If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
622 Mbps Single Mode Transceiver C-13-622-T(3)-SFC Features * FC Duplex Single Mode Transceiver * Industry Standard 1x9 Footprint * Complies with SONET OC-12 SDH STM-4 * Single +3.3V/+5V Power Supply * OperatingTemperature Range: 0 to 70C * LVPECL/PECL Differential Inputs and Outputs * LVPECL/PECL Signal Detection Output * Wave Solderable and Aqueous Washable * Uncooled laser diode with MQW structure * Complies with Telcordia (Bellcore) GR-468-CORE * SONET OC-12 Application * RoHS compliance available Absolute Maximum Rating Parameter Power Supply Voltage Power Supply Voltage Output Current Soldering Temperature Storage Temperature Symbol Vcc Vcc Iout - Min. 0 0 0 -40 Max. 3.6 6 30 260 85 Unit V V mA C C C-13-622-T3-SFC C-13-622-T-SFC Note 10 seconds on leads only Tstg Recommended Operating Condition Parameter Power Supply Voltage Power Supply Voltage Operating Temperature (Case) Data Rate Symbol Vcc Vcc Topr - Min. 3.1 4.75 0 - Typ. 3.3 5 622 Max. 3.5 5.25 70 - Unit V V C Mbps C-13-622-T3-SFC C-13-622-T-SFC Note Transmitter Specifications Parameter Optical Optical Transmit Power Optical Transmit Power Output center Wavelength Output Spectrum Width Extinction Ratio Output Eye Optical Rise Time Optical Fall Time Relative Intensity Noise Total Jitter Symbol Po Po p rms ER tr tf RIN TJ Min -15 -3 1274 8.2 - Typical 1310 - Max -8 +2 1356 2.5 1.2 1.2 -120 0.55 Unit dBm dBm nm nm dB ns ns dB/Hz ns RMS() C-13-622-T(3)-SFC Notes C-13-622-T(3)-SFC4 Compliant with ITU-T G.957/STM-4 Eye Mask 10% to 90% Values 10% to 90% Values Measured with 223-1 PRBS with 72 ones and 72 zeros. LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 1 LUMNDS802-Oct1606 Rev. A.2 622 Mbps Single Mode Transceiver C-13-622-T(3)-SFC Transmitter Specifications Parameter Electrical Power Supply Current Data Input Current-Low Data Input Current-High Differential Input Voltage Data Input Voltage-Low Data Input Voltage-High Symbol ICC IIL IIH VIH-VIL VIL-VCC VIH-VCC Min -350 300 -2.0 -1.1 Typical - Max 180 350 -1.58 -0.74 Unit mA A A mV V V Notes Maximum current is specified at Vcc= Maximum @ maximum temperature These inputs are compatible with 10K, 10KH and 100K ECL and PECL inputs Receiver Specifications Parameter Optical Sensitivity Maximum Input Power Signal Detect-Asserted Signal Detect-Deasserted Signal Detect-Hysteresis Wavelength of Operation Symbol Pin Pa Pd Min -3 -40 1 1100 Typical - Max -28 -28 5 1600 Unit dBm dBm dBm dBm dB nm Notes Measured with 223-1 PRBS,BER= 10-10 Measured on transition: low to high Measured on transition: high to low Receiver Specifications Parameter Electrical Power Supply Current Data output Voltage-Low Data Output Voltage-High Signal Detect Output Voltage-Low Signal Detect Output Voltage-High Symbol ICC VOL -Vcc VOH- Vcc VSDL-Vcc VSDH- Vcc Min -2 -1.1 -2.0 -1.1 Typical - Max 100 -1.58 -0.74 -1.58 -0.74 Unit mA V V V V Note The current excludes the output load current These outputs are compatible with 10K, 10KH and 100KECL and PECL outputs LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 2 LUMNDS802-Oct1606 Rev. A.2 622 Mbps Single Mode Transceiver C-13-622-T(3)-SFC Connection Diagram 1. (Rx GND) 2. (Rx +) 3. (Rx-) 4. (SD) 5. (Rx Vcc) 6. (Tx Vcc) 7. (TX-) 8. (TX+) 9. (Tx GND) NC Top View NC Receiver Signal Ground Receiver Data Out Receiver Data Out Bar Signal Detect Receiver Power Supply Transmitter Power Supply Transmitter Data In Bar Transmitter Data in Transmitter Signal Ground PIN 1 2 3 4 5 6 7 8 Warnings 9 Symbol RxGND RD+ RDSD RxVcc TxVcc TDTD+ TxGND Notes Directly connect this pin to the receiver ground plane See recommended circuit schematic See recommended circuit schematic Active high on this indicates a received optical signal DC power for the receiver section DC power for the transmitter section See recommended circuit schematic See recommended circuit schematic Directly connect this pin to the transmitter ground plane LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 3 LUMNDS802-Oct1606 Rev. A.2 622 Mbps Single Mode Transceiver C-13-622-T(3)-SFC Recommended Circuit Schematic C-13-622-T(3)-SFC Tx Vcc C5 Rx Vcc 98 R1 R3 765 432 1 R9 R5 R7 C6 TD + TD - RD + RD - Tx Vcc Rx Vcc R2 R4 SD R10 No internal connection Transceiver Top view No internal connection R6 R8 L1 Notes +3.3V: R1=R3=R5=R7=R9=130 R2=R4=R6=R8=R10=82 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H Notes +5V: R1=R3=R5=R7=R9=82 R2=R4=R6=R8=R10=130 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H Vcc C3 L2 C4 C1 Rx Vcc C2 Tx Vcc The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc. A GND plane under the module is required for good EMI and sensitivity performance. LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 4 LUMNDS802-Oct1606 Rev. A.2 622 Mbps Single Mode Transceiver C-13-622-T(3)-SFC Package Diagram Top View Front View Units: mm Side View Rear View LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 5 LUMNDS802-Oct1606 Rev. A.2 622 Mbps Single Mode Transceiver C-13-622-T(3)-SFC Ordering Information Available Options: C-13-622-T3-SFC C-13-622-T-SFC C-13-622-T3-SFC-G5 C-13-622-T-SFC-G5 C-13-622-T3-SFC4 C-13-622-T-SFC4 C-13-622-T3-SFC4-G5 C-13-622-T-SFC4-G5 Part unmbering Definition: C - 13 - 622 - T(3) - S FC Tx Power -RoHS * Wavelength 13= 1310 nm * Communication protocol (622 Mbps) * T3 = +3.3V Transceiver, FP T = +5V Transceiver, FP * Single mode fiber * Connector options * Tx Power range Blank = -15 to -8 dBm 4 = -3 to +2 dBm * Ordering Information Blank = RoHS non-compliant product G5 = RoHS 5/6-compliant product (lead exemption) LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 6 LUMNDS802-Oct1606 Rev. A.2 622 Mbps Single Mode Transceiver C-13-622-T(3)-SFC Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC's sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company's standard one-year warranty; however, specifications designated as "preliminary" are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company's Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN "AS IS" BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. (c) LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. * Chatsworth, CA 91311 * tel: 818.773.9044 * fax: 818.576.9486 9F, No 81, Shui Lee Rd. * Hsinchu, Taiwan, R.O.C. * tel: 886.3.5169222 * fax: 886.3.5169213 7 LUMNDS802-Oct1606 Rev. A.2 |
Price & Availability of C-13-622-T-SFC4-G5
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |