85W Quad Output Switching Power Supply Features : Universal AC input / Full range RQ-85 series Protections:Short circuit/Over load/Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105 long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70 Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty SPECIFICATION MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT RQ-85B CH1 5V 7A Note.6 2 ~ 10A Note.6 80.7W RQ-85C CH2 12V 3.1A 0.3 ~ 4A CH3 -5V 0.5A 0 ~ 1A CH4 -12V 0.5A 0 ~ 1A CH1 5V 7A 2 ~ 10A 82.5W CH1: 4.75 ~ 5.5V 2.0% +3,-7% 0.5% 1.0% 1.0% 3.0% CH2 15V 2.5A 0.3 ~ 4A CH3 -5V 0.5A 0 ~ 1A CH4 -15V 0.5A 0 ~ 1A RQ-85D CH1 5V 6A 2 ~ 10A 84W CH1: 4.75 ~ 5.5V 2.0% +7,-3% 0.5% 1.0% 1.0% 3.0% CH2 12V 2A 0.3 ~ 4A CH3 24V 1A CH4 -12V 0.5A 0.1 ~ 1.5A 0 ~ 1A RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 100mVp-p 80mVp-p 80mVp-p 120mVp-p 100mVp-p 80mVp-p 80mVp-p 120mVp-p 150mVp-p 80mVp-p VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% +7,-3% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD Note.4 Note.5 8.0% 1.0% 6.0% 5.0% 1.0% 2.0% 8.0% 1.0% 6.0% 5.0% 1.0% 2.0% 8.0% 1.0% 5.0% 5.0% 1.0% 2.0% 0.5% 1.0% 1.0% 3.0% 500ms, 20ms/230VAC 100ms/230VAC 88 ~ 264VAC 47 ~ 63Hz 76% 1200ms, 30ms/115VAC at full load 18ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 77% 78% INPUT 2.5A/115VAC 1.5A/230VAC COLD START 40A/230VAC <2mA / 240VAC 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 )on +5V output 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B (Note 7) HARMONIC CURRENT EMS IMMUNITY MTBF Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A 206.8Khrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) 0.6Kg; 24pcs/15.4Kg/0.7CUFT ) OTHERS DIMENSION PACKING NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can't exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. File Name:RQ-85-SPEC 2006-05-19 85W Quad Output Switching Power Supply Mechanical Specification RQ-85 Case No. 901 series Unit:mm 4.5 152.5 1 8.25 2 4 65 3 3.5 84.5 2 -M 3 78 159 150 6 7 8 7 3 .5 4.5 24 6.5 9 18.5 9 22 117 Terminal Pin. No Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG Pin No. 4 5 6 Assignment DC OUTPUT -V4 DC OUTPUT V3 DC OUTPUT +V2 Pin No. 7 8 Assignment DC OUTPUT COM DC OUTPUT +V1 Derating Curve Static Characteristics Ta=25 100 100 90 80 80 70 60 LOAD (%) LOAD (%) 40 60 50 40 20 -25 -25 0 0 10 20 30 40 50 60 70 (VERTICAL) 88 95 100 115 120 140 160 28.5 180 M3 18 38 200 220 3- 3.5 97 5 7 3 .5 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (VAC) 60Hz File Name:RQ-85-SPEC 2006-05-19 |
Price & Availability of RQ-85 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |