  Datasheet File OCR Text:
 85W Quad Output Switching Power Supply
Features :
Universal AC input / Full range
RQ-85
series
Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105
long life electrolytic capacitors
Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty
SPECIFICATION
MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT RQ-85B CH1 5V 7A
Note.6 2 ~ 10A Note.6 80.7W
RQ-85C CH2 12V 3.1A 0.3 ~ 4A CH3 -5V 0.5A 0 ~ 1A CH4 -12V 0.5A 0 ~ 1A CH1 5V 7A 2 ~ 10A 82.5W CH1: 4.75 ~ 5.5V 2.0% +3,-7% 0.5% 1.0% 1.0% 3.0% CH2 15V 2.5A 0.3 ~ 4A CH3 -5V 0.5A 0 ~ 1A CH4 -15V 0.5A 0 ~ 1A
RQ-85D CH1 5V 6A 2 ~ 10A 84W CH1: 4.75 ~ 5.5V 2.0% +7,-3% 0.5% 1.0% 1.0% 3.0% CH2 12V 2A 0.3 ~ 4A CH3 24V 1A CH4 -12V 0.5A
0.1 ~ 1.5A 0 ~ 1A
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 100mVp-p 80mVp-p 80mVp-p 120mVp-p 100mVp-p 80mVp-p 80mVp-p 120mVp-p 150mVp-p 80mVp-p VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% +7,-3% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD
Note.4 Note.5
8.0% 1.0% 6.0%
5.0% 1.0% 2.0%
8.0% 1.0% 6.0%
5.0% 1.0% 2.0%
8.0% 1.0% 5.0%
5.0% 1.0% 2.0%
0.5% 1.0%
1.0% 3.0%
500ms, 20ms/230VAC 100ms/230VAC 88 ~ 264VAC 47 ~ 63Hz 76%
1200ms, 30ms/115VAC at full load
18ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 77% 78%
INPUT
2.5A/115VAC 1.5A/230VAC COLD START 40A/230VAC <2mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
(Note 7)
HARMONIC CURRENT EMS IMMUNITY MTBF
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A 206.8Khrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) 0.6Kg; 24pcs/15.4Kg/0.7CUFT )
OTHERS
DIMENSION PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
File Name:RQ-85-SPEC 2006-05-19
85W Quad Output Switching Power Supply
Mechanical Specification
RQ-85
Case No. 901
series
Unit:mm
4.5
152.5
1
8.25
2
4
65
3
3.5 84.5
2 -M 3
78 159 150
6 7 8
7
3 .5
4.5 24
6.5
9
18.5
9
22
117
Terminal Pin. No Assignment
Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5 6 Assignment DC OUTPUT -V4 DC OUTPUT V3 DC OUTPUT +V2 Pin No. 7 8 Assignment DC OUTPUT COM DC OUTPUT +V1
Derating Curve
Static Characteristics
Ta=25
100
100 90
80
80 70
60
LOAD (%)
LOAD (%)
40
60 50 40
20
-25 -25
0 0
10
20
30
40
50
60
70 (VERTICAL)
88
95
100
115
120
140
160
28.5
180
M3
18
38
200 220
3-
3.5
97
5
7
3 .5
240
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:RQ-85-SPEC 2006-05-19


▲Up To Search▲   

 
Price & Availability of RQ-85

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X