/11/38-3F3 E58/11/38-3F4-A315-P E58/11/38-3F4-A400-P E58/11/38-3F4-A630-P E58/11/38-3F4-A1000-P E58/11/38-3F4-A1600-P E58/11/38-3F4
2004 Sep 01
4
Ferroxcube
Planar E cores and accessories
Properties of core sets under power conditions B (mT) at GRADE H = 250 A/m; f = 10 kHz; T = 100 C 320 320 370 370 320 320 320 320 300 300 250 250 f = 100 kHz; B = 100 mT; T = 100 C 3.0 2.6 2.4 2.0 2.4(1) 2.0(1) 2.4 2.0 3.0 2.6 - - CORE LOSS (W) at f = 100 kHz; B = 200 mT; T = 100 C - - 15 13 15(1) 13(1) 15 13 - - - -
E58/11/38
f = 400 kHz; B = 50 mT; T = 100 C - - - - - - - - 4.7 4.0 - -
E+E58-3C90 E+PLT58-3C90 E+E58-3C92 E+PLT58-3C92 E+E58-3C93 E+PLT58-3C93 E+E58-3C94 E+PLT58-3C94 E+E58-3F3 E+PLT58-3F3 E+E58-3F4 E+PLT58-3F4
Measured at 140 C.
1.
Properties of core sets under power conditions (continued) B (mT) at GRADE H = 250 A/m; f = 10 kHz; T = 100 C 320 320 370 370 320 320 320 320 300 300 250 250 f = 500 kHz; B = 50 mT; T = 100 C - - - - - - - - - - - - CORE LOSS (W) at f = 500 kHz; B = 100 mT; T = 100 C - - - - - - - - - - - - f = 1 MHz; B = 30 mT; T = 100 C - - - - - - - - - - 7.4 6.25 f = 3 MHz; B = 10 mT; T = 100 C - - - - - - - - - - 12 10
E+E58-3C90 E+PLT58-3C90 E+E58-3C92 E+PLT58-3C92 E+E58-3C93 E+PLT58-3C93 E+E58-3C94 E+PLT58-3C94 E+E58-3F3 E+PLT58-3F3 E+E58-3F4 E+PLT58-3F4
2004 Sep 01
5
Ferroxcube
Planar E cores and accessories
DATA SHEET STATUS DEFINITIONS DATA SHEET STATUS Preliminary specification Product specification PRODUCT STATUS Development DEFINITIONS
E58/11/38
This data sheet contains preliminary data. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. This data sheet contains final specifications. Ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product.
Production
DISCLAIMER Life support applications These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Ferroxcube for any damages resulting from such application. PRODUCT STATUS DEFINITIONS STATUS Prototype Design-in Preferred Support INDICATION DEFINITION These are products that have been made as development samples for the purposes of technical evaluation only. The data for these types is provisional and is subject to change. These products are recommended for new designs. These products are recommended for use in current designs and are available via our sales channels. These products are not recommended for new designs and may not be available through all of our sales channels. Customers are advised to check for availability.
2004 Sep 01
6


▲Up To Search▲   

 
Price & Availability of E581138-3C94-E315-E

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X