Part Number Hot Search : 
62747AFN TA8227A MAX9375 634RFKE 12TL4 7642ACTV 12TL4 SG684
Product Description
Full Text Search
 

To Download XCD Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 AC/DC Plug & Play Power Supply Series
400W-1200W
cite
AC/DC Power Supply
Ultra-high efficiency 1U size
The Xcite family of power supplies provides up to an incredible 1200W in an extremely compact 1U x 260 x 127mm package. Boasting industry leading power density of 15W/in3 and efficiencies of up to 90%, the Xcite family employs an innovative plug & play architecture that allows users to instantly configure a custom power solution in less than 5 minutes! Ultra high efficiencies and high power density are made possible through the combination of low loss technologies and the best field-proven technologies in planar magnetics and surface mount electronics. Significantly increased efficiency reduces system thermal load by more than 50%. The Xcite family consists of 4 powerPac models ranging in power levels from 400W to 1200W. Each model may be populated with up to 6 powerMods selected from the table of powerMods shown below. All configurations carry full safety agency approvals, UL60950, EN60950 and are CE marked. For alternative power interfaces contact support@excelsys.com patents pending
Standard
PLUG & PLAY POWER
next generation power source FEATURES
* * * * * 1.5V to 58V standard output voltages All outputs fully floating Extra low profile: 1U height (40mm) Ultra high efficiency, up to 90% Plug & Play Power - allows fast custom configuration - allow easy logistics Reduced system heat dissipation Few electrolytic capacitors (all long life) Visual LED indicators Series / Parallel of multiple outputs 5V bias standby voltage provided Individual output control signals
Xg2 Xg3
3.2 6.0 12.0 28.0 5.0
V1 V2
5.0 12.0 24.0 48.0 24.0 24.0 24.0
6.0 15.0 30.0 58.0 28.0 28.0 28.0
40A 20A 10A 6A 5A 3A 3A
200W 240W 240W 288W 120W 72W 72W
Xcite
* * * * * *
powerMods
MODEL Vmin Xg1 1.5 Vnom Vmax Imax 2.5 3.6 50A Watts 125W
powerPacs
MODEL XCA XCB XCC XCD Watts 400W 700W 1000W 1200W
APPLICATIONS INCLUDE
* * * * * * Industrial machines Test and measurement Automation equipment Printing Telecommunications For Medical applications see Xvite
Xg4 Xg5 Xg7 Xg8
5.0 5.0
EFFICIENCY (typical)
93 92 91
MECHANICAL SPECIFICATIONS
1
Third angle projection 50.00 46.00 23.50 19.00 80.00 TOP VIEW 19.00 19.00 127.00
J1
INPUT AC 100V-240V 50/60Hz SEE INSTRUCTION MANUAL 70C MAX OPERATING TEMPERATURE
97.75 122.00 92.00 SLOT F SLOT E SLOT D SLOT C SLOT B
Efficiency %
90 89 88 87 86 85 84 70 85 100 115 130 145 160 175 Line Voltage VAC 190 205 220 235 260
23.50
J2
SLOT A
40.40
29.50
All dimensions in mm. Mounting Holes 4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series
Fleximount Side Mounting Slots Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
400W-1200W AC/DC Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Input Voltage Range Input Frequency Range Power Rating XCA XCB XCC XCD Input Current XCA XCB XCC, XCD Inrush Current Undervoltage Lockout Fusing XCA XCB XCC, XCD Conditions/Description Universal Input Min 85 120 47 Nom Max 264 380 63 400 700 1000 1200 Units VAC VDC Hz W W W W A A A A VAC
Standard
2
Derate linearly from 1000W at 100VAC to 850W at 85VAC Derate linearly from 1200W at 120VAC to 850W at 85VAC 85VAC in 400W out 85VAC in 700W out 85VAC in 850W out 230VAC @ 25C Shutdown 250V 250V 250V Conditions/Description As per powerMod table Manual: Multi-turn potentiometer. As per powerMod table Electronic: See Xgen Designers' Manual For 10% change from nominal line For 25% to 75% load change For 25% to 75% load change Voltage Deviation Settling Time 20MHz Bandwidth 1st level: Vset Tracking. 2nd level: Vmax (Latching) Straight line with hiccup activation at <30% of Vnom See Designer's Manual for full details Max. line drop compensation. (except Xg7, Xg8) From AC In / Enable signal Monotonic For nominal output voltages at full load. XCA,XCB,XCC / XCD Output to Output / Output to Chassis Conditions/Description Input to Output Input to Chassis 230VAC, 1200W @ 24V EN60950, UL60950, CSA22.2 No.950 UL File No. E181875 250VAC, 60Hz, 25C See Xgen Series datasheet Always ON. Current 250mA Failures per million hours at 25C and full load powerMod See Designers' Manual. powerPac excludes fans powerPac Standard EN55011, EN55022, FCC EN55011, EN55022, FCC EN61000-3-2 EN61000-3-3 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-11 (EN55024) Conditions/Description
7.5 9.5 11.5 65 F8A HRC F10A HRC F12A HRC Min Nom Max 25 74
OUTPUT
Parameter powerMod Power Output Adjustment Range Minimum Load Line Regulation Load & Cross Regulation Transient Response Ripple and Noise Overvoltage Protection Overcurrent Protection Remote Sense Overshoot Turn-on Delay Rise Time Hold-up Time Output Isolation Units
0 0.1 0.2 10 250 1.0 125 120 0.5 2 300 / 30 5 20 / 15 500 / 500 Min 3000 1500 Nom Max
110 110
A % % % s % pk-pk % %. VDC % ms ms ms VDC Units VAC VAC % mA VDC fpmh fpmh Units
GENERAL
Parameter Isolation Voltage Efficiency Safety Agency Approvals Leakage Current Signals Bias Supply Reliability
90 1.5 4.9 5.0 5.1 1.0 0.6
EMC
Parameter Emissions Conducted Radiated Harmonic Distortion Flicker and Fluctuation Immunity Electrostatic Discharge Radiated RFI Fast Transients - burst Input Line Surges Conducted RFI Voltage Dips Level Level B Level B Compliant Compliant Level 4 Level 3 Level 4 Class 4 10 10 Min -20 -40 5 10 Nom Max +70 +85 95 200
V/m ms Units C C %RH Hz
ENVIRONMENTAL
Parameter Operating Temperature Storage Temperature Derating Relative Humidity Shock Vibration
1.6% per C above 40C. See Designers Manual for full deratings Non-condensing 3000 Bumps, 10G (16ms) half sine 1.5G
NOTES
1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel. 2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice. 3. All specifications at nominal input, full load, 25C unless otherwise stated. Doc. 40032 rev. 05 08/07 Europe/Asia Excelsys Technologies Ltd 27 Eastgate Drive Eastgate Business Park Little Island, Cork, Ireland IRELAND North America t: +353 21 4354716 Excelsys Technologies f: +353 21 4354864 519 Interstate 30, #309 e: sales@excelsys.com Rockwall, TX 75087 USA t: (972) 771 4544 f: (972) 421 1805 e: salesusa@excelsys.com


▲Up To Search▲   

 
Price & Availability of XCD

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X